HORTEN

HORTEN is a tank ship. The Coast Guard has recorded 7 inspections since 2019, most recently in May 2026, along with 1 deficiency.

Records from 2019 to 2026. Most recent: inspection, 1 May 2026.

Built
Not recorded
Last inspected
1 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 May 2026
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2019–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9740342
1537170
Flag
LIBERIA
Maury page id
psix-1537170

Documentation record

Tonnage as PSIX records it157316 - Convention (Subpart B), Gross Ton
297639 - Dead Weight, Metric Ton
107819 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 7

1 May 2026 PSC B · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8349460
16 August 2025 COE-Administrative
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8211079
24 December 2024 COC-TVE Annual
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8046623
9 November 2023 COC-TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7822568
1 December 2020 In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7104599
22 September 2019 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6815220
19 September 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6815782

Deficiency record · 1

07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 24 December 2024 Resolved
The protection of the cargo tanks shall be achieved by a fixed inert gas system in accordance with the requirements of the Fire Safety Systems Code. The inert gas system shall be capable of delivering inert gas to the cargo tanks at a rate of at least 125% of the max rate of discharge. PSCO was unable to witness satisfactory operation of the #1 IG blower. #2 IG blower is operational as well as topping off IGG. PSCO witnessed the "low/low deck pressure" trip of the cargo pumps & local/remoted ESD trips of all 03 COPs. Captain has provided risk mitigation for the inoperable IG blower & flag surveyor has required the deficiency to be resolved prior to cargo discharge.
Action required: 10 - Deficiency Rectified
Resolved 24 December 2024

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.