GRANDE COTONOU

GRANDE COTONOU is a 2014 freight ship. The Coast Guard has recorded 13 inspections since 2018, most recently in July 2026, along with 5 deficiencies and 1 operational control.

Records from 2018 to 2026. Most recent: inspection, 31 July 2026.

Built
2014
Last inspected
31 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 31 July 2026
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2018–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9672105
1537755
Flag
ITALY
Maury page id
psix-1537755

Documentation record

Tonnage as PSIX records it71543 - Regulatory (Subpart C or D), Gross Ton
21462 - Regulatory (Subpart C or D), Net Ton
71543 - Convention (Subpart B), Gross Ton
32000 - Dead Weight, Ton
53900 - Displacement, Ton
21462 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

31 July 2026 COE-Administrative
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8451568
8 May 2025 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8130900
6 May 2025 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8129601
16 October 2024 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8019621
3 April 2024 PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7884545
2 April 2024 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7889026
4 December 2023 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7833378
28 September 2022 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7567254
8 February 2019 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6623652
27 December 2018 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6603144
15 November 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6581142
11 November 2018 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6578822
11 November 2018 COE-Offshore
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6579958

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 16 October 2024 Resolved
Plans and booklets shall be kept up to date, any alterations thereto shall be recorded as soon as practicable. PSCO observed a self closing fire door not located in the correct location IAW ships FCP in the incinerator space.
Action required: 10 - Deficiency Rectified
Resolved 16 October 2024
Resolution: Vessel crew amended all fire controls plans to reflect self closing fire door location. Class survey approved and signed each one. All sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 October 2024 Resolved
The construction of doors and door frames in "A" class divisions with the means of securing them when closed. PSCO observed a self closing door leaving the incinerator space not latching closed.
Action required: 10 - Deficiency Rectified
Resolved 16 October 2024
Resolution: Vessel crew repaied door latch. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 October 2024 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs. Fire detections and fire alarms. PSCO observed a fault on the fire detection panel on the bridge Zone 8 smoke detector 31 no answer.
Action required: 10 - Deficiency Rectified
Resolved 16 October 2024
Resolution: Vessel crew replaced detector sensor. All sat.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 28 September 2022 Resolved
Oil fuel pipes shall be fitted with a valve on the tank capable of being closed. PSCO discovered wooden blocks placed on 02 quick closing valves on the MGO tank, located in the purifier room, that prevented the valves from quick activation and use. 74SOLAS(20) II-2/4.2.2.3.4
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2022
Resolution: Cleared on the spot to the satisfaction of the PSCO
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 28 September 2022 Resolved
Where the contents and use of a space are such that there is doubt as to its classification for the purpose of this regulation, it shall be treated as a space within the relevant category having the most stringent boundary requirements. The Refrigerant Room (Cat 7) is being utilized as an office/workshop (Cat 3) for the electrician. 74SOLAS(20)II-2/9.2.3.3.2.2
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 November 2023
Resolution: Received attestation from Class that the makeshift, electrician workshop was removed from the AC room and that the AC room is solely being used for its original intended purpose.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.