Records from 1986 to 2008. Most recent: inspection, 11 July 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
11 July 2008
Type not recorded
No type recorded · Station Monterey · USCG Southwest District (CGD-SW) · Activity 3264895
29 January 2002
Type not recorded
No type recorded · USCGC BLACKFIN (WPB 87317) · USCG Southwest District (CGD-SW) · Activity 1524307
6 September 1994
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 863753
5 August 1994
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 862008
5 July 1994
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1173292
8 June 1993
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 844273
24 May 1993
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 838256
23 July 1992
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 936640
4 January 1990
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1236260
3 July 1989
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1281223
6 June 1989
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1201011
31 May 1989
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1348978
2 December 1988
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 896285
17 June 1988
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1205559
23 December 1987
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1006268
6 July 1987
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1320259
2 July 1987
Re-Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1320256
13 June 1986
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 984735
Lifesaving
Issued 5 July 1994
Resolved
CONDUCT SAT U/W MAN OVERBOARD TEST WITH SENIOR DECKHAND PRESENT.
Condition: Unknown
Due 19 July 1994
Resolved 26 September 1994
Lifesaving
Issued 5 July 1994
Resolved
RE-STENCIL NAME ON B/A AND REPLACE WATERLIGHT BATTERIES. OPERATION OF VSL RESTRICTED TO DAYTIME IN CLEAR VISIBILITY CONDITIONS UNTIL THIS ITEM COMPLETED.
Condition: Unknown
Due 19 July 1994
Resolved 26 September 1994
Engineering
Issued 5 July 1994
Resolved
STENCIL "EMERGENCY FUEL CUTOFF VALVE" IN ADDITION TO AN INDICATING ARROW ONBULKHEAD BY FORWARD SHUTOFF VALVE. STENCIL INDICATING ARROW BY AFT FUEL SHUTOFF VALVE.
Condition: Unknown
Due 19 July 1994
Resolved 26 September 1994
Engineering
Issued 5 July 1994
Resolved
PROVIDE 30X30 MESH SCREEN FOR FUEL TANK VENT. THIS ITEM MUST BE COMPLETED PRIOR TO SAILING.
Condition: Unknown
Due 19 July 1994
Resolved 26 September 1994
Documentation
Issued 5 July 1994
Resolved
RENEW CERTIFICATE OF DOCUMENTATION (DUE 31JUL94).
Condition: Unknown
Due 19 July 1994
Resolved 26 September 1994
Construction/Loadline
Issued 5 July 1994
Resolved
REMOVE BILGE OIL.
Condition: Unknown
Due 19 July 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 5 July 1994
Resolved
PROVIDE CAP FOR E/R HATCH TO ENSURE WEATHERTIGHTNESS. THIS ITEM TO BE COMPLETED PRIOR TO SAILING.
Condition: Unknown
Due 19 July 1994
Resolved 26 September 1994
Fire Fighting
Issued 5 July 1994
Resolved
SERVICE ALL FIRE EXTINGUISHERS. THIS ITEM TO BE COMPLETED PRIOR TO SAILING.
Condition: Unknown
Due 19 July 1994
Resolved 26 September 1994
Documentation
Issued 5 July 1994
Resolved
PROVIDE THE FOLLOWING FOR THE DRUG TESTING PROGRAM: (A) ADDRESS HOW RANDOM TESTING IS CONDUCTED (B) INCLUDE INFORMATION ON PERIODIC TESTING (C) ENSURETESTING LABORATORY IS NIDA APPROVED.
Condition: Unknown
Due 19 July 1994
Resolved 26 September 1994
Construction/Loadline
Issued 5 July 1994
Resolved
EFFECT PROPER REPAIR OF DAMAGE TO STARBOARD AFT QUARTER HULL (VERTICAL SLITABOVE FREEING PORT; DAMAGE CAUSED BY OTHER VSL HITTING SCUBA-DO LATE EVE- EARLY MORNING). REPAIR DELAMINATION OF BULWARKS ON TOP.
Condition: Unknown
Due 5 August 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 3 July 1989
Resolved
MAKE NEW HATCH AFT OF ENGINE SPACE WATERTIGHT.
Condition: Unknown
Due 3 July 1989
Resolved 3 July 1989
Engineering
Issued 6 June 1989
Resolved
DRILL AND PEN OR DOUBLE NUT TRANSMISSION LINKAGE.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Lifesaving
Issued 6 June 1989
Resolved
INSTALL VERTICAL BRACKETS ON LAUNCHING APPARATUS FOR BUOYANT APPARATUS.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Navigation
Issued 6 June 1989
Resolved
PROVIDE COMPASS DEVIATION TABLE FOR MAGNETIC COMPASS.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Engineering
Issued 6 June 1989
Resolved
REMOVE OR RE-PLUMB TWO UNUSED FUEL TANKS SEPARATE FROM FUEL SYSTEM OR INSTALL REMOTE FUEL SHUT-OFF VALVES AS REQUIRED FOR FUEL SYSTEMS.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Engineering
Issued 6 June 1989
Resolved
INSTALL VALVE ON FUEL TANK ACCESSIBLE FROM OUTSIDE FUEL TANK COMPARTMENT (EMERGENCY FUEL SHUT-OFF).
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Accommodation/Occupational Safety
Issued 6 June 1989
Resolved
REPLACE PORT-A-POTTIE WITH USCG APPROVED MSD.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Accommodation/Occupational Safety
Issued 17 June 1988
Resolved
LABEL FORWARD LIFE JACKET LOCKER AND EXTERIOR OF FORWARD ESCAPE HATCH.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Documentation
Issued 17 June 1988
Resolved
POST STABILITY LETTER UNDER GLASS OR OTHER SUITABLE TRANSPARENT MATERIAL.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Engineering
Issued 17 June 1988
Resolved
DOUBLE-NUT ENGINE THROTTLE CABLE.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Engineering
Issued 17 June 1988
Resolved
MOUSE FUEL OIL SHUT-OFF CABLE SHACKLES.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Documentation
Issued 17 June 1988
Resolved
PROVIDE FCC SAFETY RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Lifesaving
Issued 17 June 1988
Resolved
PROVIDE NEW PENDANTS FOR BOUYANT APPARATUS, WHICH ARE RESISTANT TO ULTRA- VIOLET RAYS, PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Lifesaving
Issued 17 June 1988
Resolved
RENEW BOUYANT APPARATUS PAINTER.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988