PACIFIC YANTAI is a 2015 tank ship. The Coast Guard has recorded 12 inspections since 2018, most recently in April 2026, along with 2 deficiencies and 1 operational control.
Records from 2018 to 2026. Most recent: inspection, 18 April 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it48419 - Convention (Subpart B), Gross Ton 53999 - Dead Weight, Metric Ton 72807 - Displacement, Metric Ton 17391 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 January 2022Resolved
Lighting fittings should have pressurized enclosures or be of the flameproof type. PSCO observed one cracked light enclosure in the cargo compressor room and one in the cargo tank #4 area.
Action required: 10 - Deficiency Rectified
Resolved 3 January 2022
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 16 November 2018Resolved
Gas detection equipment acceptable to the Administration shall be provided.
Cargo Operations Manual, page 3-10 describes system as with catalytic sensor. Drawing no. 32630.GSS.02.01 pg 4 shows schematic of system with Consilium ST650EX HC/VCM gas detector. Drawing no. 32630.GSS.02.01 pg 2 says system has 2 pumps, 1 for analysis and 1 for dilution. This 2 pump arrangement is also shown on Drawing no. 32639.GSS.03.01 pg 2.
The actual system fitted onboard has only an analyzing pump (no dilution pump is fitted) and the sensor is a Honeywell Searchpoint Optima Plus infrared sensor.
Provide written attestation from the Administration [or RO acting on its behalf] that actual system is acceptable to the Administration, and updated ship-specific drawings depicting the actual system installed onboard.
74 SOLAS 14 VII/13.1 REF IGC 93/13.6.1
50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2018
Resolved 7 December 2018
Resolution: Received class report stating that onboard installation is acceptable to the RO. Also received updated drawings and change to Cargo Ops Manual to reflect onboard installation.