MAURY USCG vessel records
← All vessels

HURON RIVER MONSTER

HURON RIVER MONSTER is a 2019 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2019, most recently in May 2026, along with 19 deficiencies.

Records from 2019 to 2026. Most recent: inspection, 20 May 2026.

Built
2019
Last inspected
20 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 May 2026
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2019–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1544611
Flag
UNITED STATES
Maury page id
psix-1544611

Documentation record

Tonnage as PSIX records it2 - Regulatory (Subpart C or D), Gross Ton
2 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 14

20 May 2026 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8377004
13 May 2026 Vessel Attendance · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8371661
22 July 2025 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8191908
28 April 2025 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8212819
15 April 2025 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8106364
12 April 2024 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7894075
29 August 2023 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7771285
30 May 2023 Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7683642
20 July 2022 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7509738
20 May 2021 Deficiency Check · Annual Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7201891
16 October 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7078448
24 September 2019 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6819485
8 May 2019 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6679610
24 April 2019 Deadweight Survey · Initial Certification · Construction Oversight
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6656795

Deficiency record · 19

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 May 2026 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests:(1) Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Annual inspections need to be completed on extinguishers. 46 CFR 176.810 (b)(1)(i)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2026
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 May 2026 Resolved
(a) A vessel of 12 meters or more in length shall be provided with a whistle. (b) A vessel of less than 12 meters in length shall not be obliged to carry the sound signaling appliances prescribed in paragraph (a) of this Rule but if she does not, she shall be provided with some other means of making an efficient sound signal. Horn inoperable. 33 CFR 83.33 (a)(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 20 May 2026
Resolution: New horn.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 May 2026 Resolved
A power-driven vessel of less than 12 meters in length may, in lieu of the lights prescribed in paragraph (a) of this Rule, exhibit an all-round white light and sidelights. Vessels all around white light inoperable. 33 CFR 83.23 (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 20 May 2026
Resolution: New light
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 13 May 2026 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). A second power pump is an acceptable alternative to a hand pump if it is supplied by a source of power independent of the first power bilge pump. Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. Less than 7.9 m (26 ft)1 portable hand pump. Vessel missing portable hand pump. 46 CFR 182.520(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 20 May 2026
Resolution: New pump.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 May 2026 Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Vessel missing placard. 46 CFR 184.506
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 20 May 2026
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2026 Resolved
Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Monthly F/E inspections not logged. 46 CFR 176.810 (b)(ii)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 20 May 2026
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 13 May 2026 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:1) Date of the drill and training; and(2) General description of the drill scenario and training topics. Vessel not logging drills. 46 CFR 185.520 (f)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 May 2026
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 13 May 2026 Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:(1) Date of the drill and training; and(2) General description of the drill scenario and training topics. Vessel not logging drills. 46 CFR 185.524(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 20 May 2026
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 29 August 2023 Resolved
Each vessel must be equipped wiht at least 2 operable portable battery lights. Vessel did not have any portable lights onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2023
Resolved 7 September 2023
Resolution: Operator purchased new portable battery powered lights for vessel.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 August 2023 Resolved
The lights required to be carried shall be exhibited from sunrise to sunset in restricted visibility and may be exhibited in in all other circumstances when deemed necessary. Vessel's navigation lights were inoperable at the time of inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2023
Resolved 7 September 2023
Resolution: Operator repaired the faulty navigational light circuit and lights are now working.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 August 2023 Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 2.5 gallon buckets for the purpose of fire-fighting with an attached lanyard satisfacory to the cognizant [name withheld] fire buckets had lines as handles but not the required lanyards meeting this requirment. Attach lamyards to the fire buckets to the satisfactory of attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2023
Resolved 7 September 2023
Resolution: Operator installed lanyards on the vessel's fire buckets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 May 2021 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters(1 inch)high indicating purpose of the valve and direction of operation. There were no clear mark for the fuel shutoff valve. 46CFR185.608 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 June 2021
Resolution: Confirmed the installation of the sign.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 May 2021 Resolved
Each flare carried to meet this section must be stowed in a portable watertight container marked as required by 185.614 of this chapter, carried at the operating station. Flares were not located in a watertight container. 46CFR180.68(e)(1) 16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 June 2021
Resolution: Vessel has the container including markings.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 16 October 2020 Resolved
A vessel must comply with the applicable requirements for any radio installation as set forth by the Federal Communications Commission (FCC) in 47 CFR 80. The functionality of the vessel's radio could not be demonstrated. Vessel is restricted from operating beyond 1000 ft from shore.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 28 October 2020
Resolution: Operator submitted a video of a successful operational test of the radio.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 16 October 2020 Resolved
Portable fire extinguishers must be inspected and maintained in accordance with NFPA 10. Fire extinguishers are missing inspection tags and no report of annual inspection was found.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 28 October 2020
Resolution: Operator submitted photos of annual service tags for all fire extinguishers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 October 2020 Resolved
Each life jacket must be marked with the vessel's name in clearly legible block capital letters. No markings were observed on life jackets.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 28 October 2020
Resolution: Operator submitted photos of the vessel's name on lifejackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 October 2020 Resolved
Remote fuel shutoff valves must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve. Fuel shutoff valve was not marked. **Def. extended until May 2021 when operator will return to service for the season.**
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 20 May 2021
Resolution: Observed the markings.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 October 2020 Resolved
Ring life buoy must be marked with the vessel's name in block letters and marked with Type II retroreflective material. The letters and retro tape are peeling off.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 28 October 2020
Resolution: Operator submitted photo of life buoy with new markings for name and retroreflective material.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 April 2019 Resolved
Vessel's new owner will be required to complete a "new-to-zone" inspection once the vessel is delivered to its new OCMI zone. The attached CG-835, and the associated worklist, will need to be completed to the satisfaction of the attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2019
Resolved 31 May 2019
Resolution: Completed satisfactory COI inspection.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.