Records from 2018 to 2024. Most recent: inspection, 22 May 2024.
Documentation record
Registered dimensions (L × B × D)31.0 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · CAPE MAY COURT HOUSE, NJ, UNITED STATES · built 2019
Hull materialFRP (Fiberglass)
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portATLANTIC CITY, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 9 December 2022 · expires 31 December 2023
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 12
22 May 2024
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7912710
10 January 2024
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7847684
14 September 2023
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7791369
1 March 2023
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7634234
24 May 2022
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7457895
24 May 2021
Annual Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7205616
11 February 2021
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7132419
8 June 2020
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6979388
22 November 2019
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6860719
12 June 2019
Type not recorded
No type recorded · Station Atlantic City · USCG East District (CGD-E) · Activity 6712489
22 May 2019
COI Inspection · Hull Examination · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6689680
11 October 2018
Administrative Inspection · Plan Review "T" Boat · Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6662870
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 January 2024
Resolved
The owner or managing operator shall make a vessel available for drydock examinations and internal structure examinations for certification.
Vessel has lapsed the drydock and internal structure exam expiration dates, 31MAY2023, on its COI.
Allow inspection for satisfactory drydock and internal structure exam credit prior to the carriage of passengers.
46 CFR 176.600
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 January 2024
Resolved 29 January 2024
Resolution: Vessel completed hull/ISE for credit dry dock.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 March 2023
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation.
Vessel's waterlight was not on board.
Vessel is limited to daylight operations until deficiency is rectified.
46 CFR 180.70(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 14 March 2023
Resolution: Vessel's waterlight was properly stowed onboard, deficiency cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 March 2023
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers.
Vessel has two different types of life jackets and current life jacket placard did not reflect proper donning procedures for vessel's current life jackets.
46 CFR 185.516(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 14 March 2023
Resolution: Vessel now displays (02) lifejackets placards, deficiency cleared.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 March 2023
Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 9.5 liter (2.5 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency.
All (03) of the vessel's fire buckets were capable of holding 2 gallons.
46 CFR 181.610
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 14 March 2023
Resolution: All (03) fire buckets have 2.5 gallon water capacity, deficiency cleared.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 March 2023
Resolved
The master of the vessel shall ensure that each EPIRB must be tested monthly using the integrated test circuit and output indicator, to determine that it is operative and shall be logged or otherwise documented.
Vessel master was unable to provide proof of monthly EPIRB testing.
46 CFR 185.728(a)+(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 14 March 2023
Resolution: Vessel master implemented monthly EPIRB testing log, deficiency cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 March 2023
Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color , and containers shall be clearly markers in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: "DISTRESS SIGNALS."
Vessel's portable watertight container for distress flares was improperly marked.
46 CFR 185.614
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 14 March 2023
Resolution: Vessel's distress signal container was properly marked, deficiency cleared.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 March 2023
Resolved
The minimum number of portable fire extinguishers required on a vessel much be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by Table 181.500(b).
Vessel's COI currently only requires (01) 40B:C and (01) 10B:C portable fire extinguishers. Vessel shall, at minimum, provide an additional 2A portable fire extinguisher to meet the requirements of the regulation.
46 CFR 181.500(a)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 14 March 2023
Resolution: Vessel added (01) 2-A portable fire extinguisher, deficiency cleared.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 May 2021
Resolved
REPLACE ENGINE ROOM BILGE FLOAT. 46 CFR 182.520(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 June 2021
Resolution: O/O provided video of bilge alarm operating properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 May 2019
Resolved
Water lights on lifering have wrong battery installed. Battery has spring type electrical contacts and is not listed as an approved battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 22 May 2019