Records from 2018 to 2023. Most recent: inspection, 15 August 2023.
Inspection history · 5
15 August 2023
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7770149
1 August 2023
Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7758286
15 July 2023
COC-CVE Initial · PSC A
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7725182
10 April 2020
In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6937871
1 November 2018
COC-CVE Initial · COC-CVE Initial Prep
Administrative · Activities Europe · Activity 6585390
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 August 2023
Resolved
Failure to provide notice of arrival at least 24 hours before entering the port or place of destination when embarking on a voyage of less than 96 hours.
Action required: 10 - Deficiency Rectified
Due 15 August 2023
Resolved 15 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 15 July 2023
Resolved
In addition to complying with the specific provisions for fire integrity of bulkheads and decks of passenger ships, the minimum fire integrity of all bulkheads and decks shall be as prescribed in tables 9.1 and 9.2. Electrical Room on Deck 6, aft, leading to the Nature Walk is a category 10 space. The space was filled with numerous new televisions and other equipment in boxes. 74 SOLAS 20 II-2/9.2.2.3.1 (16a) 07101
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2023
Resolved 15 July 2023
Resolution: DNV surveyor in attendance verified item completion.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 July 2023
Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, openings shall be provided with permanently attached means of closing wich shall be at least as effective for resisting fires as the divisions in which they are fitted. The hinges on a B-15 door, deck 6, leading to the Nature Walk was damaged during the vessels' last fire drill by way of wooden wedges. The door was found misaligned and opened with the bottom half of the door making contact with the bulkhead framing. 74 SOLAS 20 II-2/9.4.1.1.1 (16a) 07105
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2023
Resolved 15 July 2023
Resolution: DNV surveyor in attendance verified item completion.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 July 2023
Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. A B-15 door framing on Engine Room Duct Fan, 576.3342 Airlock was found detached from the door framing. 74 SOLAS 20 II-/9.4.1.1.1 (16a) 07105
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2023
Resolved 15 July 2023
Resolution: DNV surveyor in attendance verified item completion.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 July 2023
Resolved
Electrical installations shall be such that electrical services for safety will be ensured under various emergency conditions. The cover for a junction box on the supply fan, engine room B D1 574.4120.10 was found missing. 74 SOLAS 20 II-1/40.1.2 (10c) 09209
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 July 2023