MAURY USCG vessel records
← All vessels

NEW ASSURANCE

NEW ASSURANCE is a tank ship. The Coast Guard has recorded 4 inspections since 2018, most recently in August 2024, along with 1 deficiency.

Records from 2018 to 2024. Most recent: inspection, 14 August 2024.

Built
Not recorded
Last inspected
14 August 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 August 2024
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2018–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9799161
1537461
Flag
HONG KONG
Maury page id
psix-1537461

Documentation record

Tonnage as PSIX records it163186 - Convention (Subpart B), Gross Ton
101960 - Convention (Subpart B), Net Ton
307524 - Dead Weight, Ton
352003 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

14 August 2024 COC-TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7981001
27 March 2023 PSC B · Administrative Inspection · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7652871
18 March 2020 PSC B · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6899581
29 December 2018 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6589245

Deficiency record · 1

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 March 2023 Resolved
IN TANKERS, ELECTRICAL EQUIPMENT, CABLES AND WIRING SHALL NOT BE INSTALLED IN HAZARDOUS LOCATIONS UNLESS IT CONFORMS WITH STANDARDS NOT INFERIOR TO THOSE ACCETABLE TO THE ORGANIZATION. PSCO OBSERVED 02 EXPLOSION PROOF LIGHT ON DECK INSIDE SOPEP LOCKER WITH CRACKED LENSES.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 27 March 2023
Resolved 27 March 2023
Resolution: REPLACEMENT OF EXPLOSION PROOF LIGHT MADE ON THE SPOT.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.