GRANDE COTONOU
GRANDE COTONOU is a 2014 freight ship. The Coast Guard has recorded 13 inspections since 2018, most recently in July 2026, along with 5 deficiencies and 1 operational control.
Records from 2018 to 2026. Most recent: inspection, 31 July 2026.
- Built
- 2014
- Last inspected
- 31 July 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9672105 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
IBDT
1537755
Flag
ITALY
—
Maury page id
psix-1537755
Inspections, by type
…with no type recorded5
Years with a record
7 calendar years (2018–2026)
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it71543 - Regulatory (Subpart C or D), Gross Ton
21462 - Regulatory (Subpart C or D), Net Ton
71543 - Convention (Subpart B), Gross Ton
32000 - Dead Weight, Ton
53900 - Displacement, Ton
21462 - Convention (Subpart B), Net Ton
21462 - Regulatory (Subpart C or D), Net Ton
71543 - Convention (Subpart B), Gross Ton
32000 - Dead Weight, Ton
53900 - Displacement, Ton
21462 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 13
31 July 2026
COE-Administrative
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8451568
8 May 2025
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8130900
6 May 2025
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8129601
16 October 2024
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8019621
3 April 2024
PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7884545
2 April 2024
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7889026
4 December 2023
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7833378
28 September 2022
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7567254
8 February 2019
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6623652
27 December 2018
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6603144
15 November 2018
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6581142
11 November 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6578822
11 November 2018
COE-Offshore
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6579958
Deficiency record · 5
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 16 October 2024
Resolved
Plans and booklets shall be kept up to date, any alterations thereto shall be recorded as soon as practicable. PSCO observed a self closing fire door not located in the correct location IAW ships FCP in the incinerator space.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 October 2024
Resolved
The construction of doors and door frames in "A" class divisions with the means of securing them when closed. PSCO observed a self closing door leaving the incinerator space not latching closed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 October 2024
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs. Fire detections and fire alarms. PSCO observed a fault on the fire detection panel on the bridge Zone 8 smoke detector 31 no answer.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 28 September 2022
Resolved
Oil fuel pipes shall be fitted with a valve on the tank capable of being closed. PSCO discovered wooden blocks placed on 02 quick closing valves on the MGO tank, located in the purifier room, that prevented the valves from quick activation and use.
74SOLAS(20) II-2/4.2.2.3.4
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 28 September 2022
Resolved
Where the contents and use of a space are such that there is doubt as to its classification for the purpose of this regulation, it shall be treated as a space within the relevant category having the most stringent boundary requirements. The Refrigerant Room (Cat 7) is being utilized as an office/workshop (Cat 3) for the electrician.
74SOLAS(20)II-2/9.2.3.3.2.2
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.