HANSEATIC INSPIRATION

HANSEATIC INSPIRATION is a 2019 passenger vessel (inspected). The Coast Guard has recorded 12 inspections since 2019, most recently in July 2026, along with 15 deficiencies.

Records from 2019 to 2026. Most recent: inspection, 6 July 2026.

Built
2019
Last inspected
6 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9817145
9HA5274
1540243
Flag
MALTA
Maury page id
psix-1540243

Inspections, by type

Years with a record 6 calendar years (2019–2026)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it15651 - Convention (Subpart B), Gross Ton
2268 - Dead Weight, Metric Ton
10821 - Displacement, Metric Ton
4707 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 12

6 July 2026 COC-CVE Annual · PSC A
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8430213
8 October 2025 Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 8249954
7 July 2025 PSC A · COC-CVE Annual
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8174161
28 October 2024 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8025878
18 October 2024 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8020938
26 September 2024 COC-CVE Annual
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8009549
5 October 2023 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7811098
30 May 2023 PSC B
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7700669
18 May 2023 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7691522
4 May 2023 PSC A · COC-CVE Initial
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7678758
9 April 2020 In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6937511
20 May 2019 COC-CVE Initial Prep · COC-CVE Initial
Administrative · Activities Europe · Activity 6688326

Deficiency record · 15

07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 July 2026 Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, or where it is possible to assign two or more classifications to a space, it shall be treated as a space within the relevant category having the most stringent boundary requirements. Carpenter workshop Deck 4 fwd is a category 13 space where storage of flammables is prohibited. PSCO observed rubbing alcohol, WD-40, cutting fluid (flammable liquids) stored in the carpenter workshop. 74 SOLAS 20 II-2/9.2.2.3.2.2
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 July 2026
Resolution: Flammable materials removed during exam.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 July 2026 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, a door designed to re-open upon contacting an object in its path shall re-open not more than 1 m from the point of contact. PSCO observed sliding fire door 7310.3 failed to reopen after contacting object. 74 SOLAS 20 II-2/9.4.1.1.5.11
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 July 2026
Resolution: Vsl repaired prior to conclusion of exam.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 July 2026 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed potable water dosing pump with exposed wiring covered with electrical tape in engine room A starboard side. 74 SOLAS 20 II-1/45.1.3
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 July 2026
Resolution: Crew wired into junction box; corrected during exam.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 July 2026 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed dead ended wires of unknown origin coiled near emergency lighting fixture aft of rescue boat port side on deck 5. 74 SOLAS 20 II-1/45.1.3
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2026
Resolved 24 July 2026
Resolution: Receieved class report attesting to repair.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 6 July 2026 Resolved
Two means of escape shall be as widely separated as possible and the doors leading form such means of escape shall be in a position from which access is provided to the appropriate lifeboat and liferaft embarkation decks. PSCO observed both port and starboard escape hatches from steering gear compartment were seized and unable to open. 74 SOLAS 20 II-2/13.4.1.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2026
Resolved 24 July 2026
Resolution: Receieved class report attesting to repair.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 July 2026 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10 s from the beginning of their movement. PSCO observed multiple fire doors in stairway enclosures, main vertical zones and galley boundaries faster then 5 seconds. Fire Door numbers: 2223.1, 2223.1, 2213.1, 2306.1, 2307.1, 2315.2, 2315.1, 3200.3, 3323.1, 4328.2, 4317.1, 4321.1. 74 SOLAS 20 II-1/45.1.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2026
Resolved 24 July 2026
Resolution: Received class report attesting to repair.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 July 2025 Resolved
07105 74 SOLAS 20 II-2/9.4.1.1.5.1 10C Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be cabable of closing with an angle of inclination of up to 3.5 degrees opposing closure. Fire doors 7217.1, 8407.5, 2223.1 and 2223.2 did not close or latch.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 July 2025
Resolved 7 July 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 September 2024 Resolved
For fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40s and no less than 10s from the beginning of their movement. PSCO observed the following doors close in less than 10 seconds: MVZ door 3323.1, stairway door 2306.1, and galley doors 4321.1, 4319.3, 5406.2.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 17 October 2024
Resolution: Photoluminescent strips were applied.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 September 2024 Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. PSCO observed stairway in escape route from deck 2 provisions to deck 3 missing low location lighting or photoluminescent strip.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 17 October 2024
Resolution: Received class report attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 26 September 2024 Resolved
Spaces are classified according to their fire risk as shown in categories (1) to (14). Electrical room 2212 is classified as a category (10) spaces where storage of combustibles is prohibited. PSCO observed installed storage racks holding multiple cardboard boxes.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2024
Resolved 26 September 2024
Resolution: Cardboard boxes were removed prior to the exam being completed to the satisfaction of the team departure from Exam.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 September 2024 Resolved
Waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. PSCO observed combustible waste receptacles for paper and plastic waste in deck 3 galley.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 26 September 2024
Resolved 26 September 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 October 2023 Resolved
Vessel lost propulsion on stbd engine at Mackinac Island while approaching anchorage. Vessel crew was able to restore power to engine.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 5 October 2023
Resolved 5 October 2023
Resolution: Received attestation that crew was able to restore power.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 4 May 2023 Resolved
The company should establish and maintain procedures to control all documents and data which are relevant to the safety management system. Vessel failed to implement its SMS with respect to cyber risk management. Password & username openly displayed on laptop that was used to check in guests at the main gangway. 74 SOLAS 20 IX/3.1 - ISM CODE A.11.1
Action required: 10 - Deficiency Rectified
Due 4 May 2023
Resolved 4 May 2023
Resolution: Vessel removed username and password from being openly visible. Ship security officer revisited company cyber security procedures and provided training to crew.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 May 2023 Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. Escape route from provision area on deck 2 main vertical zone 4 was not fitted with low location lighting or photoluminescent strips. 74 SOLAS 20 ii-2/13.3.2.5.1.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 4 May 2023
Resolved 4 May 2023
Resolution: Photoluminescent strips were satisfactorily installed in escape route.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 May 2023 Resolved
The construction of doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. PSCO observed escape doors 2321 & 2316 fitted in "A" class boundaries in engine space A not latching closed.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 May 2023
Resolved 4 May 2023
Resolution: Crew adjusted spring setting on fire doors that affects the rate at which the door swings closed to ensure proper seating of the door when closed, meeting the class "A" boundary.