Records from 2019 to 2026. Most recent: inspection, 15 April 2026.
Documentation record
Registered dimensions (L × B × D)40.0 ft × 16.0 ft × 4.3 ft
Registered tonnagegross 9 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGOLD COAST YACHTS INC · ST CROIX, VI, UNITED STATES · built 2018
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portFAJARDO, PR
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 April 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3 - Dead Weight, Ton
7 - Displacement, Ton
9 - Simplified, Gross Ton
9 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 21
15 April 2026
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8349872
30 September 2025
Hull Examination · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8243260
27 February 2025
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8085048
24 February 2025
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8083931
20 May 2024
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7915489
22 March 2024
COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7878202
22 September 2023
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7797959
1 February 2023
DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7629188
1 September 2022
Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7548875
6 June 2022
DAPI Audit · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7473804
11 May 2022
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7448333
1 July 2021
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7240293
19 April 2021
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7226013
9 November 2020
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7092511
16 July 2020
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7001334
15 April 2020
Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6939487
6 August 2019
Administrative Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6775082
7 June 2019
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 6706800
4 June 2019
COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6701876
16 May 2019
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6685610
15 February 2019
Construction Oversight · Administrative Inspection · Initial Certification · Deadweight Survey
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6626550
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2025
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 The following restrictions apply:(1) Flexible nonmetallic hose must be complete with factory-assembled end fittings requiring no further adjustment of the fittings on the hose, or field attachable type fittings may be used. Hose end fittings must comply with SAE J-1475. In systems and applications where flexible hoses are permitted to be clamped:(1) Double hose clamping is required where practicable;(2) The clamps must be of a corrosion resistant metallic material;(3) The clamps must not depend on spring tension for their holding power; and(4) Two clamps must be used on each end of the
hose, or one hose clamp can be used if the pipe ends are expanded or beaded to provide a positive stop against hose slippage. *In both port and starboard, all fuel flexible gasoline hoses after the fuel tank were found to be Synflex brand, marking 34M1-05, which does not meet the requirement for having fire sleeve protection, and not to be double clamped to prevent hose slippage from its fitting. 46 CFR 182.720(e) and 46 CFR 182.410
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2025
Resolved 27 March 2025
Resolution: Approved hoses under ABYC standard were installed, and double clamped.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 March 2024
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Bilge high-level visual and audible alarm is not operational.
46 CFR 182.530(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 March 2024
Resolution: Alarms operational demonstrated via digital evidence.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 22 March 2024
Resolved
Fuel lines must be accessible, protected from mechanical injury, and effectively secured against excessive movement and vibration by the use of soft nonferrous metal straps which have no sharp edges and are insulated to protect against corrosion. Port fuel line was chaffed due to vibration, replace and insulate.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 March 2024
Resolution: Hose replaced.