Records from 2018 to 2025. Most recent: inspection, 1 May 2025.
Documentation record
Registered dimensions (L × B × D)34.3 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 14 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · CAPE MAY COURT HOUSE, NJ, UNITED STATES · built 2019
Hull materialFRP (Fiberglass)
PropulsionDiesel Direct
Hull shapeShip
Hull configurationMonohull
Hailing portSINGER ISLAND, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
1 May 2025
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8127015
16 April 2025
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8112737
30 May 2024
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7922696
16 August 2023
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7769484
11 April 2023
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7666548
25 August 2022
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7543135
16 August 2021
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7288396
29 March 2021
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7164778
15 September 2020
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7058329
2 July 2020
DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7006969
5 June 2019
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6698508
11 October 2018
Plan Review "T" Boat · Drydock Exam · Internal Structural Exam · Construction Oversight · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6699290
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 May 2025
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: A means to reset devices used to automatically shut down engines. Engine override function is inoperable.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2025
Resolution: System repaired. Test conducted. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 May 2025
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station. Fwd alarm is currently inoperable.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 5 May 2025
Resolution: Tested.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 May 2025
Resolved
A vessel of more than 25 feet in length, but not more than 65 feet, must carry a minimum of one life buoy. Grab line on life buoy is unserviceable. Life buoy replaced. Corrected on the spot.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 1 May 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 May 2024
Resolved
The minimum number of fire extinguishers required on a vessel must be acceptable to the [name withheld] of two extinguishers on vessel was not fully charged.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2024
Resolution: New portable fire extinguisher provided while MI was on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 May 2024
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Indicators for both bilge pumps are inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 3 June 2024
Resolution: Replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 30 May 2024
Resolved
A vessel must carry either a first-aid kit or a kit with equivalent content. Content expired in kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 4 June 2024
Resolution: New kit procured.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 May 2024
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted. Placard is wasted/ripped.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 31 May 2024
Resolution: New donning placard installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 August 2023
Resolved
A vessel of more than 26' but not more than 65' must carry a minimum of one life buoy of not less than 24" in diameter. Grab line on life buoy unserviceable.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 August 2023
Resolved 16 August 2023
Resolution: Life buoy replaced. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 July 2020
Resolved
Replace expired water light battery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2020
Resolved 3 July 2020
Resolution: O/O replaced water light battery.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 July 2020
Resolved
Acquire alcohol test strips.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2020
Resolved 3 July 2020
Resolution: O/O purchased new testing strips.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 June 2019
Resolved
Mission updated 46CFR184.420 publications
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 June 2019
Resolution: Received photos of corrected def.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 June 2019
Resolved
Expired test strips.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 September 2019
Resolution: Vessel provided picture of new test strips.