MAURY USCG vessel records
← All vessels

JOSE DO PATROCINIO

JOSE DO PATROCINIO is a 2015 tank ship. The Coast Guard has recorded 4 inspections since 2019, most recently in September 2023, along with 5 deficiencies.

Records from 2019 to 2023. Most recent: inspection, 1 September 2023.

Built
2015
Last inspected
1 September 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 September 2023
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2019–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9453860
1525909
Flag
BRAZIL
Maury page id
psix-1525909

Documentation record

Tonnage as PSIX records it81429 - Convention (Subpart B), Gross Ton
83075 - Regulatory (Subpart C or D), Gross Ton
50978 - Convention (Subpart B), Net Ton
72156 - Regulatory (Subpart C or D), Net Ton
156726 - Dead Weight, Metric Ton
182650 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

4 inspections, each with its date, unit and type; 5 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

1 September 2023 PSC B · COC-TVE Renew
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7777794
14 February 2022 COC-TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7395975
7 October 2020 PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7070067
3 May 2019 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6669965

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 1 September 2023 Resolved
74SOLAS(20)II-2/7.3.1.3 The Fire Damper shall operate automatically but shall be capable of being closed manually from both sides of the division. PSCO observed fire damper for emergency generator was unable to be actuated either manually or automatically.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 September 2023
Resolution: Crew repaired fire dampers to the satisfaction of attending PSCO.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 September 2023 Resolved
74SOLAS(20)I/11 The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed control panel in fuel oil purifier room was secured with duct tape and rope, exposing electrical circuits on system with 440 voltage. A temporary repair for remote valve for aft peak tank was improperly installed.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 19 September 2023
Resolution: The panel was permanently repaired to the satisfaction of the attending surveyor. Additionally, a tag indicating that power had been disconnected from the panel was attached to the power button on the panel. See documents for class report.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 September 2023 Resolved
74SOLAS(2020ED)CH.II-2 REG 9.4.1.5.1 Fire doors shall be self-closing and capable of closing with an angle of inclination of 3.5 degrees opposing closure. PSCO observed multiple fire doors failed to close and latch.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 September 2023
Resolution: The attending surveyor witnessed the automatic closing of all fire doors in way of the central staircase within the deckhouse. All automatically closing doors were demonstrated to fully close and latch to the satisfaction of the attending surveyor.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 September 2023 Resolved
74SOLAS(2020ED)CH.II-2REG14.1.1 Fire extinguishers shall be readily available. PSCO observed mulitple fire monitors not oerpational.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 September 2023
Resolution: Crew made repairs and tested fire monitors to the satisfaction of attending PSCO.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 September 2023 Resolved
74SOLAS(2020ED)CH.II-2REG14.2.1.1.1.3 The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs, means of escape systems and appliances. PSCO observed in aft steering, escape harness improperly connected.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 1 September 2023
Resolution: Crew removed Zip-tie and properly installed escape harness properly to the satisfaction of attending PSCO.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.