MAURY USCG vessel records Sign in
← All vessels

BIG JOHN

BIG JOHN is a 1977 passenger vessel (inspected). The Coast Guard has recorded 62 inspections since 1990, most recently in May 2026, along with 43 deficiencies.

Records from 1990 to 2026. Most recent: inspection, 21 May 2026.

Built
1977
Last inspected
21 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH9283
154144
Flag
UNITED STATES
368419550
Maury page id
psix-154144

Inspections, by type

…with no type recorded7
Years with a record 33 calendar years (1990–2026)
The 62 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)48.0 ft × 17.1 ft × 9.6 ft
Registered tonnagegross 52 / net 42
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderG & S BOATS · DESTIN, FL, UNITED STATES · built 1977
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 2 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it52 - Regulatory (Subpart C or D), Gross Ton
42 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ3745MMSI 368419550 · active · compulsorily equipped · granted 16 May 2025, expires 16 May 2035
WDH9283MMSI 367666470 · expired · compulsorily equipped · granted 11 April 2015, cancelled 24 May 2025
WCQ3460MMSI 367012780 · expired · compulsorily equipped · granted 20 January 2005, cancelled 9 May 2015 · licensed under a name not among this hull’s recorded names (not shown)
WCD8456MMSI not assigned · expired · compulsorily equipped · granted 14 February 1994, cancelled 25 April 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 62

21 May 2026 Administrative Inspection · Annual Inspection · Vessel Attendance
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8380924
8 May 2026 Type not recorded
No type recorded · USCGC OLIVIA HOOKER (WPC 1161) · USCG Heartland District (CGD-H) · Activity 8369684
30 January 2026 Vessel Attendance · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8303919
28 April 2025 Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 8131098
21 April 2025 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8103383
6 May 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7907930
27 February 2024 Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7871593
7 February 2024 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7859767
18 May 2023 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7686081
16 May 2022 Annual Inspection · Simplified Stability Test
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7459957
2 May 2022 Construction Oversight
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7443659
21 March 2022 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7417766
20 October 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7336233
18 May 2021 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7201035
5 May 2020 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6946645
3 March 2020 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6919992
19 September 2019 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6816596
6 August 2019 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6776601
29 May 2018 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6421774
8 February 2018 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6346290
27 July 2017 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6219402
18 July 2016 DAPI Audit · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5837521
28 June 2016 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 5922935
24 March 2016 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5999743
24 September 2015 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 5728641
29 May 2014 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4905925
24 May 2012 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4318015
15 May 2012 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4311308
30 March 2010 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3705797
2 February 2010 Internal Structural Exam · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3673720
7 May 2009 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3465210
7 May 2008 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3196375
13 March 2008 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3159069
22 May 2007 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2937005
29 March 2006 Re-Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2611854
7 February 2006 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2593332
8 March 2005 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2306539
10 February 2005 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2289724
31 March 2004 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2034524
9 March 2004 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2022649
13 February 2004 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2009162
11 March 2003 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1758310
6 March 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1742339
26 March 2002 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1597424
21 February 2002 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1488427
29 November 2001 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1075955
13 August 2001 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 1521818
12 March 2001 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1064520
17 February 2000 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1458755
17 August 1999 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 1510050
12 April 1999 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 1510033
25 February 1999 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1420100
12 February 1998 Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1383782
18 February 1997 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1371698
29 February 1996 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1098179
29 February 1996 Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1383190
4 March 1995 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1438298
14 March 1994 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 868711
4 March 1994 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1165615
28 February 1994 Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1165492
12 May 1992 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 955375
13 June 1990 Hull Examination · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 932113

Deficiency record · 43

Engineering › Bilge Water Management System › Interface Detector
Issued 19 July 2016 Resolved
Repair/replace fwd compartment bilge alarm.
Action required: 705 - Other - as specified
Due 3 August 2016
Resolved 19 July 2016
Resolution: Vessel replaced bilge alarm
Lifesaving › Lifefloat › Painter
Issued 19 July 2016 Resolved
Replace lifefloat painter
Action required: 705 - Other - as specified
Due 3 August 2016
Resolved 19 July 2016
Resolution: Vessel replaced painter
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 19 July 2016 Resolved
Prove proper operation of SSB
Action required: 705 - Other - as specified
Due 3 August 2016
Resolved 19 July 2016
Resolution: Vessel repaired and proved proper operation.
Construction/Loadline › Structures › Scuttle
Issued 19 July 2016 Resolved
Repair aft compartment hatch knife edge.
Action required: 705 - Other - as specified
Due 3 August 2016
Resolved 25 July 2016
Resolution: Vessel repaired hatch
Electrical › Lighting (service) › Lighting Fixture
Issued 29 May 2014 Resolved
Lights in E/R need covers affixed
Action required: 705 - Other - as specified
Due 4 June 2014
Resolved 31 May 2014
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 29 May 2014 Resolved
Tighten the starboard propellor shaft
Action required: 705 - Other - as specified
Due 4 June 2014
Resolved 31 May 2014
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 29 May 2014 Resolved
Clean excess oil in E/R bilges
Action required: 705 - Other - as specified
Due 4 June 2014
Resolved 31 May 2014
Documentation › Certificates/Documents › Certificate of Inspection
Issued 30 March 2010 Resolved
Vessel has exceeded its expiration date on its Certificate of Inspection. In accordance with 46 CFR 176.404(a)(b) the vessel will be required to complete an inspection for renewal of a COI prior to carrying more than 6 passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2010
Resolution: COI Inspection was conducted and completed.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 2 February 2010 Resolved
Tighten railing on port side of pilot house in accordance with 46 CFR 177.900 and to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2010
Resolved 9 March 2010
Resolution: Railing on port side of pilot house was properly secured.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 2 February 2010 Resolved
Renew fuel tank shut-off handles in accordance with 46 CFR 182.455(b)(4) and to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2010
Resolved 9 March 2010
Resolution: Fuel tank shut-off handles were properly renewed, and independent operation was proven without interference from the other handles.
Engineering › Sea-water System (primary cooling) › Piping
Issued 2 February 2010 Resolved
Renew flexible non-metallic hose for generator raw water suction in accordance with 46 CFR 182.720(e) and to the satisfaction of the attending marine inspector.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2010
Resolved 9 March 2010
Resolution: The flexible non-metallic hose for generator raw water suction was properly renewed with an approved type.
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 2 February 2010 Resolved
Install thimble in anchor line arrangement in accordance with 46 CFR 184.300 and to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2010
Resolved 9 March 2010
Resolution: A thimble was properly installed in the anchor line.
Deck/Cargo › Mooring/Anchoring › Anchor Shackle
Issued 2 February 2010 Resolved
Free up shackles in anchor line arrangement in accordance with 46 CFR 184.300 and to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2010
Resolved 9 March 2010
Resolution: Shackles were proven to be free and operable.
Deck/Cargo › Holds/Tanks › Hatch
Issued 2 February 2010 Resolved
Repair or renew hatch combing into steering gear room and prove tightness using host test at 30 psi in accordance with and to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 March 2010
Resolved 9 March 2010
Resolution: The hatch was hose tested and was watertight.
Construction/Loadline › Hull › Hull Plating
Issued 2 February 2010 Resolved
Renew deteriorated deck and associated support framing on main deck forward bow in way of forward deck hatch in accordance with 46 CFR 177.300(c) and to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2010
Resolved 9 March 2010
Resolution: The deteriorated deck and associated support framing on main deck forward bow in way of forward deck hatch was properly renewed. The integrity of the repair was verified by visual examination and a hose test to ensure watertight integrity.
Deck/Cargo › Towing › Tackle
Issued 2 February 2010 Resolved
Tighten through hull bolts for cleats on port and starboard bow in accordance with 46 CFR 184.300 and to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2010
Resolved 9 March 2010
Resolution: All cleat bolts on the port and starboard bow were properly tightened.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 2 February 2010 Resolved
Renew port and starboard cutlass bearings to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2010
Resolved 9 March 2010
Resolution: Port and starboard cutlass bearings were renewed.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 2 February 2010 Resolved
Renew engine room deckhead transverse supports aft of engines in accordance with 46 CFR 177.300(c) and to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2010
Resolved 9 March 2010
Resolution: The engine room deckhead transverse supports aft of engines were properly renewed with new members.
Lifesaving › Lifebuoys › Serviceable
Issued 7 May 2009 Resolved
Replace ring life buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2009
Engineering › Fuel Oil Service System › Hose
Issued 7 May 2009 Resolved
Place chaffe gear on lines for oil cooler.
Due 21 May 2009
Resolved 19 May 2009
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 7 May 2009 Resolved
Replace/repair high water alarm wiring for engine room and lazarette (audio and visual alarm sounds off of same indicator).
Due 21 May 2009
Resolved 19 May 2009
Navigation › Piloting/Steering › US Coast Pilot
Issued 7 May 2009 Resolved
Provide current coast pilot.
Due 21 May 2009
Resolved 19 May 2009
Engineering › Fuel Oil Service System › Filter
Issued 10 February 2005 Resolved
Install suitable marine type fuel oil strainer on starboard propulsion engine (46 CFR 182.455 (b)(6).
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 March 2005
Resolved 8 March 2005
Resolution: Completed to the satisfaction of the attending Coast Guard Marine Inspector.
Engineering › Fuel Oil Service System › Hose
Issued 10 February 2005 Resolved
Remove all hose clamps that rely on spring tension for compressive force on auxiliary generator fuel oil flex hose assemblies (46 CFR 182.720).
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 March 2005
Resolved 8 March 2005
Resolution: Completed to the satisfaction of the attending Coast Guard Marine Inspector.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 10 February 2005 Resolved
Remove paint from heat detector in machinery space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 March 2005
Resolved 8 March 2005
Resolution: Completed to the satisfaction of the attending Coast Guard Marine Inspector.
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 February 2005 Resolved
Install flame resistant insulation on non-metallic vital piping (machinery cooling) in machinery space (46 CFR 182.40(a)(2).
Action required: 705 - Other - as specified
Due 10 March 2005
Resolved 8 March 2005
Resolution: Completed to the satisfaction of the attending Coast Guard Marine Inspector.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 February 2005 Resolved
Install suitable guards for propulsion engine accessory drive belts (46 CFR 177.35-15).
Action required: 705 - Other - as specified
Due 10 March 2005
Resolved 8 March 2005
Resolution: Completed to the satisfaction of the attending Coast Guard Marine Inspector.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 10 February 2005 Resolved
Provide current copies or excerpts from navigation safety publications required by 46 CFR 184.420
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 March 2005
Resolved 8 March 2005
Resolution: Completed to the satisfaction of the attending Coast Guard Marine Inspector.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 10 February 2005 Resolved
Provide suitable means of closing machinery space ventilation cowls. (46 CFR 181.20-35).
Action required: 705 - Other - as specified
Due 10 March 2005
Resolved 8 March 2005
Resolution: Completed to the satisfaction of the attending Coast Guard Marine Inspector.
Engineering › Bilge Water Management System › Hose
Issued 10 February 2005 Resolved
Provide suitable discharge hose for hand bilge pump (46 CFR 182.25-10(e).
Action required: 705 - Other - as specified
Due 10 March 2005
Resolved 8 March 2005
Resolution: Completed to the satisfaction of the attending Coast Guard Marine Inspector.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 13 February 2004 Resolved
Repair pin hole leaks in both main diesel exhaust risers. LEGACY COMPONENT DESC: Piping (exhaust)
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 March 2004
Resolved 9 March 2004
Resolution: Owner repaired pin holes in exhaust risers.
Navigation › Piloting/Steering › US Coast Pilot
Issued 6 March 2003 Resolved
Provide up to date charts and publications as required by 46 CFR 184.420.
Due 6 April 2003
Resolved 11 March 2003
Resolution: Current US Coast Pilot onboard.
Communications › Radio Communications
Issued 6 March 2003 Resolved
Provide an Emergency Broadcast Placard as required by 46 CFR 184.506.
Due 6 April 2003
Resolved 11 March 2003
Resolution: Emergency Broadcast Placard onboard.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 March 2003 Resolved
Provide a machinery guard over alternator, inboard by the starboard main engine, as required by 46 CFR 177.960.
Due 6 April 2003
Resolved 11 March 2003
Resolution: Guard installed over alternator.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 March 2003 Resolved
Provide guard over flourescent light fixtures as required by 46 CFR 183.015 or 46 CFR 183.410.
Due 6 April 2003
Resolved 11 March 2003
Resolution: Flourescent light covers installed.
Construction/Loadline
Issued 17 February 2000 Resolved
46 CFR 176.802 - REPLACE FRAMES #2 & #3 PORT SIDE ENGINE ROOM.
Condition: Unknown
Due 17 February 2000
Resolved 11 May 2000
Construction/Loadline
Issued 17 February 2000 Resolved
46 CFR 176.802 - REMOVE ALL ANGEL HAIR FROM INTERNAL WOOD FOR FURTHER INSPECTION.
Condition: Unknown
Due 17 February 2000
Resolved 11 May 2000
Engineering
Issued 17 February 2000 Resolved
46 cfr 182.455 - REPLACE HANDLES ON FUEL BALL VALVES IN AFT COMPARTMENT ANDSTARBOARD SIDE ENGINE ROOM.
Condition: Unknown
Due 17 February 2000
Resolved 11 May 2000
Construction/Loadline
Issued 4 March 1994 Resolved
PROVE WATERTIGHTNESS OF COLLISION BULKHEAD AND THE MEANS TO DEWATER SPACE FORWARD OF THE COLLISION BULKHEAD.
Condition: Unknown
Due 18 March 1994
Resolved 5 August 1994
Construction/Loadline
Issued 4 March 1994 Resolved
REPAIR COLLISION BULKHEAD TO MAINTAIN WATERTIGHT INTEGRITY OR INSTALL BILGEPIPING SYSTEM IAW 46 CFR 182.25-5.
Condition: Unknown
Due 18 March 1994
Resolved 5 August 1994
Unknown
Issued 13 June 1990 Resolved
PROVIDE THE FOLLOWING PLANS FOR REVIEW AND APPROVAL A) REVISED 12V DC WIRING B) ARRANGEMENT OF PIPING C) BULKHEAD, DECK PENETRATION AND SHELL CONNECTIONS
Condition: Unknown
Due 13 June 1990
Resolved 13 June 1990
Documentation
Issued 13 June 1990 Resolved
PROVIDE AND PLACE ONBOARD A VALID FCC SAFETY RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 13 June 1990
Resolved 13 June 1990
Documentation
Issued 13 June 1990 Resolved
PROVIDE AND PLACE ONBOARD A VALID FCC STATION LICENSE.
Condition: Unknown
Due 13 June 1990
Resolved 13 June 1990

Ownership record