Records from 2018 to 2026. Most recent: inspection, 17 February 2026.
Inspection history · 13
17 February 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8299909
7 April 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8097111
5 February 2025
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8067665
16 January 2024
COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7848300
2 March 2023
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7644864
21 February 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7639260
9 January 2023
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7620748
13 July 2022
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7505947
3 May 2021
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7189947
22 February 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7144472
5 June 2020
Administrative Inspection · Internal Structural Exam · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6968988
29 April 2019
Annual Inspection · Internal Structural Exam · DAPI Audit · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6671108
19 November 2018
Administrative Inspection · Construction Oversight · Internal Structural Exam · Deadweight Survey · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6618169
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 February 2026
Resolved
Life Jacket signs are worn and need to be updated for locations of adult and child life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 February 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 February 2026
Resolved
Port fuel shut off is super tight and needs to be fixed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 February 2026
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 17 February 2026
Resolved
Water tight container for flares needs to be marked as "DISTRESS SIGNALS"
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 February 2026
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 April 2025
Resolved
PORT Side high water alarm does not work correctly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2025
Resolved 9 April 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 April 2025
Resolved
Vessel needs new FCC safety cert.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2025
Resolved 9 April 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 April 2025
Resolved
Fire buckets need to be properly labeled.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2025
Resolved 9 April 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 January 2024
Resolved
Life ring floating light was not working properly. Make repairs or replace floating light. Vessel is limited to day light hours only until cleared.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2024
Resolved 2 February 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 January 2024
Resolved
Life ring 60' throw line was dry rotted and fraying. Must replace throw line to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2024
Resolved 2 February 2024
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 March 2023
Resolved
Hydrostatic release had just expired last month. Must replace hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2023
Resolved 31 March 2023
Resolution: New Hydrostatic release installed
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 2 March 2023
Resolved
All 4 paddles for both life floats were dry rotted and broken. Must replace all 4 paddles meeting requirements.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2023
Resolved 31 March 2023
Resolution: 4 new paddles onboard
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 July 2022
Resolved
Both life floats are faded and or cracked. Must conduct repairs or replace both life floats.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2022
Resolved 7 December 2022
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 July 2022
Resolved
Anchor light has two light bulbs, one doesn't work. Must replace light bulb to where both work.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2022
Resolved 22 July 2022
Resolution: Replaced aft light bulb. picture showing both bulbs on.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 July 2022
Resolved
EAP requirements are not met for the Chemical testing program. Supervisor must show proof of at least 1 hour training that meets the CG requirements.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2022
Resolved 8 August 2022
Resolution: Supervisor completed a 2 hr course that meets USCG requirements.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 May 2021
Resolved
Anchor light not working. Must repair and test to the satisfaction of the attending CG Marine Inspector.
COLREGS
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 10 May 2021
Resolution: Received pictures of anchor light working. Bulbs replaced. All SAT
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 5 June 2020
Resolved
COD on board is expired. Provide up to date COD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2020
Resolution: Owner received new COD and inspector verified it was on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 June 2020
Resolved
Starboard hull bilge pumps are inoperable. Repair/Renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2020
Resolution: Starboard bilge pump was purchased and renew. Inspector verified all bilge pumps were in good operational order.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 June 2020
Resolved
Port life float needs new reflective material.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2020
Resolution: Port life float reflective material has been renewed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 5 June 2020
Resolved
Coast pilot, light list, and tide tables must be updated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2020
Resolution: All nautical publications have been renewed or replaced on board.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 June 2020
Resolved
Provide logs to track safety gear maintenance (monthly).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2020
Resolution: Logs for safety gear maintenance was created.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 June 2020
Resolved
Provide log for drills quarterly. (MOB, fire and abandon ship)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2020
Resolution: Log for quarterly drills was provided to inspector.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 5 June 2020
Resolved
Vessel is missing 1 2.5 gallon fire bucket. Provide.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2020
Resolution: Missing 2.5 gallon fire bucket was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 29 April 2019
Resolved
Life float must be attached to vessel via weak link.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2019
Resolution: Life float was properly attached.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 29 April 2019
Resolved
Stencil vessel name and float capacity on both sides of life float.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2019
Resolution: Life float was properly marked.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 April 2019
Resolved
Provide a navigational Chart.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2019
Resolution: All charts and publications were provided.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 29 April 2019
Resolved
Provide and post emergency radio placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2019
Resolution: Emergency proceedures were posted.
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 29 April 2019
Resolved
Provide alcohol test strips.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2019
Resolution: Alcohol test strips were provided.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 29 April 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2019
Resolution: Fcc documents were provided.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 April 2019
Resolved
Create log for drills and safety gear maintenance.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2019
Resolution: New logs were created and implemented.