Records from 2018 to 2026. Most recent: inspection, 12 January 2026.
Inspection history · 16
12 January 2026
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8291533
29 May 2025
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8145220
1 October 2024
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8011792
5 June 2024
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7938409
11 March 2024
COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7875981
28 June 2023
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7724592
20 October 2022
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7580387
18 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7579589
3 August 2022
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7522195
27 September 2021
In-Service Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7319540
1 July 2021
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7239585
29 October 2020
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7084820
2 July 2020
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6992323
1 March 2019
Simplified Stability Test
Physical examination · Marine Safety Center (MSC) · Activity 6634755
1 February 2019
COI Inspection · Plan Review "T" Boat · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6633105
1 October 2018
Construction Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6562997
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 October 2024
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alternations are made. Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement, repair, or refastening of deck or hull planking, plating, and structural members; repair of plate or frame cracks; damage repair or replacement, other than replacement in kind, of electrical wiring, fuel lines, tanks, boilers and other pressure vessels, and steering, propulsion and power supply systems; alterations affecting stability; and repair or alteration of lifesaving, fire detecting, or fire extinguishing equipment.
The electrical system on board the vessel is not IAW the approved electrical plan P022049, dated 04/17/2019. Unapproved extension cords, connections, lights, power inverter, and additional battery was identified. Configure the electrical system IAW the approved electrical plan P022049, dated 04/17/2019.
46CFR176.700(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2024
Resolution: Unapproved extension cords, connections, lights, power inverter, and additional battery was removed from the vessel. The electrical system on board the vessel is now IAW the approved electrical plan P022049, dated 04/17/2019.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 October 2024
Resolved
A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter. The grab lines on the ring life buoy are excessively deteriorated. Replace ring life buoy.
46CFR180.70(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2024
Resolution: Replaced ring life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 October 2024
Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110.(2) Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy.(3) Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 22.7 kilograms (50 pounds), and allow the waterlight to be quickly disconnected from the ring life buoy. Water light is non-operable, repair or replace waterlight, with non-expired battery.
46CFR180.70(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2024
Resolution: Water light is now operable, replaced battery in waterlight.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 August 2022
Resolved
Vessel was overdue for annual inspection due to inspector availability.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 August 2022
Resolved 3 August 2022
Resolution: Cleared on the spot. Educated owner to schedule well in advance of due date to avoid any future restrictions in operations.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 July 2021
Resolved
Provide light for ring buoy and new buoyant life line.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 13 July 2021
Resolution: Received photo of new light for ring buoy.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 July 2021
Resolved
Provide first aid kit that meets 46CFR160.041.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 13 July 2021
Resolution: Received photo of new first aid kit.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 1 July 2021
Resolved
Provide current Coast Pilot, chart, tide tables and light list for navigation area.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 13 July 2021
Resolution: Received photo of new publications.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 July 2021
Resolved
Post life jacket donning instructions.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 13 July 2021
Resolution: Received photo of life jacket donning instructions.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 July 2020
Resolved
All 03 fire extinguishers need proof of annual testing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2020
Resolved 12 August 2020
Resolution: Received photos via e-mail of 03 new fire extinguishers placed in service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 July 2020
Resolved
Replace grab line on ring life buoy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2020
Resolved 12 August 2020
Resolution: Received photos of new grab line on ring buoy.