MAURY USCG vessel records
← All vessels

HARBOR HOPPER

HARBOR HOPPER is a 2019 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2019, most recently in June 2026, along with 16 deficiencies.

Records from 2019 to 2026. Most recent: inspection, 24 June 2026.

Built
2019
Last inspected
24 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 June 2026
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2019–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1542285
Flag
UNITED STATES
Maury page id
psix-1542285

Documentation record

Tonnage as PSIX records it2 - Regulatory (Subpart C or D), Gross Ton
2 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

13 inspections, each with its date, unit and type; 16 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 13

24 June 2026 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 8407543
24 June 2026 Administrative Inspection
Administrative · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 8420345
4 June 2025 Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 8151718
7 November 2024 Deficiency Check
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 8031908
4 April 2024 Deficiency Check · COI Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7885770
17 January 2024 Hull Examination
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7849843
22 June 2023 Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7719789
8 August 2022 Damage Survey
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7528149
19 May 2022 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7454367
8 July 2021 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7249205
14 July 2020 DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7012458
1 April 2019 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6651516
30 January 2019 Construction Oversight · Initial Certification · Deadweight Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6613518

Deficiency record · 16

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 June 2026 Resolved
Vessel only had three of the required six flares onboard. Procure additional three orange or red flares.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 June 2026
Resolved 1 July 2026
Resolution: Rcvd photo of new flares onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 June 2026 Resolved
First aid kit had expired eye wash and antiseptic ointment. Procure new first aid items that are expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2026
Resolution: Rcvd photo of new first aid kit on board.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 4 April 2024 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Provide proof all crew are enrolled in drug testing program.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 April 2024 Resolved
Portable fire extinguishers must be inspected and maintained in accordance with NFPA 10. Annual inspections were expired. Provide proof of annual servicing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 April 2024 Resolved
After loading and prior to departure and at all other times to assure the safety of the vessel, the master shall determine that the vessel complies with all applicable stability requirements in the vessel's trim and stability letter. Found signage attached to railing. Provide proof signage is removed.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2024
Resolution: Banners/signage are removed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 June 2023 Resolved
Portable and semi-portable extinguishers must be inspected and maintained annually. 01 portable extinguisher onboard had not been serviced annnually. Provide proof of servicing or replacement of portable extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2023
Resolution: Received proof of new portable fire extinguisher onboard as required.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 22 June 2023 Resolved
Drug testing consortium enrollment was expired.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2023
Resolved 22 June 2023
Resolution: Received updated/current enrolment letter upon return to the office.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 May 2022 Resolved
Portable watertight containers for distress flares and smoke signals shall be clearly marked in legible contrasting colors at least 1/2" high: DISTRESS SIGNALS
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2022
Resolved 1 June 2022
Resolution: Received evidence of correction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 May 2022 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2022
Resolved 1 June 2022
Resolution: Received evidence of correction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 May 2022 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2022
Resolved 1 June 2022
Resolution: Received evidence of correction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 July 2021 Resolved
Each RLB with a floating waterlight must have a lanyard of 3 ft securing the waterlight around the body of the RLB with a clip allowing quick disconnect. Waterlight connected to RLB by loose knot and D-ring. Provide means to securely attach light to RLB with a clip.
Action required: 10 - Deficiency Rectified
Resolved 9 July 2021
Resolution: Connected light to body of RLB with clip and 3 ft line. Removed D-ring.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 8 July 2021 Resolved
Marine employer shall comply with requirements of drug and alcohol program and testing. No list of employees enrolled in consortium testing program. Provide proof of enrollment in approved drug and alcohol testing program.
Action required: 10 - Deficiency Rectified
Resolved 9 July 2021
Resolution: Consortium emailed list of employees enrolled in program.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 July 2021 Resolved
Placards containing instructions for the donning and use of PFDs must be posted in area visible to crew and PAX. No placard onboard. Provide appropriate donning placard.
Action required: 10 - Deficiency Rectified
Resolved 14 July 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 July 2021 Resolved
Owner shall conduct inspections and tests for portable FE required by NFPA 10 Chp. 4. No proof of maintenance or inspections. Provide proof of annual FE maintenance.
Action required: 10 - Deficiency Rectified
Resolved 14 July 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 July 2021 Resolved
Abandon ship and man overboard drills and training shall be logged and available for review by USCG on request. Drills not logged. Drill logged today and will be logged in the future.
Action required: 10 - Deficiency Rectified
Resolved 9 July 2021
Resolution: Education given. Drill logged today.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 January 2019 Resolved
Vessel's new owner will be required to complete a "new-to-zone" inspection once the vessel is delivered to its new OCMI zone. The attached CG-835, and the associated worklist, will need to be completed to the satisfaction of the attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2019
Resolved 15 April 2019
Resolution: New to Zone inspection completed and worklist items addressed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.