Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it157270 - Dead Weight, Metric Ton 183096 - Displacement, Metric Ton 82305 - Convention (Subpart B), Gross Ton 51195 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 6
24 June 2025Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8166007
15 December 2024PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8045611
23 February 2022COC-TVE Renew · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7396634
26 February 2021Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7146871
23 April 2020COC-TVE Renew · Ballast Water Examination · PSC A
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6940884
22 April 2020Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6942628
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 February 2022Resolved
IN TANKERS, ELECTRICAL EQUIPMENT, CABLES AND WIRING SHALL NOT BE INSTALLED IN HAZARDOUS LOCATIONS UNLESS IT CONFORMS WITH STANDARDS NOT INFERIOR TO THOSE ACCEPTABLE TO THE ORGANIZATION. TEMPERATURE SENSOR ON THE #2 CARGO PUMP HAD AN IMPROPERLY PACKED ELECTRICAL GLAND POTENTIALLY ALLOWING FLAMMABLE VAPORS.
74SOLAS(2020) Ch.II-1/Reg.45.11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 February 2022
Resolution: ETO replaced the cable gland and repacked the temperature sensor gland.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.