This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it62330 - Convention (Subpart B), Gross Ton 36150 - Convention (Subpart B), Net Ton 115643 - Dead Weight, Metric Ton 135023 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 5
2 September 2022PSC B · COC-TVE Annual
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7547249
19 September 2021In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7315300
19 July 2021Administrative Inspection · PSC B · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7250809
11 September 2020COC-TVE Annual
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7045701
7 June 2019Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6703360
All the steering gear components shall be of sound and reliable construction to the satisfaction of the administration. During outbound transit, vessel experienced a loss of steering due to a faulty magnetic contactor, UMC 225, for th #1 steering gear motor. Vessel's crew was able to replace faulty parts with spares. PSCO tested steering from steering gear room and navigation bridge. All satisfactory.
74 SOLAS (20) II-1/29.2.1
Action required: 10 - Deficiency Rectified
Resolved 19 September 2021
Resolution: Burned out electrical connectors were replaced with spares that were kept on board and satisfactorily tested by attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 July 2021Resolved
NO ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN ANY SPACE WHERE FLAMMABLE MIXTURES ARE LIABLE TO COLLECT, UNLESS THE ADMINISTRATION IS SATISFIED THAT SUCH EQUIPMENT IS APPROPRIATELY CERTIFIED FOR SAFE USAGE IN THE DUSTS, VAPORS, OR GASES LIKELY TO BE ENCOUNTERED. PSCO OBSERVED MULTIPLE SENSORS ON CARGO AND BALLAST PUMPS INEFFECTIVELY SEALED.
74 SOLAS (20) II-1/45.10.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 July 2021
Resolved 21 July 2021
Resolution: ABS inspected that electrician properly sealed the sensor housings with electricians putty.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 July 2021Resolved
OIL TANKERS OF 20,000 TONNES DEADWEIGHT AND ABOVE, CONSTRUCTED ON OR AFTER 1 JANUARY, 2012 SHALL BE PROVIDED WITH A FIXED HYDROCARBON GAS DETECTION SYSTEM COMPLYING WITH THE FSS CODE FOR MEASURING HYDROCARBON GAS CONCENTRATIONS IN ALL BALLAST TANKS. WBT FIXED GAS DETECTION SYSTEM INOPERABLE.
74 SOLAS (20) II-2/4.5.7.3.1
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 19 July 2021
Resolved 21 July 2021
Resolution: Technician replaced vacuum and pressure switches and sealed air leaks clearing the flow fault.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.