MAURY USCG vessel records
← All vessels

DAKOTA

DAKOTA is a 1977 passenger vessel (inspected). The Coast Guard has recorded 10 inspections since 2016, most recently in November 2023, along with 6 deficiencies.

Records from 2016 to 2023. Most recent: inspection, 28 November 2023.

Built
1977
Last inspected
28 November 2023
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDH2332
154488
Flag
UNITED STATES
Maury page id
psix-154488

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 8 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)44.8 ft × 14.0 ft × 6.2 ft
Registered tonnagegross 26 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX HULL · LOREAUVILLE LA, UNITED STATES · built 1977
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portRIVIERA, TX
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 10

28 November 2023 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7830548
2 March 2022 Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7401647
25 January 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7373929
30 December 2021 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7373906
30 November 2020 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7103507
29 October 2019 Drydock Exam · DAPI Audit · Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6844903
13 February 2019 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6625841
10 January 2018 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6338298
7 November 2017 Hull Examination · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6302426
8 November 2016 Internal Structural Exam · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6037126

Deficiency record · 6

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 March 2022 Resolved
Retroreflective tape on Ring buoys was worn and no longer retroreflective.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2022
Resolved 9 March 2022
Resolution: Received photo documentation of proper installation of the solas retroreflective tape
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 December 2021 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel has not received a drydock exam in over 2 years. Vessel must receive credit drydock examination prior to departure from pier. 46 cfr 176.600 (c)(1) 17, c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2022
Resolution: Vessel received a satisfactory drydock exam.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 10 January 2018 Resolved
Vessel must have at least one person on watch with a valid marine radio operator permit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 29 January 2018
Resolution: Master recieved marine radio operator permit
Navigation › Piloting/Steering › Marine Charts
Issued 10 January 2018 Resolved
Vessel needs currently corrected charts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 29 January 2018
Resolution: Vessel obtained current charts
Operations/Management › Drills/Instruction › Safety Orientation
Issued 10 January 2018 Resolved
Vessel must provide training to all deckhands regarding vessel safety and log the training.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 January 2018
Resolution: Vessel provided and logged appropriate training
Documentation › Logs/Records › Drug Test Records
Issued 10 January 2018 Resolved
Provide proof of enrollment in a DOT accepted chemical testing program to include pre-employment testing.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 January 2018

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.