Records from 2019 to 2026. Most recent: inspection, 23 February 2026.
Inspection history · 5
23 February 2026
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8312859
4 March 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7874021
8 January 2024
PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7844100
1 February 2021
PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7129696
14 February 2019
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6620825
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 8 January 2024
Resolved
09227 - Ropes and Wires - Ships shall be provided with arrangement, equipment and fittings of sufficent safe working load to enable the safe conduct of all towing and mooring operations associated with normal operation of the ship. Mooring lines found to be excessively frayed on two forward line assemblies. Mooring lines should be replaced with unfrayed lines. 74 SOLAS II-1 / 3-8.2 - 50ac.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2024
Resolved 30 January 2024
Resolution: VSL provided a Flag State report attesting to the new mooring lines being placed along the capstans upon departure from the Sector Columbia River COTP Zone. See documents for further details.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 1 February 2021
Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE, THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. VESSEL HAS OIL LEAKS ON NUMBER 1 AND 3 FUEL INJECTORS AND NUMBER 2 FUEL FILTER.
74 SOLAS (14) II-2/4.1.1
17(a)(c)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2021
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 1 February 2021
Resolved
FIRE PROTECTION SYSTEMS AND FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE MAINTAINED READY FOR USE. FIRE MAIN SYSTEM WAS ISOLATED TO THE SUPERSTRUCTURE AND DID NOT REACH THE BOW.
74 SOLAS (14) II-2/14.1.1
10(C)
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 1 February 2021
Resolution: VESSEL OPENED THE ISOLATION VALVE AND WAS ABLE TO GET PRESSURE TO THE FORWARD FIRE STATION.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 February 2021
Resolved
FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. GENERAL SERVICE FIRE PUMPS ONE AND TWO WERE EXPERIENCING OVERFLOW AND LEAKING ISSUES DUE TO A CLOGGED DRAIN HOSE.
74 SOLAS (14) II-2/14.2.1.2
17(A)(C)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2021
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 February 2021
Resolved
MEANS SHALL BE PROVIDED TO LIMIT THE ACCUMULATION OF FLAMMABLE VAPOURS. INAPPROPRIATE STORAGE OF PAINT BUCKETS AND OIL SOAKED/FILLED BUCKETS BEHIND FLAMMABLE LIQUID HOLDING TANK.
74 SOLAS (14) II-2/4.1.2
10(C)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 February 2021
Resolution: VESSEL MOVED THE BUCKETS IN QUESTION TO A MORE SUITABLE AREA ON THE VESSEL IN AN EFFORT TO ENSURE CLEANLINESS AND PREVENT RISK OF FIRE.