MAURY USCG vessel records
← All vessels

GRANDE TORINO

GRANDE TORINO is a 2018 freight ship. The Coast Guard has recorded 18 inspections since 2018, most recently in April 2024, along with 6 deficiencies and 7 operational controls.

Records from 2018 to 2024. Most recent: inspection, 2 April 2024.

Built
2018
Last inspected
2 April 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 April 2024
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2018–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9782675
1540833
Flag
ITALY
Maury page id
psix-1540833

Documentation record

Tonnage as PSIX records it65255 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

2 April 2024 PSC A
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7888257
30 January 2023 PSC B · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7628895
15 September 2022 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7559397
3 September 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7550025
2 June 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7466326
2 May 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7442430
21 October 2021 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7337174
5 October 2021 Special
Type not classified · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7327282
8 July 2021 MARPOL Annex VI Survey · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7249842
28 August 2020 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7044972
31 July 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7020874
7 February 2020 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6906042
6 February 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6904536
5 February 2020 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6904138
30 December 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6880661
6 December 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6865789
7 October 2019 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6828026
26 December 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6602719

Deficiency record · 6

11 - Life Saving Appliances › N/A - No Subsystem › Emergency equipment for 2-way comm.
Issued 30 January 2023 Resolved
At least three two-way VHF radios... shall be provided.. and conform to performance standards not inferior to those adopted by the Org. All three radios had expired batteries. 74SOLAS(20) III/6.2.1.1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2023
Resolution: Replaced batteries
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 January 2023 Resolved
An efficient bilge pumping system shall be provided, capable of pumping from and draining any watertight compartment. Crew is using fabricated temporary flexible hose and fittings to connect bilge water tank to sludge pump to discharge due to the inefficient pumping capacity of the bilge pump. 74SOLAS(20) II/I/35-1.2.1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2023
Resolution: See class report
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 30 January 2023 Resolved
In meeting these requirements, the Company should ensure that the inspections are held at appropriate intervals. SMS requires monthly inspection of cargo securing equipment, crew is conducting quarterly inspections. 74SOLAS(20)IX/3.1 ISM CODE 10.2.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 March 2023
Resolution: Company stated that the ship was using an outdated instruction on the frequency of inspections for their cargo securing devices. This outdated instruction was removed and replaced with the correct instruction per the companies procedures.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 30 January 2023 Resolved
The Company should establish procedures... for key shipboard operations... concerning protection of the environment. Crew is using unapproved Piping to increase rate of discharge of bilge water to reception facility. 74SOLAS(20) IX/3.1 ISM CODE 7
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2023
Resolution: See class report
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 January 2023 Resolved
To prevent the ignition of combustible materials... the ignitability of combustible materials shall be restricted. Cardboard boxes are being stored in the oil purifying space. 74SOLAS(20) II-/4.1
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 30 January 2023
Resolution: PSCO's observed cardboard was removed from space.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 December 2019 Resolved
Each Operator or agent of a vessel with a capacity of 250 or more barrels of fuel oil, cargo, hazardous material shall designate, either by name or by position in the crew, a person in charge(PIC) of each transfer to or from the vessel. Port State Control Examiner discovered the vessel's transfer procedures stated the PIC must be in attendence of each transfer but did not designate the PIC by name or title. 50c 33CFR155.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2020
Resolved 30 December 2019
Resolution: Received revised Oil Transfer Procedures that designate the Chief Engineer by position as the Person In charge (PIC).

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.