← All vessels
PACIFIC YANTAI
PACIFIC YANTAI is a 2015 tank ship. The Coast Guard has recorded 12 inspections since 2018, most recently in April 2026, along with 2 deficiencies and 1 operational control.
Records from 2018 to 2026. Most recent: inspection, 18 April 2026.
- Built
- 2015
- Last inspected
- 18 April 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 2 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9739965 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
VRPO2
1535990
Flag
HONG KONG
—
Maury page id
psix-1535990
Inspections, by type
…with no type recorded1
Years with a record
8 calendar years (2018–2026)
The 12 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it48419 - Convention (Subpart B), Gross Ton
53999 - Dead Weight, Metric Ton
72807 - Displacement, Metric Ton
17391 - Convention (Subpart B), Net Ton
53999 - Dead Weight, Metric Ton
72807 - Displacement, Metric Ton
17391 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 12
18 April 2026
PSC B · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8350302
24 April 2025
Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 8123527
23 April 2025
PSC B · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8115581
4 November 2024
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8029228
21 February 2024
COC-GAS Renew · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7867216
13 February 2023
COC-GAS Annual · Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7636080
3 January 2022
PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7372173
5 October 2020
COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7069215
7 February 2019
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6621520
6 December 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6593026
16 November 2018
Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6579259
15 November 2018
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6581768
Deficiency record · 2
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 January 2022
Resolved
Lighting fittings should have pressurized enclosures or be of the flameproof type. PSCO observed one cracked light enclosure in the cargo compressor room and one in the cargo tank #4 area.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 16 November 2018
Resolved
Gas detection equipment acceptable to the Administration shall be provided.
Cargo Operations Manual, page 3-10 describes system as with catalytic sensor. Drawing no. 32630.GSS.02.01 pg 4 shows schematic of system with Consilium ST650EX HC/VCM gas detector. Drawing no. 32630.GSS.02.01 pg 2 says system has 2 pumps, 1 for analysis and 1 for dilution. This 2 pump arrangement is also shown on Drawing no. 32639.GSS.03.01 pg 2.
The actual system fitted onboard has only an analyzing pump (no dilution pump is fitted) and the sensor is a Honeywell Searchpoint Optima Plus infrared sensor.
Provide written attestation from the Administration [or RO acting on its behalf] that actual system is acceptable to the Administration, and updated ship-specific drawings depicting the actual system installed onboard.
74 SOLAS 14 VII/13.1 REF IGC 93/13.6.1
50ac
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.