Records from 1989 to 2012. Most recent: inspection, 1 February 2012.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 35
1 February 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4235876
18 September 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3327580
13 April 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2907274
22 January 2007
Re-Inspection · Hull Examination · Ballast Water Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2859692
1 June 2006
Ballast Water Examination · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2667079
23 November 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2539964
10 May 2005
Re-Inspection · Ballast Water Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2359980
16 January 2004
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1986593
3 July 2003
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1834008
25 April 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1780356
9 September 2002
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1674199
4 January 2002
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473788
17 January 2001
Examination of Repairs · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1455947
29 December 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458707
17 August 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 777260
28 May 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 801984
12 March 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 807090
12 February 1999
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395100
18 December 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439951
18 February 1997
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1363942
11 February 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1185593
11 January 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1374493
20 October 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1193553
10 March 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1377355
14 January 1994
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1356491
9 April 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 840895
21 January 1993
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370539
15 November 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 935196
20 December 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1221658
18 December 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 901301
13 December 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 930260
22 October 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 903122
15 August 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 927764
24 October 1989
Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1226649
7 March 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1043277
Operations/Management › Drills/Instruction › Not Conducted
Issued 1 June 2006
Resolved
Run and log all required boat drills.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 June 2006
Resolution: All drills ran and logged properly.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 1 June 2006
Resolved
Provide third party inspection of all system components, to identify systems as "fail safe" or not, and any components not rated for maximum system operating pressure. Repair/replace all identified components. Provide approved (MSC) plans of vessel hydraulic system prior to next annual inspection.
Action required: 705 - Other - as specified
Due 1 September 2007
Resolved 13 April 2007
Electrical › Electric Supply System (service)
Issued 17 January 2002
Resolved
No drip cover on battery charger. LEGACY COMPONENT DESC: Battery Charger
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2002
Resolution: Installed cover.
Navigation › Piloting/Steering
Issued 17 January 2002
Resolved
Light List not updated version. LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2002
Resolution: Placed new edition aboard.
Communications › Audible Communications
Issued 17 January 2002
Resolved
Ships whistle inop. LEGACY COMPONENT DESC: Horn/Whistle
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2002
Resolution: Root valve from air receiver closed; opened same.
Construction/Loadline › Hull
Issued 4 January 2002
Resolved
Hull plating beyond allowable wastage. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2002
Resolution: Renewed plating and associated internals as per accompaning case narrative.
Lifesaving
Issued 12 February 1999
Resolved
DEMONSTRATE COMPLIANCE WITH THE 8TH COAST GUARD DISTRICT'S POLICY "RESCUE BOAT REQUIREMENTS ON OFFSHORE SUPPLY VESSELS" DATED 12NOV98 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 12 February 1999
Resolved 12 February 1999
Documentation
Issued 15 November 1991
Resolved
PROVIDE ON BOARD A COAST GUARD APPROVED OPERATIONS MANUAL
Condition: Unknown
Due 15 November 1991
Resolved 15 November 1991
Electrical
Issued 13 December 1990
Resolved
PROVE PROPER OPERATION OF PORT GENERATOR OVERSPEED.
Condition: Unknown
Due 13 December 1990
Resolved 13 December 1990
Documentation
Issued 13 December 1990
Resolved
PROVIDE ON BOARD CURRENT CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 13 December 1990
Resolved 13 December 1990
Documentation
Issued 24 October 1989
Resolved
PROVIDE ON BOARD VESSEL A COAST GUARD ISSUED STABILITY LETTER.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Lifesaving
Issued 24 October 1989
Resolved
INSTALL A SUITABLE MEANS OF ESCAPE.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Deck/Cargo
Issued 24 October 1989
Resolved
PROVIDE LOAD TEST OF CRANE. IF NOT WITNESSED BY ABS OR ICGB, THE TEST MUSTBE PERFORMED IN THE PRESENCE OF A COAST GUARD INSPECTOR IN ACCORDANCE WITH 46 CFR 107.258 AND 46 CFR 107.260.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Accommodation/Occupational Safety
Issued 24 October 1989
Resolved
PROVIDE CLOTHING STORAGE LOCKERS FOR EACH CREW BUNK.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Documentation
Issued 24 October 1989
Resolved
SUBMIT PLANS SHOWING GENERAL ARRANGEMENT, INBOARD/OUTBOARD PROFILE, FIRE CONTROL PLAN (>100GT) AND A STRUCTURAL ANALYSIS OF ALL LEGS AND LEG TOWER SUPPORTS TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989