MAURY USCG vessel records Sign in
← All vessels

VENTURE

VENTURE is a 1977 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 1999, most recently in March 2014, along with 109 deficiencies — 15 with no resolution recorded —.

Records from 1999 to 2014. Most recent: inspection, 25 March 2014.

Built
1977
Last inspected
25 March 2014
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD9157
153215
Flag
UNITED STATES
367307670 (licence lapsed)
Maury page id
psix-153215

Inspections, by type

…with no type recorded3
Years with a record 13 calendar years (1999–2014)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)48.8 ft × 21.1 ft × 5.2 ft
Registered tonnagegross 39 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEDWARD ATMANCHUK · NORTH ARLINGTON, NJ, UNITED STATES · built 1977
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portKEYPORT, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Net Ton
39 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD9157MMSI 367307670 · expired · compulsorily equipped · granted 10 August 2007, cancelled 14 October 2017
WCZ4193MMSI not assigned · expired · compulsorily equipped · granted 4 August 1999, cancelled 10 October 2009
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 21

25 March 2014 Welding Related Inspections Qualification Testing · Hull Examination · COI Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4822966
12 January 2012 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4223888
2 August 2011 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4110218
27 February 2009 COI Inspection · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3425055
2 July 2008 COI Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3254888
22 June 2007 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2970361
21 April 2005 Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2340231
19 July 2004 MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2137891
3 September 2003 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1895608
14 April 2003 MARPOL Annex V Examination · Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1771641
3 June 2002 Deficiency Check · MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1625608
17 August 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 730458
31 May 2001 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1445818
17 May 2001 Drydock Extension · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1393682
1 April 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 292991
7 June 2000 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1454824
11 February 2000 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1061118
11 June 1999 Inclining Experiment
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1372654
8 June 1999 Hull Examination · Initial Certification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1395202
2 June 1999 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1365332
5 April 1999 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1123035

Deficiency record · 109

Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 25 March 2014 No resolution recorded
46 CFR 181.500 Fire extinguishers must be properly mounted.
Action required: 701 - Prior to carriage of passengers/cargo
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 25 March 2014 Resolved
46 CFR 183.200: Remove or replace the power strip at the bar with an appropriate marine grade.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2014
Resolution: The power strip was removed.
Fire Fighting › Fire Hoses › Condition
Issued 25 March 2014 Resolved
46 CFR 181.320: Replace damaged fire hose.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2014
Resolution: The hose was replaced. New hose was inspected and was good.
Construction/Loadline › Structures › Superstructure
Issued 25 March 2014 No resolution recorded
46 CF 181.900(g): Deck rail opening greater than tolerated by regulations on the second deck and bow.
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Structures › Deck Plating
Issued 25 March 2014 No resolution recorded
46 CFR 179.360: Deck plating not weather tight. Screw down and re-caulk.
Action required: 701 - Prior to carriage of passengers/cargo
Electrical › Electrical Distribution System (service) › Switchboard
Issued 25 March 2014 No resolution recorded
46 CFR 183.330: Distribution panel on the first deck does not have 24 inches of clearance.
Action required: 701 - Prior to carriage of passengers/cargo
Electrical › Electrical Distribution System (service) › Switchboard
Issued 25 March 2014 No resolution recorded
46 CFR 183.330: Distribution panel on the first deck must have a non conductive mat.
Action required: 701 - Prior to carriage of passengers/cargo
Electrical › Electrical Distribution System (service) › Switchboard
Issued 25 March 2014 No resolution recorded
46 CFR 183.330: Distribution panel on the first deck must be properly labeled.
Action required: 701 - Prior to carriage of passengers/cargo
Fire Fighting › Fire Pumps › Arrangement
Issued 25 March 2014 No resolution recorded
46CFR181.300(e): Vessel did not have a remote start of the fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 25 March 2014 No resolution recorded
46 CFR 430(a): Missing lagging on engine exhaust for both port and starboard engines.
Action required: 701 - Prior to carriage of passengers/cargo
Electrical › Electrical Distribution System (service) › Panelboard
Issued 25 March 2014 No resolution recorded
46 CFR 183.330: Distribution panel front cover in Port Void #2 was completely rusted through. Replace
Action required: 701 - Prior to carriage of passengers/cargo
Documentation › Markings/Placards › Capacity Marking
Issued 25 March 2014 No resolution recorded
46 CFR 185.602(g): Need to adjust marked passenger count on the upper deck to new stability letter.
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Bilge Water Management System › Pump
Issued 25 March 2014 No resolution recorded
46 CFR 176.830(b): Engine room cleanliness, oil and debris in bilge
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Bilge Water Management System › Vent
Issued 25 March 2014 No resolution recorded
46 CFR 182.410: Hoses in starboard void #2 must be properly clamped.
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 25 March 2014 No resolution recorded
46 CFR 16: All of the crew has to be on the vessels DAPI program.
Action required: 701 - Prior to carriage of passengers/cargo
Communications › Public Address System › Broadcast Location
Issued 25 March 2014 No resolution recorded
Public address system could not be hear on the main deck.
Action required: 701 - Prior to carriage of passengers/cargo
Accommodation/Occupational Safety › Heating › Electric Air Heating Equipment
Issued 25 March 2014 No resolution recorded
46 CFR 181.200(b): Remove or fix the space heater w/ exposed wires behind the ships wheel.
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Hull › Bottom Plating
Issued 12 January 2012 Resolved
Vessel broke free from mooring and was aground IVO South Amboy. Must demonstrate no damage to hull, rudder, shaft, or engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2012
Resolution: Conducted hull exam, see activity # 4451229 for details.
Documentation › Logs/Records › Drug Test Records
Issued 2 August 2011 Resolved
Vessel must provide proof of current enrollment in DAPI for ship and crew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2011
Resolution: Provided proper paper work.
Engineering › Bilge Water Management System › Piping
Issued 2 August 2011 Resolved
Bilge suction in void #2 does not work, must fix system and prove operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2011
Resolution: Proved operation of bilge system.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 2 August 2011 Resolved
Vessel must fix port water exhaust leak in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2011
Resolution: Fixed leak
Engineering › Bilge Water Management System › Not Operational
Issued 2 August 2011 Resolved
Vessel must remove all water from bilge for proper inspection and keep dry as possible at all times.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2011
Resolution: Cleaned bilge as directed.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 2 August 2011 Resolved
Vessel must get new Coast Pilot and Light List.
Due 15 August 2011
Resolved 5 August 2011
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 27 February 2009 Resolved
Fix exhaust leak in engine room.
Action required: 705 - Other - as specified
Due 29 May 2009
Resolved 29 May 2009
Resolution: Owner has fixed exhaust leak which was caused by loose exhaust line.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 27 February 2009 Resolved
Relocate life jackets from pilot house to common area for passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2009
Resolution: Life jackets were removed from pilot house and located throughout common areas for passengers.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 27 February 2009 Resolved
Place donning placard for both types of lifejackets on main deck and upper deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2009
Resolution: Placards were place both on main and upper deck.
Construction/Loadline › Structures › Scuttle
Issued 22 June 2007 Resolved
Provide captive chains in way of all main deck access hatches.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2009
Resolution: All captive chains are in place
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 22 June 2007 Resolved
Make repairs to wasted lower rail course main deck, port bow.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2009
Resolution: Rail was v-notched and rewelded.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 June 2007 Resolved
Provide globe for fixed lighting starboard side tank space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2009
Resolution: Globe was provided for starboard side tank space.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 June 2007 Resolved
Remove plastic wire ties and properly support wires port side generator space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2009
Resolution: Proper wire ties were supplied for wires port side generator space.
Engineering › Freshwater System (jacketwater cooling) › Suction Strainer
Issued 22 June 2007 Resolved
Make generator raw water suction strainer ready for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2009
Resolution: Generator raw water suction strainer was inspected and found satifactory.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 22 June 2007 Resolved
Re-install flex hose connection iwo generator piping, port side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2009
Resolution: Flex hose connection IWO generator piping was re-installed.
Engineering › Bilge Water Management System › Valve
Issued 22 June 2007 Resolved
Replace wasted reach rod #2 void space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2009
Resolution: Reach rod #2 void space was fixed.
Fire Fighting › Fire Hoses › Condition
Issued 22 June 2007 Resolved
Replace fire hose main deck aft.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2009
Resolution: Fire hose was replaced with new.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 22 June 2007 Resolved
Provide servicing certificates for all portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2009
Resolution: All portable fire extinguishers were serviced.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 June 2007 Resolved
Provide globe for fixed lighting starboard side generator space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2009
Resolution: Globe in starboard gererator space was fixed.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 19 July 2004 Resolved
Provide\post current certificate of documentation.
Due 2 August 2004
Resolved 7 September 2004
Resolution: DOC provided to OCMI.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 19 July 2004 Resolved
Prove vsl Captain enrolled in DAPI Consortium
Due 2 August 2004
Resolved 7 September 2004
Resolution: Consortium registration form provided to OCMI.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 19 July 2004 Resolved
Prove proper operation of bilge pump prior to commercial ops.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 July 2004
Resolved 30 July 2004
Resolution: Replaced Fixed Bilge Pump with new.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 19 July 2004 Resolved
Provide current tide table, light list, & chart updates.
Due 19 August 2004
Resolved 22 July 2004
Resolution: Provided current tide table, light list, & updated charts.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 19 July 2004 Resolved
Replace retro tape on life jackets as needed.
Due 19 August 2004
Resolved 22 July 2004
Resolution: Replaced all retro-tape onto PFD''''s as required.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 19 July 2004 Resolved
Make life jackets in pilot house accessible.
Due 19 August 2004
Resolved 22 July 2004
Resolution: Replaced required amount of PFD''''s into pilot house & made accessible.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 July 2004 Resolved
Replace grab lines on pilot house life rings (2).
Due 19 August 2004
Resolved 30 July 2004
Resolution: Replaced life rings with new/approved type as required.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 19 July 2004 Resolved
Place vessle name on new life ring or remove from vsl.
Due 19 August 2004
Resolved 22 July 2004
Resolution: Placed vessel''''s name/homeport on the new/approved life rings.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 July 2004 Resolved
Provide 3 ft lanyard for each waterlight.
Due 19 August 2004
Resolved 30 August 2004
Resolution: Replaced lanyard with new in kind.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 July 2004 Resolved
Replace 60 ft lifeline for life rings.
Due 19 August 2004
Resolved 30 July 2004
Resolution: Replaced lifeline with required length of line.
Electrical › Electrical Distribution System (service) › Cable
Issued 19 July 2004 Resolved
Remove extension cords throughout vsl.
Due 19 August 2004
Resolved 30 August 2004
Resolution: Removed same.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 19 July 2004 Resolved
Install cover for outlet box 2nd deck, stern.
Due 19 August 2004
Resolved 30 August 2004
Resolution: Installed outlet box cover.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 19 July 2004 Resolved
Place vsl name/hailing port on stern.
Due 19 August 2004
Resolved 30 August 2004
Resolution: Placed vessels name/hailing port on stern of vessel as required.
Pollution Prevention/Response › Prevention Equipment › Means of Removal from within Coaming
Issued 19 July 2004 Resolved
Remove oily water from bilges.
Due 19 August 2004
Resolved 30 August 2004
Resolution: Removed oily water from bilges as required, (MARPOL V).
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 19 July 2004 Resolved
Provide override for fixed fire system.
Due 19 July 2004
Resolved 22 July 2004
Resolution: Provided proper override for vessel''s fixed CO2 firefighting system.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 19 July 2004 Resolved
Provide documentation for fixed fire system - "serviced"
Due 19 August 2004
Resolved 30 August 2004
Resolution: Vessel''s fixed CO2 firefighting system was inspected/documented/serviced as required.
Engineering › Bilge Water Management System › Not Operational
Issued 19 July 2004 Resolved
Prove proper operation of high level bilge alarms prior to commercial ops.
Due 19 July 2004
Resolved 22 July 2004
Resolution: All high level bilge alarms were inspected/operationally tested satisfactorily prior to commercial operations.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 19 July 2004 Resolved
Install insulation/lagging for stbd MDE & generator exhaust in lazarette.
Due 19 August 2004
Resolved 30 August 2004
Resolution: MDE/Generator exhaust lagging replaced as required.
Engineering › Bilge Water Management System › Not Operational
Issued 19 July 2004 Resolved
Post instructions to operate fire/bilge pump.
Due 19 August 2004
Resolved 30 August 2004
Resolution: Instructions to operated fire/bilge pump posted as required.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 July 2004 Resolved
Replace light cover in generator space.
Due 19 August 2004
Resolved 30 July 2004
Resolution: Light cover in generator space properly replaced as required.
Engineering › Bilge Water Management System › Strainer
Issued 19 July 2004 Resolved
Repair strainer on bilge in forepeak.
Due 19 August 2004
Resolved 30 July 2004
Resolution: Bilge strainer in forepeak space replaced as required.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 19 July 2004 Resolved
Secure hatch covers in voids #1 & 2.
Due 19 August 2004
Resolved 22 July 2004
Resolution: Hatch covers in voids 1 & 2 properly secured with chain as required.
Engineering › Bilge Water Management System › Not Installed
Issued 19 July 2004 Resolved
Porperly wire bilge high level alarms.
Due 19 August 2004
Resolved 30 August 2004
Resolution: Properly secured/wired high level bilge alarms.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 19 July 2004 Resolved
Replace stbd MDE exhaust cooling water hose.
Due 19 August 2004
Resolved 30 July 2004
Resolution: MDE S/S exhaust cooling hose replaced with new.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 July 2004 Resolved
Properly terminate/remove deadend wire in port MDE battery box.
Due 19 August 2004
Resolved 22 July 2004
Resolution: Properly terminated deadend wiring in P/S MDE battery box.
Engineering › Steering Gear System
Issued 17 April 2003 Resolved
Make permanent repair to cracked port rudder. LEGACY COMPONENT DESC: Rudder
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2003
Resolved 22 April 2003
Resolution: Port rudder had crack drill stopped and crack was welded.
Accommodation/Occupational Safety › Ventilation
Issued 17 April 2003 Resolved
Ventilate (mechanical) and determine source of strong ammonia smell from MSD space. MI did not enter space to conduct internal structural exam of this space. This items needs to be corrected prior to going back into water and inspected CG [name withheld] ventilated, attempt to ID source of problem.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2003
Resolved 22 April 2003
Resolution: Identified problem and repaired leaking MSD macerator pump packing.
Accommodation/Occupational Safety › Occupational Safety
Issued 17 April 2003 Resolved
Repair/secure fwd rail fencing at bottom where detached. LEGACY COMPONENT DESC: Deck Rail
Due 21 April 2003
Resolved 22 April 2003
Resolution: Damaged fencing replaced.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 17 April 2003 Resolved
Double clamp flex hoses for wet exhaust on P/S main diesel engines. LEGACY COMPONENT DESC: Piping (exhaust)
Due 21 April 2003
Resolved 22 April 2003
Resolution: Hoses double clamped.
Engineering › Sea-water System (primary cooling)
Issued 17 April 2003 Resolved
Double clamp all keel cooler flex hoses in E/R & gen rm. LEGACY COMPONENT DESC: Piping
Due 21 April 2003
Resolved 22 April 2003
Resolution: Double clamps installed.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 17 April 2003 Resolved
Replace missing exhaust lagging on P/S main diesel engines. LEGACY COMPONENT DESC: Piping (exhaust)
Due 21 April 2003
Resolved 22 April 2003
Resolution: All exhaust piping had lagging installed.
Accommodation/Occupational Safety › Occupational Safety
Issued 17 April 2003 Resolved
Secure grate landing at bottom of E/R ladder.
Due 21 April 2003
Resolved 22 April 2003
Resolution: Landing grate welded in place.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 17 April 2003 Resolved
Provide clamps & secure clamps on all flex exhaust elbow on MDEs (port/stbd). LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Unknown
Due 21 April 2003
Resolved 22 April 2003
Resolution: Clamps on exhaust elbows installed.
Electrical › Electrical Distribution System (service)
Issued 17 April 2003 Resolved
Secure electrical box cover in mens head behind toilet. LEGACY COMPONENT DESC: Junction Box
Due 21 April 2003
Resolved 22 April 2003
Resolution: Cover secured.
Electrical › Lighting (service)
Issued 17 April 2003 Resolved
Remove inoperable tube lighting (decorative) that does not work (not approved). LEGACY COMPONENT DESC: Lighting Fixture
Due 21 April 2003
Resolved 22 April 2003
Resolution: All tube lighting removed.
Accommodation/Occupational Safety › Occupational Safety
Issued 17 April 2003 Resolved
Remove flam paint & trash from maind deck storage room (electrical panel rm).
Due 21 April 2003
Resolved 22 April 2003
Resolution: All flammable materials and trash removed from space.
Engineering › Fuel Oil Service System
Issued 17 April 2003 Resolved
Fuel leaks from both shut off valves in fuel tank room. LEGACY COMPONENT DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2003
Resolved 22 April 2003
Resolution: Tightened valves, leaks stopped.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 17 April 2003 Resolved
Remove electric heater from bridge that doesn't work/not used.
Due 21 April 2003
Resolved 22 April 2003
Construction/Loadline › Hull
Issued 17 April 2003 Resolved
Provide repair proposal to address holes cut in main deck over engine room aft (accepted 18" x 30" insert). LEGACY COMPONENT DESC: Deck
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2003
Resolution: Vsl e-mailed picture of bolted flat bar with rubber gasket over holes as temp repair until heater is installed.
Accommodation/Occupational Safety › Occupational Safety
Issued 14 April 2003 Resolved
Remove/stow maintenance gear in generator compartment.
Due 21 April 2003
Resolved 22 April 2003
Resolution: All flammable material removed.
Documentation › Certificates/Documents
Issued 14 April 2003 Resolved
Post applicable certificates, COI, stability, emergency instructions. LEGACY COMPONENT DESC: Stability Letter
Condition: Unknown
Due 21 April 2003
Resolved 22 April 2003
Documentation › Logs/Records
Issued 14 April 2003 Resolved
Provide documentation that the vsl is enrolled in a Drug & Alcohol monitoring program. LEGACY COMPONENT DESC: Drug Test Records
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2003
Resolved 22 April 2003
Resolution: Documentation provided showing enrollment with The Maritime Consortium.
Documentation › Certificates/Documents
Issued 14 April 2003 Resolved
Provide charts for operating area. LEGACY COMPONENT DESC: Navigation Charts
Due 21 April 2003
Resolved 22 April 2003
Resolution: Charts provided for Lower Bay/Raritan Bay.
Lifesaving › Lifejacket/PFD (Type I)
Issued 14 April 2003 Resolved
Replace retro tape as needed on life jackets. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2003
Resolved 22 April 2003
Resolution: New retro tape applied to identified PFD''''s.
Documentation › Certificates/Documents
Issued 14 April 2003 Resolved
Provide up to date FCC Safety cert. LEGACY COMPONENT DESC: FCC Safety Radio Telephony Cert
Due 21 April 2003
Resolved 10 June 2003
Resolution: Rcvd fax copy.
Lifesaving › Lifebuoys
Issued 14 April 2003 Resolved
Repair/replace stbd life ring. LEGACY COMPONENT DESC: Grab Lines
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2003
Resolved 25 April 2003
Resolution: Received fax receipt for new 24" lifering.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 14 April 2003 Resolved
Prove overide of fire boy system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2003
Resolved 22 April 2003
Resolution: Tested during fire drill held on 22APR03, sat.
Engineering › Fuel Oil Service System
Issued 14 April 2003 Resolved
Address fuel leak on priming pump. LEGACY COMPONENT DESC: Pump
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2003
Resolved 22 April 2003
Resolution: Pump piping adjusted, leak stopped.
Personnel › Certificates/Documents/Licenses
Issued 14 April 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2003
Resolved 22 April 2003
Resolution: Licensed Master provided w/appropriate license.
Stability › Weathertight Integrity
Issued 14 April 2003 Resolved
Replace cracked bridge window.
Due 21 April 2003
Resolved 22 April 2003
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 April 2003 Resolved
Replace 60 ft of line on port ring buoy.
Due 21 April 2003
Resolved 22 April 2003
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 April 2003 Resolved
Conduct MOB drill to the satisfaction of a MI.
Due 14 April 2003
Resolved 22 April 2003
Operations/Management › Drug and Alcohol Testing
Issued 3 June 2002 Resolved
Prove enrollment in Drug and Alcohol program. Provide contract and post hotline numbers. LEGACY COMPONENT DESC: Proof of Enrollment
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 June 2002
Resolved 7 June 2002
Resolution: Witnessed proof of enrollment in DAPI program.
Fire Fighting › Fire Pumps
Issued 3 June 2002 Resolved
Prove proper operation of firepump and bilgepump. LEGACY COMPONENT DESC: Operation
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 June 2002
Resolved 7 June 2002
Resolution: Witnessed proper operation of pumps.
Documentation › Logs/Records
Issued 3 June 2002 Resolved
Provide record of monthly fire and man overboard drills. LEGACY COMPONENT DESC: Drills
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 August 2002
Resolved 30 October 2002
Resolution: Rcvd fax copy of vsl''s log indicating fire and man overboard drills.
Lifesaving › Hand Flares
Issued 3 June 2002 Resolved
Provide correct number of distress signalling devices (hand flares). LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 June 2002
Resolved 7 June 2002
Resolution: Witnessed correct number of distress signals.
Stability
Issued 3 June 2002 Resolved
Mark upper deck for maximum number of passengers per stability letter. LEGACY COMPONENT DESC: Upper Deck Limitation Marking
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 June 2002
Resolved 7 June 2002
Resolution: Examined satisfactory marking of upper deck.
Construction/Loadline › Structures
Issued 3 June 2002 Resolved
Provide securing chains for forward scuttles LEGACY COMPONENT DESC: Scuttle
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 June 2002
Resolved 3 June 2002
Resolution: Witnessed installation of chains.
Electrical › Electric Supply System (service)
Issued 3 June 2002 Resolved
Provide metal supports for cables in generator room (above compressor). LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 June 2002
Resolved 7 June 2002
Resolution: Witnessed install of metal supports.
Operations/Management › Drills/Instruction
Issued 3 June 2002 Resolved
Conduct u/w man overboard drill in the presence of USCG Inspector (Modified 30Oct02 by [name withheld] Must complete prior to carrying passengers). LEGACY COMPONENT DESC: Man Overboard Recovery
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 April 2003
Resolved 22 April 2003
Resolution: Satisfactory man overboard drill conducted.
Construction/Loadline
Issued 31 May 2001 Resolved
CLEAN GASKET AND MATING SURFACES ON ALL SCUTTLES. SCUTTLE DOGGING MECHANISMS REQUIRES MAINTENANCE.
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001
Engineering
Issued 31 May 2001 Resolved
CUTLASS BEARING REQUIRES REPLACEMENT.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Engineering
Issued 31 May 2001 Resolved
TIGHTEN 2 LOOSE BOLTS ON MDE'S. CHECK ALL FOR TIGHTNESS USING WRENCH.
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001
Documentation
Issued 1 April 2001 Resolved
Vessel was being operated beyond it's normal drydock period without an authorized extension required by 46 CFR 176.15-1(a).
Condition: Unknown
Due 31 May 2001
Resolved 17 August 2001
Documentation
Issued 8 June 1999 Resolved
Post documents in pilot house, ie; stability letter, COI, emergency radio braodcast placard, FCC certificate, Station License, Emergency instructions
Condition: Unknown
Due 26 July 1999
Resolved 26 July 1999
Documentation
Issued 8 June 1999 Resolved
Provide copy of newly formed company drug and alcohol program.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Navigation
Issued 8 June 1999 Resolved
Provide charts, light list, tide table, and tidal current tables.
Condition: Unknown
Due 26 July 1999
Resolved 26 July 1999
Fire Fighting
Issued 8 June 1999 Resolved
Provide hydrostatic test date and weight test date for newly installed [name withheld] Fyre Watch system.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Documentation
Issued 8 June 1999 Resolved
Provide photo copy of FCC Station License, and Safety Certificate upon reciept.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Electrical
Issued 8 June 1999 Resolved
Provide abraision protection for electrical service lines running through overhead above snack bar on main deck.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Lifesaving
Issued 8 June 1999 Resolved
Provide type II retroreflective tape for life ring bouy and a corrosion resistant clip for the floating water light.
Condition: Unknown
Due 26 July 1999
Resolved 26 July 1999
Construction/Loadline
Issued 2 June 1999 Resolved
SUBMIT PLANS, FOR REVIEW AND APPROVAL, FOR HIGH LEVEL BILGE ALARM SYSTEM.
Condition: Unknown
Due 25 September 1999
Resolved 26 August 1999
Electrical
Issued 2 June 1999 Resolved
SUBMIT REVISED ONE LINE ELECTRICAL DIAGRAM. ENSURE DIAGRAM MATCHES ACTUAL SYSTEM.
Condition: Unknown
Due 25 September 1999
Resolved 26 August 1999

Ownership record