SUPERIOR GUIDANCE is a 1977 offshore supply vessel. The Coast Guard has recorded 31 inspections since 1990, most recently in August 2018, along with 20 deficiencies and 1 casualty investigation in 2013.

Records from 1990 to 2018. Most recent: inspection, 23 August 2018.

Built
1977
Last inspected
23 August 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA5237
153183
Flag
UNITED STATES
366817950 (licence lapsed)
Maury page id
psix-153183

Inspections, by type

…with no type recorded2
Years with a record 22 calendar years (1990–2018)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it45 - Regulatory (Subpart C or D), Gross Ton
40 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDA5237MMSI 366817950 · expired · compulsorily equipped · granted 16 July 2011, cancelled 9 October 2021
WCP4381MMSI not assigned · expired · compulsorily equipped · granted 1 February 1999, cancelled 19 February 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPT JIMMY Commercial Fishing Vessel · MISLE 149569 · 9 June 1994 · activity 72001CAJUN MOON Passenger (Inspected) · MISLE 203382 · 28 August 1993 · activity 150249

Inspection history · 31

23 August 2018 Administrative Inspection
Administrative · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6634839
19 April 2016 Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5853635
2 February 2012 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4234501
29 August 2011 COI Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4126087
1 February 2011 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3937045
22 March 2010 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3698739
9 October 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3339504
22 July 2008 Internal Structural Exam · Re-Inspection · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3335494
27 July 2007 Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3000750
18 August 2006 Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2749947
16 May 2006 Internal Structural Exam · Hull Examination · Examination of Repairs · Damage Survey · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2650636
19 April 2005 COI Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2337434
19 February 2003 Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1746638
12 October 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457017
31 March 2000 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421832
9 August 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446815
14 May 1998 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1372244
18 September 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1407967
14 June 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460878
28 April 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1080141
3 January 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1187983
1 March 1995 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385379
4 January 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 856479
9 June 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 72001
18 March 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1374041
28 August 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 150249
29 June 1993 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448442
5 March 1992 COI Inspection · Inclining Experiment
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1264855
8 April 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1213175
1 November 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1215980
16 January 1990 Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 917048

Deficiency record · 20

Documentation › Certificates/Documents › Stability Letter
Issued 19 April 2016 Resolved
Ops manual approval date and stability letter approval dates do not line up. Update documentation to reflect proper dates.
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 25 April 2016
Resolution: Manual updated to reflect Stability letter.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 19 April 2016 Resolved
Mounting bracket on bridge fire extinguisher is missing latch. Will not secure.
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 25 April 2016
Resolution: Proper bracket installed.
Engineering › Steering Gear System › Trick Wheel
Issued 29 August 2011 Resolved
Prior to 24Feb2012 degisn and install a secondary means of steering IAW 46CFR 182.30. Contact [phone withheld] when completed and ready for examination.
Action required: 705 - Other - as specified
Due 24 February 2012
Resolved 2 February 2012
Resolution: Tested aux steering system, test SAT.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 22 March 2010 Resolved
Vessel master must provide a waste management plan
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 24 January 2012
Documentation › Logs/Records › Logbook (official)
Issued 22 March 2010 Resolved
Vessel master must log safety equipment maintenance and pre-departure checklist.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 24 January 2012
Stability › Watertight Integrity › Coaming
Issued 22 July 2008 Resolved
Engine room hatches need to replace soft rubber gasket with hard rubber gasket.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2008
Resolution: New gaskets put into hatch covers.
Construction/Loadline › Structures › Scuttle
Issued 22 July 2008 Resolved
Stbd side E/R emergency escape scuttle doesn't shut properly allowing light to come through, scuttle needs to be repaired or replaced.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2008
Resolution: Escape scuttle was replaced with a properly working one.
Operations/Management › Drills/Instruction › Not Conducted
Issued 22 July 2008 Resolved
Vessel has been laid up since the summer time and has not conducted drills. A round of drills need to be conducted and logged prior to commencing operations.
Action required: 705 - Other - as specified
Due 24 December 2008
Resolved 2 December 2008
Resolution: Vessel rep conducted drills with crew and ensured logging prior to operations.
Construction/Loadline › Hull › Hull Plating
Issued 18 August 2006 Resolved
Weld an 18 x 18 inch insert aft at the transom on the stbd side of the leg to repair a small hole on the sideshell where the transom and deck meet.
Due 18 September 2006
Resolved 22 August 2006
Communications › Radio Communications › EPIRB
Issued 18 August 2006 Resolved
Provide proof that the EPIRB hydrostatic release has been replaced.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 August 2006
Resolved 22 August 2006
Navigation › Piloting/Steering
Issued 19 February 2003 Resolved
Provide updated compass deviation table. LEGACY COMPONENT DESC: Compass Deviation Table
Action required: 705 - Other - as specified
Due 20 February 2004
Resolved 20 January 2004
Resolution: Baker Lyman came out and swung the compass. Deviation table is up to date.
Lifesaving
Issued 9 August 1999 Resolved
Demonstrate compliance with the 8th U.S. Coast Guard's policy Ltr. "Rescue Boat Requirements on Offshore Supply Vessels" dated 12NOV98 to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Due 9 August 1999
Resolved 9 August 1999
Lifesaving
Issued 5 March 1992 Resolved
PROVIDE AN APPROVED RESCUE BOAT THAT MEETS 46 CFR 160.056. SEE _x001C_ 46 CFR 180.10-35.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Documentation
Issued 16 January 1990 Resolved
PROVIDE ON BOARD A COAST GUARD ISSUED STABILITY LETTER.
Condition: Unknown
Due 16 January 1990
Resolved 16 January 1990
Documentation
Issued 16 January 1990 Resolved
PROVIDE ON BOARD A ROUGH COPY OF OPERATING MANUAL MEETING THE APPLICABLE SECTIONS OF 46 CFR 109.121.
Condition: Unknown
Due 16 January 1990
Resolved 16 January 1990
Navigation
Issued 16 January 1990 Resolved
PROVIDE ON BOARD AN ALTERNATE MEANS OF STEERING.
Condition: Unknown
Due 16 January 1990
Resolved 16 January 1990
Unknown
Issued 16 January 1990 Resolved
PROVIDE DEAD MAN FEATURE FOR JACKING CONTROLS.
Condition: Unknown
Due 16 January 1990
Resolved 16 January 1990
Documentation
Issued 16 January 1990 Resolved
SUBMIT AN OPERATING MANUAL MEETING THE APPLICABLE SECTIONS OF 46 CFR 109.121 TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 16 January 1990
Resolved 16 January 1990
Construction/Loadline
Issued 16 January 1990 Resolved
PROVIDE COLLISION BULKHEAD IN ACCORDANCE WITH 46 CFR SUBCHAPTER "S".
Condition: Unknown
Due 16 January 1990
Resolved 16 January 1990
Documentation
Issued 16 January 1990 Resolved
SUBMIT PLANS SHOWING GENERAL ARRANGEMENT, INBOARD AND OUTBOARD PROFILE AND A STRUCTURAL ANALYSIS OF ALL LEGS AND LEG TOWER SUPPORTS TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 16 January 1990
Resolved 16 January 1990

Casualty record · 1

1 October 2013Routine · role: Involved in a Marine Casualty · activity 4727505
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.