CIUDAD DE CADIZ is a 2009 freight ship. The Coast Guard has recorded 8 inspections since 2019, most recently in June 2026, along with 2 deficiencies and 1 operational control.
Records from 2019 to 2026. Most recent: inspection, 23 June 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it15643 - Convention (Subpart B), Gross Ton 4692 - Convention (Subpart B), Net Ton 3533 - Dead Weight, Metric Ton 3533 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 8
23 June 2026Deficiency Check · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8407609
19 January 2026Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8298288
1 March 2023In-Service Inspection · Administrative Inspection · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7641851
25 February 2023Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7641878
3 January 2021PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7117448
18 December 2019Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6876252
3 May 2019Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6670379
26 April 2019Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6670828
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 June 2026Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from a storage tank having a capacity of 500l and above, shall be fitted with a cock or valve capable of being closed from a safe position outside the space concerned. PSCO observed quick closing valve labeled “ED006-FM” in emergency gen space inop.
74 SOLAS (09) II-2/4.2.2.3.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2026
Resolution: Reviewed BV survey report attesting to repair and operation of the quick closing valves (QCV). PSCO observed satisfactory operation of QCVs.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 June 2026Resolved
Fire protection systems shall be kept in good working order so as to ensure their required performance if fire occurs. PSCO observed inoperational test of quick closing valve on emergency gen and incinerator.
74 SOLAS (09) II-2/14.2.1.1
Action required: 705 - Other - as specified
Resolved 23 June 2026
Resolution: Prior to completion of exam, vessels crew conducted repairs of QCVs and PSCO observed satisfactory operation.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.