MAURY USCG vessel records Sign in
← All vessels

WOLFFISH

WOLFFISH is a 1977 offshore supply vessel. The Coast Guard has recorded 35 inspections since 1989, most recently in February 2012, along with 15 deficiencies.

Records from 1989 to 2012. Most recent: inspection, 1 February 2012.

Built
1977
Last inspected
1 February 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8758536 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDC6579
153929
Flag
UNITED STATES
366817960, 367058110 (licence lapsed)
Maury page id
psix-153929

Inspections, by type

…with no type recorded1
Years with a record 18 calendar years (1989–2012)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it67 - Regulatory (Subpart C or D), Net Ton
99 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC6579MMSI 367058110 · expired · compulsorily equipped · granted 22 July 2005, cancelled 26 September 2015
WDA5238MMSI 366817960 · cancelled · compulsorily equipped · granted 6 July 2001, cancelled 31 July 2006 · licensed under a name not among this hull’s recorded names (not shown)
WCP4376MMSI not assigned · expired · compulsorily equipped · granted 17 February 1999, cancelled 19 February 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 35

1 February 2012 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4235876
18 September 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3327580
13 April 2007 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2907274
22 January 2007 Re-Inspection · Hull Examination · Ballast Water Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2859692
1 June 2006 Ballast Water Examination · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2667079
23 November 2005 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2539964
10 May 2005 Re-Inspection · Ballast Water Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2359980
16 January 2004 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1986593
3 July 2003 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1834008
25 April 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1780356
9 September 2002 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1674199
4 January 2002 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473788
17 January 2001 Examination of Repairs · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1455947
29 December 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458707
17 August 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 777260
28 May 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 801984
12 March 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 807090
12 February 1999 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395100
18 December 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439951
18 February 1997 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1363942
11 February 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1185593
11 January 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1374493
20 October 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1193553
10 March 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1377355
14 January 1994 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1356491
9 April 1993 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 840895
21 January 1993 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370539
15 November 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 935196
20 December 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1221658
18 December 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 901301
13 December 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 930260
22 October 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 903122
15 August 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 927764
24 October 1989 Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1226649
7 March 1989 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1043277

Deficiency record · 15

Operations/Management › Drills/Instruction › Not Conducted
Issued 1 June 2006 Resolved
Run and log all required boat drills.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 June 2006
Resolution: All drills ran and logged properly.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 1 June 2006 Resolved
Provide third party inspection of all system components, to identify systems as "fail safe" or not, and any components not rated for maximum system operating pressure. Repair/replace all identified components. Provide approved (MSC) plans of vessel hydraulic system prior to next annual inspection.
Action required: 705 - Other - as specified
Due 1 September 2007
Resolved 13 April 2007
Electrical › Electric Supply System (service)
Issued 17 January 2002 Resolved
No drip cover on battery charger. LEGACY COMPONENT DESC: Battery Charger
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2002
Resolution: Installed cover.
Navigation › Piloting/Steering
Issued 17 January 2002 Resolved
Light List not updated version. LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2002
Resolution: Placed new edition aboard.
Communications › Audible Communications
Issued 17 January 2002 Resolved
Ships whistle inop. LEGACY COMPONENT DESC: Horn/Whistle
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2002
Resolution: Root valve from air receiver closed; opened same.
Construction/Loadline › Hull
Issued 4 January 2002 Resolved
Hull plating beyond allowable wastage. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2002
Resolution: Renewed plating and associated internals as per accompaning case narrative.
Lifesaving
Issued 12 February 1999 Resolved
DEMONSTRATE COMPLIANCE WITH THE 8TH COAST GUARD DISTRICT'S POLICY "RESCUE BOAT REQUIREMENTS ON OFFSHORE SUPPLY VESSELS" DATED 12NOV98 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 12 February 1999
Resolved 12 February 1999
Documentation
Issued 15 November 1991 Resolved
PROVIDE ON BOARD A COAST GUARD APPROVED OPERATIONS MANUAL
Condition: Unknown
Due 15 November 1991
Resolved 15 November 1991
Electrical
Issued 13 December 1990 Resolved
PROVE PROPER OPERATION OF PORT GENERATOR OVERSPEED.
Condition: Unknown
Due 13 December 1990
Resolved 13 December 1990
Documentation
Issued 13 December 1990 Resolved
PROVIDE ON BOARD CURRENT CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 13 December 1990
Resolved 13 December 1990
Documentation
Issued 24 October 1989 Resolved
PROVIDE ON BOARD VESSEL A COAST GUARD ISSUED STABILITY LETTER.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Lifesaving
Issued 24 October 1989 Resolved
INSTALL A SUITABLE MEANS OF ESCAPE.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Deck/Cargo
Issued 24 October 1989 Resolved
PROVIDE LOAD TEST OF CRANE. IF NOT WITNESSED BY ABS OR ICGB, THE TEST MUSTBE PERFORMED IN THE PRESENCE OF A COAST GUARD INSPECTOR IN ACCORDANCE WITH 46 CFR 107.258 AND 46 CFR 107.260.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Accommodation/Occupational Safety
Issued 24 October 1989 Resolved
PROVIDE CLOTHING STORAGE LOCKERS FOR EACH CREW BUNK.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Documentation
Issued 24 October 1989 Resolved
SUBMIT PLANS SHOWING GENERAL ARRANGEMENT, INBOARD/OUTBOARD PROFILE, FIRE CONTROL PLAN (>100GT) AND A STRUCTURAL ANALYSIS OF ALL LEGS AND LEG TOWER SUPPORTS TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.