SEA TITAN

SEA TITAN is a 2014 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2019, most recently in November 2025, along with 50 deficiencies and 1 operational control.

Records from 2019 to 2025. Most recent: inspection, 17 November 2025.

Built
2014
Last inspected
17 November 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 November 2025
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2019–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK6403
1540244
Flag
UNITED STATES
Maury page id
psix-1540244

Documentation record

Registered dimensions (L × B × D)46.0 ft × 16.0 ft × 9.0 ft
Registered tonnagegross 44 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWTON BOATS INC · SLIDELL, LA, UNITED STATES · built 2014
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portFAJARDO, PR
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Simplified, Gross Ton
35 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 15

17 November 2025 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8268425
5 May 2025 Administrative Inspection · Examination of Repairs · Damage Survey · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8128987
16 September 2024 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7999850
11 October 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7800263
27 June 2023 Administrative Inspection · Examination of Repairs · Drydock Exam · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7721935
1 March 2023 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7643822
1 February 2023 Plan Review "T" Boat
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7630641
11 January 2023 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7619749
10 January 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7618704
13 January 2022 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7377920
22 December 2021 Damage Survey · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7371788
7 June 2021 Internal Structural Exam · Hull Examination · Deficiency Check · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7217707
7 January 2021 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7120884
13 September 2019 Initial Certification · Simplified Stability Test · Plan Review "T" Boat · Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6810367
3 June 2019 Hull Examination · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6699476

Deficiency record · 50

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 November 2025 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. The starboard side fuel-shut-off valve did not closed completely. Prove the full closing of the fuel shut-off valve. 46 CFR 182.455 (b)(4) Code 17C.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 November 2025
Resolution: New attachemnt plate was changed, tested fully operational.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 17 November 2025 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Area of FRP fractures/delamination were found in the collision bulkhead, under deck, and starboard side of the side shell and collision bulkhead as indicated during the exam. Conduct proper FRP repairs to the satisfaction of an attending USCG Marine Inspector. 46 CFR 177.100 Code 50 (30 Days).
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 December 2025
Resolution: Repaired
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 May 2025 Resolved
Repair delamination of the swim platform. 46CFR1769.600
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2025
Resolution: Repaired in kind.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 May 2025 Resolved
Delamination found under deck, starboard side engine room, towards the forward bulkhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2025
Resolved 17 June 2025
Resolution: Repaired.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 September 2024 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in A space with a through-hull fitting below the deepest load waterline, such as a lazarette. High water bilge both visual and audio alarms were found inoperable in the steering compartment (lazarette). 46 CFR 182.530(a)(1). Code 17C.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2024
Resolution: BIlge high water alarms visual and audio were tested and found operable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 September 2024 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. The steering compartment bilge pump manual operation actuator button and LED indicator at the operating station was found inoperable. 46 CFR 182.530(a)(c), code 17C.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2024
Resolution: Tested the bilge pump manual contril and visual led and were found operable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 September 2024 Resolved
All engines must be water cooled and The engine head, block, and exhaust manifold must be water-jacketed and cooled by water from a pump that operates whenever the engine is operating. Starboard side main diesel engine heat exchanger was found to have a coolant water leak. 46 CFR 182.420(a)(1), Code 17C.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2024
Resolution: Heat exchanger cooling water leak was repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 16 September 2024 Resolved
A hatch exposed to the weather must be watertight. Forward, mid and aft hatches were found leaking water inside the compartment upon testing with water poured on top with the fire buckets. 46 CFR 179.360 Code 17C.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2024
Resolution: Verified access hatches and all were found not leaking water after testing.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 September 2024 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station:(1) A light to indicate discharge;(2) An audible alarm that sounds upon discharge; and(3) A means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section. As stated by the master, the pre-engineered fixed gas fire suppression system operation controls at the operating station was found inoperable prior the COI exam being conducted in the morning, and replaced prior ending the exam. Control were tested and found fully operational. 46 CFR 181.420 (b) Code 17C.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2024
Resolution: Controls were replaced and re-tested prior finishing the exam, found operational.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 16 September 2024 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. Starboard side fuel shut-off valve was found inoperable upon actuation. Fuel shut-off valve was repaired prior ending the exam, re-tested and found operational. 46 CFR 182.455 (b)(4), code 17C.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2024
Resolution: Cleared prior finishing the exam, fuel valve was repaired and retested and found fully operational.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 September 2024 Resolved
For fixed-gas fire extinguishing systems, the owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Provide a fire servicing report attesting the type of inspection or examination was conducted to the pre-engineered fire suppression system. 46 CFR 176.810 (b)(1), code 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2024
Resolved 18 September 2024
Resolution: Received servicing report attesting what type of inspection was conducted for the clean agengt cilynder.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 September 2024 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. Provide by the upper deck entranceway with maximum allowed number of passengers permitted in the upper deck. 46 CFR 185.602 (g), code 16 C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2024
Resolved 24 September 2024
Resolution: Number was posted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 September 2024 Resolved
A drip pan fitted with flame screen must be installed under gasoline strainers. Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. Fuel filters does not have fire resistant bowls. 46 CFR 182.455 (6), coe 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2024
Resolved 24 September 2024
Resolution: Flame arested cup was provided for both filters.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 September 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Starboard side aft deck stanchion was found broken/loose at its base. 46 CFR 176.830, code 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2024
Resolved 24 September 2024
Resolution: Stanchion base screw was secured.
08 - Alarms › N/A - No Subsystem › UMS - alarms
Issued 16 September 2024 Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. Dead-end wires were found in the middle compartment, as identified during the exam. 46 CFR 183.220, code 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2024
Resolved 24 September 2024
Resolution: Dead-end cables were removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 September 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing machinery failure, and personnel injury. The temperature gauge at the operating station for the starboard side main diesel engine was found not working properly. 46 CFR 182.100, code 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2024
Resolved 26 September 2024
Resolution: Electrical contacs were cleaned and temp gauge was found propeerly working.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 16 September 2024 Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3 he operator must secure each Type III device in a manner which prevents discharge of sewage. Acceptable methods of securing the device include—(1) Closing each valve leading to an overboard discharge and removing the handle;(2) Padlocking each valve leading to an overboard discharge in the closed position; or(3) Using a non-releasable wire-tie to hold each valve leading to an overboard discharge in the closed position. Type III sewage holding tank was found leaking into the bilge. 33CFR 159. Code 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2024
Resolved 24 September 2024
Resolution: Holding tank leak eas corrected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 September 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Engine room forward and aft bulkheads were found to have penetrations with electrical cables leading to aft steering and mid compartments without proper seal. 46 CFR 177.100 code 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2024
Resolved 25 September 2024
Resolution: Penetrations were sealed by a fire retardant expansion foam and fire retardant sealer.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 October 2023 Resolved
Each vessel that operates beyond three miles from the coastline must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB. EPIRB battery on board expired in February 2023. 46 CFR 180.64
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2023
Resolved 27 December 2023
Resolution: Received photographic evidence of the new EPIRB battery. Expiration date December 2029.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 October 2023 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate high water level. Aft bilge alarm light did not activate when bilge float was activated. 46 CFR 182.530(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2023
Resolved 6 January 2024
Resolution: Verified aft bilge alarm light was working properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 October 2023 Resolved
Each floating waterlight on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 50 pounds and allow the waterlight to be quickly disconnected from the ring life buoy. Ring buoy on board was missing corrosion-resistant clip. 46 CFR 180.70 d(3)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2023
Resolved 30 October 2023
Resolution: Clip replaced
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 3 July 2023 Resolved
050109: Title 47 Code of Federal Regulations (CFR) Part 80, requires that all passenger vessels, regardless of size, must be in compliance with the rules applicable and operating in Sea Area A1, must have upgraded to VHF-DSC Class A radio, either properly connected to a GPS receiver or have a VHF-DSC Marine Radio with an integral GPS. Vessel VHF-DSC radio installed on board was found not displaying GPS coordinates. 46CFR Part 80. 16C.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2023
Resolved 29 August 2023
Resolution: FCC VHF radio was found to have displayed coordinates and MMSI number.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 June 2023 Resolved
99101: The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. The portside handrail, following the portside stern diver, its support base was found lose with minor damage to the FRP under deck. 46 CFR 176.840
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 July 2023
Resolved 3 July 2023
Resolution: Repair solid and not moving.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 June 2023 Resolved
02108: On a nonmetallic vessel, the enclosures and frames of electrical equipment must be bonded together to a common ground by a normally non-current carrying conductor. Vessel's ground wires was found disconnected, damaged due to corrosion of the terminal and cable insulation material was found deteriorated in steering, engine and mid compartments. 46 CFR 183.372
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 July 2023
Resolved 3 July 2023
Resolution: Electrical cables and ground cables have been repair, secured and properly cleaned and connected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 June 2023 Resolved
02108: All cable and wires must be protected from the weather. Clean electrical cable connectors and replace those that were found corroded at the terminal strips in mid compartment and engine rooms. 46 CFR 183.340.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 July 2023
Resolved 3 July 2023
Resolution: All electrical cables has been found cleaned and properly connected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 June 2023 Resolved
13103: Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. Gauges at the operating station were found with protective cover damaged, and other hanging underneath the operating station. 46 CFR 182.410(b).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 July 2023
Resolved 3 July 2023
Resolution: All gauges RPM, Lube, water temp and RPMS have been tested with the engines on and found all operational.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 27 June 2023 Resolved
02101: A hatch exposed to the weather must be watertight. Clean all three watertight hatches rubber gasket seals and the frame on which it makes contact. 46CFR179.360.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 July 2023
Resolution: All 3 hatches gaskets and frames have been cleaned and foud watertight when tested.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 June 2023 Resolved
07109: A space containing propulsion machinery bust be equipped with a fixed gas fire extinguishing system. Engine room bulkhead penetrations must be sealed to prevent the passage of air inside the protected space. 46CFR181.400.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 3 July 2023
Resolution: Engine room bukhead penetrations have been properly sealed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 January 2023 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. The vessel life float was discolored and over 20 % of the vinyl layer was deteriorated. The retro reflective SOLAS tape was no longer reflective and requires new tape on all sides of the life float. The metal ring within the center webbing was broken.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2023
Resolved 1 March 2023
Resolution: Life float was painted with orange vinyl paint, retro reflective material was added to all sides, and the broken joint on the metal ring was welded within the netting.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 January 2023 Resolved
The float-free link must be secured to the painter at one end and to the vessel on the other end. The float-free link was not attached to the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2023
Resolved 17 January 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 January 2023 Resolved
Each ring life buoy must be marked with Type II retro-reflective material. The ring life buoy was missing the required retro-reflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2023
Resolved 17 January 2023
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 10 January 2023 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date of which the unit is installed. A newly installed hydrostatic release unit for the EPIRB was not properly marked with the expiration date.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2023
Resolved 27 January 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 January 2023 Resolved
A vessel not required to have a power pump must three 2.5gal fire buckets with attached lanyard. The words "FIRE BUCKET" must be stenciled in a contrasting color on each bucket. One fire bucket was not properly stenciled, and all three fire buckets were missing a lanyard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2023
Resolved 22 January 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 January 2023 Resolved
Each vessel must be equipped with at least two operable portable battery lights. The vessel only had one operable flashlight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2023
Resolved 23 January 2023
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 13 January 2022 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. The vessel's hydrostatic release unit was expired. Vessel is limited to voyages not more than 3 NM from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2022
Resolved 17 January 2022
Resolution: Vessel representative provided picture of new installed hydrostatic release.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 January 2022 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: (1) A light to indicate discharge. The visual light located at the operating station was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2022
Resolved 24 February 2022
Resolution: Vessel owners installed a new panel at the operating station which has an operable light to indicate discharge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 January 2022 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. The visual alarm located at the operating station for the steering compartment is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2022
Resolved 17 January 2022
Resolution: Received evidence of functioning bilge alarm light at operating station
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 13 January 2022 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. The maximum number of passengers permitted on the second deck was not marked.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2022
Resolved 26 January 2022
Resolution: Received evidence of upper deck entranceway properly marked.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 13 January 2022 Resolved
At each vessel inspection all observed unsafe practices and other hazardous situations must be corrected. Two (02) FRP fractures were found that require repair: 1)Fracture at the steering compartment overhead in-way-of (IWO) the port stringer; and 2)fracture at the top left corner of the center transverse open bulkhead.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2022
Resolved 24 February 2022
Resolution: MI's inspected satisfactory fiberglass repair 02 affected areas.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 13 January 2022 Resolved
At each vessel inspection all observed unsafe practices must be corrected. There was an opening located at the starboard quarter at the bulwarks that allowed water to enter and accumulate within the swim platform.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2022
Resolved 24 February 2022
Resolution: The opening on the bulwark was glassed, sealed and painted to the satisfaction of the the inspectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 December 2021 Resolved
Propulsion machinery must be suitable in type and designed for propulsion requirements of the hull in which it is installed and capable of operating at constant marine loads under such requirements without exceeding its designed limitations. Vessel captain indicated that unusual vibrations occurred when the vessels was being operated at higher RPMs. Prove proper operation of both port and starboard main diesel engines upon satisfaction of an attending USCG Marine Inspector, prior departure with passengers for hire.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 January 2022
Resolved 26 January 2022
Resolution: Both propeller have been sent to a repair shop and refctified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 January 2021 Resolved
A submersible electric bilge pump may be used as a power bilge pump only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, provided that the pump is listed by an independent laboratory as meeting the requirements in UL 1113. UL reference was not present on submersible bilge pump located in steering compartment. Owner/operator shall provide documentation of existing pump that meets requirements of UL1113 or replace with one that does.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2021
Resolved 22 January 2021
Resolution: Owner/operator replaced bilge pump with a new UL1113 pump
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 January 2021 Resolved
A vessel of more than(26 feet)in length, but not more than(65 feet), must carry a minimum of one life buoy of not less than (24 inches) in diameter. At least one ring life buoy must be fitted with a lifeline. Each lifeline on a ring life buoy must be buoyant, be of at least (60 feet) in length, be non-kinking, have a diameter of at least (5/16 inch), have a breaking strength of at least(1,124 pounds), and be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Repair or replace worn and deteriorated 24" Life Bouy and lifeline.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2021
Resolved 22 January 2021
Resolution: Owner/operator replaced old bouy and life line with new 24"bouy as per requirement.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 7 January 2021 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Emergency instructions were not mounted at operating station during inspection.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2021
Resolved 22 January 2021
Resolution: Emergency procedures posted at the operating station. Picture attached in "Documents" section.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 15 October 2019 Resolved
A vessel certificated to operate on a limited coastwise route in warm waters must be provided with life floats that will accommodate at least 50% of the total persons permitted on board. The vessel was found to be fitted with buoyant apparatuses approved under 160.010 which are not permitted. Vessel is restricted to operations not further than 3 miles from shore until the vessel is fitted with life floats approved under 160.027.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 8 January 2020
Resolution: Life floats are onboard and installed correctly.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 October 2019 Resolved
Vessels must comply with the applicable FCC regulations contained in 47 CFR Part 80. The vessel was found to be missing the FCC Station License.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2019
Resolved 22 October 2019
Resolution: Received copy of FCC Station Authorization.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 October 2019 Resolved
Vessels must comply with the applicable FCC regulations contained in 47 CFR Part 80. The vessel's VHF radio does not have the assigned MMSI number entered.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2019
Resolved 8 May 2020
Resolution: MMSI number is entered into VHF radio.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 15 October 2019 Resolved
The name of the vessel must be marked in clearly legible letters on each life float paddle. The required markings on the paddles were missing.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2019
Resolved 22 October 2019
Resolution: Vessel name was marked on the life float paddles.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 October 2019 Resolved
Machinery and equipment on the vessel must be suitable for the vessel and its operation and for the purpose intended. The port side fuel tank flexible hose fitting was found to be loose and showed signs of a small diesel leak.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2019
Resolved 8 May 2020
Resolution: Flexible hose was fitted properly.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2019 Resolved
Cable and wiring must be installed with metal supports spaced not more than 610 mm (24 inches) apart in such a manner as to avoid chafing. Observed bundles of wiring in sewage tank space secured with zip ties. Install metal supports every 610 mm.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2019
Resolved 22 October 2019
Resolution: Verified that all electrical wiring was properly supported.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.