← All vessels
ENERGY GLORY
ENERGY GLORY is a 2019 tank ship. The Coast Guard has recorded 9 inspections since 2019, most recently in May 2024, along with 2 deficiencies.
Records from 2019 to 2024. Most recent: inspection, 19 May 2024.
- Built
- 2019
- Last inspected
- 19 May 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 2 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9752565 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
7JZD
1543649
Flag
JAPAN
—
Maury page id
psix-1543649
Inspections, by type
The 9 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it121981 - Convention (Subpart B), Gross Ton
88677 - Dead Weight, Ton
126979 - Displacement, Ton
36594 - Convention (Subpart B), Net Ton
88677 - Dead Weight, Ton
126979 - Displacement, Ton
36594 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 9
19 May 2024
PSC B · COC-GAS Renew
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7914853
8 July 2023
PSC B · COC-GAS Annual
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7734804
8 July 2022
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7500846
20 June 2022
PSC B · COC-GAS Renew
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7481612
17 December 2020
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7115477
2 July 2020
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6993482
12 June 2020
COC-GAS Annual · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6974525
3 April 2020
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6935109
10 June 2019
COC-GAS Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6709176
Deficiency record · 2
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 20 June 2022
Resolved
The machinery and associated pipes systems and fittings shall be adequate for the service which they are intended and shall be installed as to reduce to a minimum any dangers to persons on board. PSCO observed active leaking on #1 low duty compressor in the machinery room.
SOLAS (2020) II-1/26.1
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 June 2020
Resolved
07103 - The maximum pressure at any hydrant shall not exceed that at which effective control of a fire hose can be demonstrated. Upon activation of the STBD bridge wing fire hose, after receiving pressure from the emergency fire pump, the nozzle was not capable of being effectively controlled, and the internal gaskets at the nozzle and the manifold were blown causing them to protrude from their place. 74SOLAS(14)II-2/10.2.1.6.3
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.