GATOR 4

GATOR 4 is a 2019 passenger vessel (inspected). The Coast Guard has recorded 11 inspections since 2019, most recently in December 2025, along with 21 deficiencies — 2 with no resolution recorded — and 1 operational control.

Records from 2019 to 2025. Most recent: inspection, 4 December 2025.

Built
2019
Last inspected
4 December 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 December 2025
…with no type recorded1
…past their stated due date2
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2019–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1543199
Flag
UNITED STATES
Maury page id
psix-1543199

Documentation record

Tonnage as PSIX records it2 - Simplified, Net Ton
3 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 11

4 December 2025 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8277607
20 February 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8082124
1 March 2024 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7872866
29 January 2024 Drydock Exam · Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7857061
8 March 2023 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7647632
29 August 2022 Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7548218
28 August 2022 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7549636
13 January 2022 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7379785
3 March 2021 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7150526
8 January 2020 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6885417
28 January 2019 Plan Review "T" Boat · Construction Oversight · Initial Certification
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6616174

Deficiency record · 21

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 December 2025 No resolution recorded
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. MI discovered 08 adult life jackets were unserviceable. Replace with approved type and quantitative. Vessel will be reduced to nine (09) passengers, total persons allowed eleven (11) until deficiency is cleared by a marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2025 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 9 December 2025 Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Current waterlight is not operating as design. Replace with in-kind equipment. Vessel is restricted to daytime operation until def is cleared by a marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2025
Resolved 15 December 2025
Resolution: Received video evidence of light working properly.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 9 December 2025 No resolution recorded
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Life ring buoy was missing sections of reflective tape. Replace with approved type.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2025 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 March 2025 Resolved
A vessel not required to have a power driven fire pump must have three 2 1/2 gallon buckets. Vessel only had one fire bucket when MI arrived. Corrected on the spot. 46 CFR 181.610 Code 10 c
Action required: 10 - Deficiency Rectified
Due 12 March 2025
Resolved 12 March 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 March 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 11 March 2024
Resolution: New COI issued.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 March 2023 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Aspirin expired. Replace expired aspirin.
Action required: 10 - Deficiency Rectified
Due 8 March 2023
Resolved 8 March 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 March 2023 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Location not marked. Mark location as appropriate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2023
Resolved 22 March 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 March 2023 Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. SSMCP not onboard, as required. Provide SSMCP.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2023
Resolved 22 March 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 August 2022 Resolved
Positive shutoff valves shall be installed where the bilge line penetrates the hull. Both the port and starboard valves were frozen and inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2022
Resolved 20 September 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 August 2022 Resolved
Bilge pumps shall be permanently mounted. The securing bracket / strainer for the bilge pumps were not secured.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2022
Resolved 20 September 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 August 2022 Resolved
Shutoff valves shall be installed to close off the flow of fuel. The fuel shutoff valve was secured open with a zip tie.
Action required: 60 - Rectify deficiencies prior to movement
Due 30 September 2022
Resolved 20 September 2022
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 31 August 2022 Resolved
The construction and arrangement of the vessel must allow for safe operation in accordance with the COI. The port side shell is fractured in way of the forward bracket. the port and starboard gunwale caps are fractured in way of the gunwale.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 September 2022
Resolved 20 September 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 August 2022 Resolved
A ring life ring buoy with a water light shall operate and be properly secured. The water light was extinguished and the securing line was not adequate for service.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2022
Resolved 20 September 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 August 2022 Resolved
Each portable fire extinguisher shall be of an approved type. The securing bracket for the B:10 extinguisher was not the approved type.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2022
Resolved 20 September 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 August 2022 Resolved
Propulsion must be suitable for which it is installed. An oil line with improper fitting was dripping oil into the bilge.
Action required: 60 - Rectify deficiencies prior to movement
Due 30 September 2022
Resolved 20 September 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 August 2022 Resolved
Fuel lines shall be properly fitted and secured. The fuel fill closure device was broken and the fuel vent line was not double clamped.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2022
Resolved 20 September 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 March 2021 Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.050 in subchapter Q of this chapter. The life buoy was excessively weathered and requires replacement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 March 2021 Resolved
Each lifeline on a ring life buoy must be buoyant. Lifeline attached to ring life buoy not buoyant.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 March 2021 Resolved
Each vessel must be equipped with at least two operable portable battery lights. Flashlights on vessel inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2021
Resolved 7 April 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 March 2021 Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Multiple closures on the chain linked rail courses on port and starboard side frozen. Forward port side, missing link on closure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2021
Resolved 7 April 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 March 2021 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Life jacket placards not visible to passengers in current location.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2021
Resolved 7 April 2021