MAURY USCG vessel records
← All vessels

TITAN

Built
2001
Last inspected
4 August 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 August 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8964604
WDH4910
Flag
UNITED STATES
Maury page id
psix-15265

Documentation record

Registered dimensions (L × B × D)150.7 ft × 40.0 ft × 13.0 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)150.7 ft × 40.0 ft × 13.0 ft
ITC tonnagegross 612 / net 224
BuilderBOLLINGER SHIPYARDS LOCK · LOCKPORT, LA, UNITED STATES · built 2001
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNIKISKI, AK
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 7 January 2026 · expires 31 January 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it612 - Convention (Subpart B), Gross Ton
96 - Regulatory (Subpart C or D), Gross Ton
224 - Convention (Subpart B), Net Ton
65 - Regulatory (Subpart C or D), Net Ton
541 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 27 inspections, each with its date, unit and type; 51 deficiencies with the resolution recorded against each, 3 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 27

4 August 2026 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8455435
14 May 2026 Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8373074
13 March 2026 Drydock Exam · Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8325893
9 March 2026 Damage Survey
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8323507
21 July 2025 Annual Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8189142
22 October 2024 Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8022986
9 June 2024 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7931202
20 May 2024 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7903628
13 July 2023 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7745328
5 December 2022 Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7604596
22 August 2022 Type not recorded
No type recorded · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7560605
27 July 2022 Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7512836
15 December 2021 Type not recorded
No type recorded · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7368805
14 December 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7368274
18 October 2021 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7335135
8 September 2021 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7307382
26 July 2021 Examination of Repairs · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7263486
22 January 2021 Administrative Inspection
Administrative · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7134408
20 July 2020 Annual Inspection · Administrative Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7129190
28 January 2020 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6898008
14 June 2019 MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6742057
29 January 2019 Examination of Repairs · Plan Review (Other than "T") · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6616475
22 April 2018 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6430886
26 December 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6328927
6 June 2017 Internal Structural Exam · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6173815
28 April 2017 Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6242570
14 April 2016 MTSA Verification · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5848162

Deficiency record · 51

04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 August 2026 No resolution recorded
E-lighting in forward part of ER was out. Ensure emergency lighting provides adequate lighting along escape route.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2026 No resolution recorded
Ensure wiring for heater located in the overhead at the bottom of the ER ladder is properly mounted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2026
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 June 2026 No resolution recorded
Rig Pot Water Tank 1S - there are 02 insets on the fwd BHD, crop and renew at next scheduled drydock.
Action required: 705 - Other - as specified
16 - International Ship & Port Facility Security (ISPS) › N/A - No Subsystem › Security drills
Issued 21 July 2025 Resolved
Provide documentation of completing annual company security exercise with in the last year.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 22 July 2025
Resolution: all sat
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 July 2025 Resolved
Fix emergency light in emergency exit pointing at vertical ladder to main deck
Action required: 10 - Deficiency Rectified
Due 21 August 2025
Resolved 21 July 2025
Resolution: all sat
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 21 July 2025 Resolved
Replace all missing and expired in all first aid kits, burn kits and eye wash stations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2025
Resolved 6 August 2025
Resolution: all sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 July 2025 Resolved
Replace all expired Life ring bouy light batteries in both bridge wing life ring lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2025
Resolved 6 August 2025
Resolution: all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 July 2025 Resolved
find and repair exhaust leak on starboard main engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2025
Resolved 6 August 2025
Resolution: all sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 21 July 2025 Resolved
Adjust both engine room water tight door to make them water tight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2025
Resolved 7 August 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 June 2024 Resolved
Vessels with installed locks on the crew cabins must have a master key control plan. 46USC3106
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 9 July 2024
Resolution: Vsl installed door knobs without locks.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 13 June 2024 Resolved
Ensure the accuracy of the deviation table.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 9 July 2024
Resolution: Master provided objective evidence that vessel deviation table is correct.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 June 2024 Resolved
Ensure life rings are marked with the vessel name.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 9 July 2024
Resolution: marked
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 13 June 2024 Resolved
(a) Except as provided by paragraph (b) of this section, cranes, if installed, must comply with §§ 107.258 through 107.260, 108.601, 109.437, 109.439, 109.521, 109.525, and 109.527 of this chapter. (b) The manufacturer of a crane may have tests and inspections conducted in compliance with § 107.259 of this chapter, if the surveyor conducting them for the American Bureau of Shipping or the International Cargo Gear Bureau certifies their conduct as required by § 107.259(c) of this chapter. There were no test records for the crane.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 22 October 2024
Resolution: received cert
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 June 2024 Resolved
A vessel of less than 100 gross tons must have adequate emergency lighting fitted along the line of escape to the main deck from accommodations and working (machinery) spaces below the main deck. The mess deck and engine room did not have adequate emergency lighting.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 31 July 2024
Resolution: Additional e-lighting installed
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 13 June 2024 Resolved
Ensure the station bill accurately reflects the crew.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 26 August 2024
Resolution: rcvd station bill for 03 POB
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 13 June 2024 Resolved
Repair engine room ventilation closures, latches are frozen and broken
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 9 July 2024
Resolution: repaired
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 13 June 2024 Resolved
Label Emergency fuel shut off valves
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 9 July 2024
Resolution: labeled
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 13 June 2024 Resolved
Provide proper, functional tools to close emergency fuel shut off valves.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 20 August 2024
Resolution: vsl rep sent photo of remote valve closure tool
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 July 2023 Resolved
General alarm was not functional on emergency power.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2023
Resolved 31 July 2023
Resolution: Received video of alarm on e-power
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 July 2023 Resolved
Each ring life buoy waterlight must be fitted with the appropriate batteries as indicated on the approval label. Waterlights were fitted with the wrong batteries.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2023
Resolved 31 July 2023
Resolution: Received photos of correct batteries.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 July 2023 Resolved
Electrical boxes must not have openings to prevent shock. Provide blanks on electrical boxes on 02 deck aft.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2023
Resolved 31 July 2023
Resolution: Received photos of plugs
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 July 2023 Resolved
Vessel is endorsed as a stanby vessel and there are no search lights. Install 02 search lights or request to remove standby vessel endorsement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2023
Resolved 31 July 2023
Resolution: Removed standby vessel endorsement at request of vsl rep.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 July 2023 Resolved
Vessel is endorsed as a standby vessel and required a stokes litter. Vessel did not have a stokes litter on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2023
Resolved 31 July 2023
Resolution: Removed standby vessel endorsement at request of vsl rep.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 July 2022 Resolved
Each vessel must be designed and constructed to minimize fire hazards, as far as reasonable and practicable. Vessel needs to remove running portable heater and electrical cord under wooden pallet in plastic fish tote being used for line locker.
Action required: 10 - Deficiency Rectified
Due 28 July 2022
Resolved 28 July 2022
Resolution: all sat
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 July 2022 Resolved
prove proper operation of Starboard Bridge wing emergency light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2022
Resolved 1 August 2022
Resolution: all sat
16 - International Ship & Port Facility Security (ISPS) › N/A - No Subsystem › Security drills
Issued 28 July 2022 Resolved
Provide a copy of the last Annual Security Exercise conduct with in the last year or conduct an annual exercise with the Comapany.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2022
Resolved 1 August 2022
Resolution: all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 July 2022 Resolved
Find and repair exhaust leak on Port main.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2022
Resolved 9 August 2022
Resolution: all sat
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 28 July 2022 Resolved
provide current list of all vessel crew members enrolled in DAPI program at show current Titan Crew members are enrolled with in 7 days.
Action required: 705 - Other - as specified
Due 3 August 2022
Resolved 1 August 2022
Resolution: all sat
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 28 July 2022 Resolved
during next dry-dock renew all fuel shutoff valves for port and starboard #2 and #3 tanks.
Action required: 705 - Other - as specified
Due 30 June 2024
Resolved 4 June 2024
Resolution: Reach rods renewed
14 - Pollution Prevention › 141 - MARPOL Annex I › Pollution report-MARPOL Annex I
Issued 15 December 2021 Resolved
The vessel operator of each vessel required to have transfer procedures shall maintain them current and shall require vessel personnel to use the transfer procedures for each transfer operation. The transfer procedures where not followed while filling the port side day tank. There was no crew present, on deck, during the transfer. This resulted in the discharge of diesel into Cook Inlet.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 15 December 2021
Resolved 15 December 2021
Resolution: MI emphasized the importance of following transfer procedures.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 8 September 2021 Resolved
Prove proper operation of all emergency fuel oil shutoff valves on deck.
Action required: 10 - Deficiency Rectified
Due 7 October 2021
Resolved 7 October 2021
Resolution: Vessel got all fuel shutoff valves working
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 September 2021 Resolved
Replace Ring buoy line and ring buoy light line on port bridge wing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2021
Resolved 18 October 2021
Resolution: renewed
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 September 2021 Resolved
Prove proper operation of Emergency lighting in mid tunnel light
Action required: 10 - Deficiency Rectified
Due 7 October 2021
Resolved 7 October 2021
Resolution: Vessel replaced Batties and bulb
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 September 2021 Resolved
Install Plug in fuel filter drain for fwd center Hyd. Engine.
Action required: 10 - Deficiency Rectified
Due 7 October 2021
Resolved 7 October 2021
Resolution: Vessel found and installed plug
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 8 September 2021 Resolved
Prior to filling and using both #1 fuel tanks prove proper operation of the fuel shutoff valves
Action required: 705 - Other - as specified
Due 7 October 2021
Resolved 5 December 2022
Resolution: The vessel has received multiple satisfactory USCG inspections.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 21 July 2020 Resolved
Provide emergency lighting in berthing area near mess deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 3 August 2020
Resolution: Emergency lighting installed and tested.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 July 2020 Resolved
Provide a paint locker to stow all hazmat containers onboard wiht a 40-B portable fire extinguisher mounted near the locker or if locker is 60 cu ft or greater in volume, a fixed fire extinguishing system must be installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 3 August 2020
Resolution: Paint locker and fire extinguisher installed
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 July 2020 Resolved
Complete spot weld repairs on hull as determined during underwater dive survey completed July 20-21, 2020.
Action required: 705 - Other - as specified
Due 20 September 2020
Resolved 7 August 2020
Resolution: Underwater weld complete, observed via video feed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 30 January 2019 Resolved
Washed out welds and pitting was found on port and starboard side shell below water line, bottom plating and weld seams around keel coolers and rudder posts. Have gauging completed in areas of excessive pitting on plates. Identify source of electrolysis. Submit repair proposal to identify plate replacement and seam weld repairs.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2019
Resolved 12 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 April 2018 Resolved
MI found non marine grade electrical cable in vessel's workshop.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 May 2018
Resolution: Vessel removed equipment that electrical cable was using.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 23 April 2018 Resolved
Vessel must label remote fuel shut offs and have ready tool to secure on deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 May 2018
Resolution: Vessel stenciled shutoffs and installed tool on main deck for closure.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 April 2018 Resolved
Vessel must replace 3 lifejackets.
Action required: 705 - Other - as specified
Resolved 23 April 2018
Resolution: Vessel replaced three lifejackets on site during inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 23 April 2018 Resolved
Vessel's E/R emergency escape hatch was not sealing properly. Vessel must adjust and chalk test.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 May 2018
Resolution: Vessel adjsuted and conducted satisfactory chalk test.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 7 June 2017 Resolved
Provide repair proposal for approval and make permanent repairs to mud tank bulkhead cracks as discussed and marked. Cracks appeared at side long to transverse bulkhead attachment points.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 18 July 2017
Resolution: Drill stopped, Veed and welded.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 7 June 2017 Resolved
Provide repair proposal and make permanent repairs to leaking Port Ballast Tank #3 aft bulkhead iwo potable water tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 26 June 2019
Engineering › Compressed Air System (start air) › Valve
Issued 7 June 2017 Resolved
Prove proper operation of the port main engine start air system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 24 May 2018
Resolution: Verified proper operation of port M/E through testing and start up using PSTPs.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 7 June 2017 Resolved
Prove proper operation of the Port Generator overspeed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 24 May 2018
Resolution: Verified Testing f port generator overspeed.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 7 June 2017 Resolved
Provide non conductive matting in front of engine room switchboard and 460/480V panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 23 April 2018
Resolution: Verified non conductive matting was installed properly on electrical switchboard.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 7 June 2017 Resolved
Provide current corrected copy of fire control plan to USCG for approval.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 11 February 2019
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 7 June 2017 Resolved
Remove excess oily water from bilges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 24 May 2018
Resolution: Verified that oily waste from bilge was properly removed and excess bilge water was removed from below emergency escape hatch.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 14 April 2016 Resolved
Reinstall emergency lighting in Engine room for adequate illumination.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 27 October 2016
Resolution: E-light was re-mounted in a better location

Recorded names · 1

M/V JEAN GILBERT (2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.