CLIPPER ERIS

CLIPPER ERIS is a 2019 tank ship. The Coast Guard has recorded 12 inspections since 2020, most recently in June 2026, along with 8 deficiencies and 2 operational controls.

Records from 2020 to 2026. Most recent: inspection, 15 June 2026.

Built
2019
Last inspected
15 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 June 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2020–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9834727
1542998
Flag
NORWAY
Maury page id
psix-1542998

Documentation record

Tonnage as PSIX records it18044 - Dead Weight, Metric Ton
18898 - Convention (Subpart B), Gross Ton
26599 - Displacement, Ton
5738 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

12 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

15 June 2026 COC-GAS Renew · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8394939
8 August 2025 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8205739
8 August 2025 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8207604
20 June 2025 COC-GAS Annual · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8162971
28 March 2025 In-Service Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8101641
24 March 2025 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8098604
13 June 2024 COC-GAS Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7933888
25 May 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7696439
9 May 2023 Administrative Inspection · PSC B · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7684497
22 April 2022 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7430813
19 April 2021 Deficiency Check · COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7174877
20 March 2020 COC-GAS Renew · PSC A
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6927931

Deficiency record · 8

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 March 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. While transiting inbound near the Delaware River the vessel's main engine #2 cylinder started misfiring. Ensure the main engine is operating properly and the vessel is safe to proceed to the satisfaction of Class and USCG.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 March 2025
Resolved 30 March 2025
Resolution: Technician replaced the No. 2 Fuel Injection Valve on the missfiring cylinder.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 11 May 2023 Resolved
The company should establish procedures, plans, and instructions for key shipboard operations concerning safety of ship and personnel. Shipboard SMS procedure "Deck 3-Carope 0889" contains instructions for fixed gas detection. PSCO observed no instructions onbaord to ensure fixed gas detection system is capable with all cargoes carried as denoted in deficiency #2.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2023
Resolved 24 May 2023
Resolution: Recieved amended operations procedures
09 - Working and Living Conditions › 092 - Working Conditions › Gas instruments
Issued 11 May 2023 Resolved
Gas detection equipment shall be installed and tested IAW recognized standards and shall be suitible for all cargoes carried. PSCO observed fixed gas detection system calibrated with isobutane with no adjustment for carriage of ethylene.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2023
Resolved 24 May 2023
Resolution: Recieved tech report stating system has been set properly for ethelene. Crew was trained on setting procedures.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Other (MARPOL Annex VI)
Issued 19 April 2021 Resolved
The equipment shall be maintained to conform with the provisions of this annex and no changes shall be made in the equipment, systems, fittings, arrangements, or material covered by the survey, without the express approval of the administration. The direct replacement of such equipment and fittings with equipment and fittings that conform with the provisions of this annex is permitted. The vessel reported the variable frequency converter for the vessel's exhaust gas return is not operating as designed. MARPOL (2017) ANNEX IV Reg 5.5.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 May 2021
Resolution: Received Class Report.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 20 March 2020 Resolved
Pressure Relief Valves shall be set and sealed by the Administration or Recognized Organized acting on its behalf. PSCO found broken seal on cargo tank 1 Port. In addition, top bolt was not secured as on the other PRVs. PSCO could not attest that the setting was unchanged. IGC 2016/8.2.6 Action Taken 34ac. Rectify prior to loading Cargo Tank 01.
Action required: 705 - Other - as specified
Resolved 26 March 2020
Resolution: Received Class survey statement. he attending surveyor witnessed a field test of the pilot valve, field test kit on board, in accordance with manufacturer specification, after test the valve has been re-sealed by DNVGL class surveyor.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 20 March 2020 Resolved
Gas detection equipment shall be installed to monitor the integrity of the cargo containement, cargo handling and ancillary system in accordance with IGC 2016 13.6. The fixed gas detection system cabinet readout screen for LEL% sensor is inconsistent with the reading on the sensor's screen inside the cabinet. IGC 2016 13.6.1 Action Taken 34 ac. Rectify Prior to Loading all Cargo Tanks.
Action required: 705 - Other - as specified
Resolved 26 March 2020
Resolution: Received technician's report and Class survey statement attesting to the adjustment and recalibration of the all sensors of the fixed gas detection system.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 20 March 2020 Resolved
Suitable equipment to test and calibrate gas detection equipment shall be carried on board and be used in accordance with the manufacturer's recommendations. PSCO was not able to witness satisfactory test of gas concentrations by volume becasue vessel does not have the required Propoane (by vol. 10%, 15%, 20%) test gas for fixed gas detector capable of measuring gas concentrations of 0% to 100% by volume. IGC 2016 13.6.18 Action Taken: 34ac rectify prior to loading all tanks.
Action required: 705 - Other - as specified
Resolved 26 March 2020
Resolution: Received technician's report and Class survey statement attesting to the adjustment and recalibration of the all sensors of the fixed gas detection system.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 20 March 2020 Resolved
The ship's cargo system operation manual shall be approved by the Administration. The ship's cargo system operation manual has not been approved by the Administration/RO. IGC 2016 18.2.1 Action Taken: 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 March 2020
Resolution: Received Class survey statement attesting to the approval of the vessel's cargo operation manual onboard.