MAURY USCG vessel records Sign in
← All vessels

FENG SHOU HAI

FENG SHOU HAI is a 2017 freight ship. The Coast Guard has recorded 6 inspections since 2018, most recently in January 2025, along with 2 deficiencies and 1 operational control.

Records from 2018 to 2025. Most recent: inspection, 21 January 2025.

Built
2017
Last inspected
21 January 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9727651 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1539557
Flag
HONG KONG
—
Maury page id
psix-1539557

Inspections, by type

…with no type recorded1
Years with a record 4 calendar years (2018–2025)
The 6 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it36378 - Convention (Subpart B), Gross Ton
21646 - Convention (Subpart B), Net Ton
75197 - Displacement, Metric Ton
63365 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 6

21 January 2025 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8066698
28 March 2022 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7420058
16 March 2022 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7404986
23 June 2020 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6974709
7 December 2018 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6593705
28 November 2018 ISPS II Exam · Administrative Inspection · PII Safety Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6588256

Deficiency record · 2

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 March 2022 Resolved
No person may use any equipment listed in paragraph (c) of this section for transfer operations unless the vessel or facility operator, as appropriate, tests and inspects the equipment in accordance with paragraphs (b), (c), and (f) of this section and the equipment is in the condition specified in paragraph (c) of this section. For the purpose of paragraph (a) of this section: Each loading arm and each transfer pipe system must not leak under static liquid pressure at least 1 1/2 times the maximum allowable working pressure. PSCO observed the transfer pipe system was pressure tested pneumatically and not by means of static liquid pressure.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 28 March 2022
Resolution: Conducted hydrostatic test of transfer pipes, submitted photos of test.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 16 March 2022 Resolved
Oil filtering equipment referred to in paragraph 2 of this regulation shall comply with paragraph 6 of this section. In addition, considering the design of such equipment and approvals, the administration shall have regard to the specification recommended by the specification recommended by the organization.* Per MEPC 107(49) performance and test specification for pollution prevention equipment. Oil content meter calibration certification shall not exceed 5 years. Vessel could not provide valid oil content meter calibration certificate. Correct cite MARPOL Annex I reg. 14/7. 16 a,c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2022
Resolution: New OCM installed with new OCM calibration certificate. Submitted class report attesting to instalation of OCM.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.