DAKOTA is a 1977 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2005, most recently in November 2023, along with 22 deficiencies and 1 operational control.

Records from 2005 to 2023. Most recent: inspection, 28 November 2023.

Built
1977
Last inspected
28 November 2023
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH2332
154488
Flag
UNITED STATES
367596540 (licence lapsed)
Maury page id
psix-154488

Inspections, by type

…with no type recorded1
Years with a record 15 calendar years (2005–2023)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)44.8 ft × 14.0 ft × 6.2 ft
Registered tonnagegross 26 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX HULL · LOREAUVILLE LA, UNITED STATES · built 1977
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portRIVIERA, TX
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH2332MMSI 367596540 · expired · voluntarily equipped · granted 23 November 2013, cancelled 27 January 2024
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 23

28 November 2023 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7830548
2 March 2022 Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7401647
25 January 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7373929
30 December 2021 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7373906
30 November 2020 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7103507
29 October 2019 Drydock Exam · DAPI Audit · Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6844903
13 February 2019 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6625841
10 January 2018 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6338298
7 November 2017 Hull Examination · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6302426
8 November 2016 Internal Structural Exam · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6037126
10 December 2015 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5778673
4 November 2015 Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5757204
5 January 2012 Internal Structural Exam · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4212885
18 January 2011 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3930381
5 January 2011 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3920990
25 October 2010 Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3877382
21 December 2009 COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3650033
9 December 2008 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3376489
25 November 2008 Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3369004
15 February 2008 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3148178
12 February 2008 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3145437
12 December 2005 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2550227
7 January 2005 COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2276595

Deficiency record · 22

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 March 2022 Resolved
Retroreflective tape on Ring buoys was worn and no longer retroreflective.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2022
Resolved 9 March 2022
Resolution: Received photo documentation of proper installation of the solas retroreflective tape
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 December 2021 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel has not received a drydock exam in over 2 years. Vessel must receive credit drydock examination prior to departure from pier. 46 cfr 176.600 (c)(1) 17, c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2022
Resolution: Vessel received a satisfactory drydock exam.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 10 January 2018 Resolved
Vessel must have at least one person on watch with a valid marine radio operator permit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 29 January 2018
Resolution: Master recieved marine radio operator permit
Navigation › Piloting/Steering › Marine Charts
Issued 10 January 2018 Resolved
Vessel needs currently corrected charts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 29 January 2018
Resolution: Vessel obtained current charts
Operations/Management › Drills/Instruction › Safety Orientation
Issued 10 January 2018 Resolved
Vessel must provide training to all deckhands regarding vessel safety and log the training.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 January 2018
Resolution: Vessel provided and logged appropriate training
Documentation › Logs/Records › Drug Test Records
Issued 10 January 2018 Resolved
Provide proof of enrollment in a DOT accepted chemical testing program to include pre-employment testing.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 January 2018
Lifesaving › Lifefloat › Serviceable
Issued 10 December 2015 Resolved
Plug missing on six man life float. Replace plug with manufacture approved part. Vessel is reduced to 24 total persons on a limited coastwise route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 December 2015
Resolved 16 December 2015
Resolution: Replaced plug in accordance with manufactures specifications.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 January 2011 Resolved
Replace expired contents of required First Aid Kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 February 2011
Resolved 18 January 2011
Resolution: Ammonia inhalents were purchased and placed in First aid kit.
Engineering › Fuel Oil Service System › Valve
Issued 5 January 2011 Resolved
Properly label the remote fuel shutoff valves located on the main deck both port and starboard side for easy identification.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 February 2011
Resolved 18 January 2011
Resolution: Remote Fuel shutoff valves were properly labeled. Pictures attached to activity.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 5 January 2011 Resolved
Install locking device for marine sanitation device overboard valve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 February 2011
Resolved 18 January 2011
Resolution: Lock was installed and valve closed.
Engineering › Lubricating Oil Service System › Hose
Issued 21 December 2009 Resolved
Replace lube oil hose (the one with rubber visible) on STBD engine
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2010
Resolved 22 December 2009
Resolution: Owner/operator replaced lube oil hose on starboard propulsion engine.
Engineering › Lubricating Oil Service System › Hose
Issued 21 December 2009 Resolved
Place chafing guard on lube oil hose on STBD engine
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 January 2010
Resolved 22 December 2009
Resolution: Owner/operator installed a new chaffing guard on the lube oil hose on the starboard propulsion engine.
Construction/Loadline › Hull › Hull Plating
Issued 21 December 2009 Resolved
Weld seam underneath port side exhaust in lazarette.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 January 2010
Resolved 22 December 2009
Resolution: Owner/operator welded the underside of the port side exhaust where it exits the stern of the vessel.
Lifesaving › Liferaft Equipment › Paddle
Issued 21 December 2009 Resolved
Stencil vessel's name on paddle for six man life float.
Action required: 705 - Other - as specified
Due 21 January 2010
Resolved 21 December 2009
Resolution: Corrected on the spot
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 8 December 2008 Resolved
Two lifejacket lights were inoperable. Replace batteries.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2008
Resolution: Batteries were replaced and the lights functioned properly.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 8 December 2008 Resolved
The retroreflective material of a PFD was not securely fastened. Replace PFD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2008
Resolution: PFD was replaced with fastened retroreflective material.
Stability › Weathertight Integrity › General
Issued 8 December 2008 Resolved
A cable penetration on the aft part of the wheelhouse was not stuffed properly, exposing the wheelhouse to the weather. Stuff cable penetration to make space weathertight.
Action required: 705 - Other - as specified
Resolved 9 December 2008
Resolution: The cable penetration was stuffed and is properly sealed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 December 2008 Resolved
Two eyewash packets in the first aid kit were expired. Replace eyewash packets.
Action required: 705 - Other - as specified
Resolved 9 December 2008
Resolution: Two eyewash packets were replaced for the first aid kit.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 December 2008 Resolved
A 1/2" fracture on the aft bulkhead in the lazarette, stbd. side, was found. Fracture is required to be repaired.
Action required: 705 - Other - as specified
Resolved 9 December 2008
Resolution: Fracture was ground out. Due to the fracture being shallow, the grinding was sufficient to fix the fracture.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 December 2005 Resolved
Mount wires in pasenger void stbd side.
Action required: 705 - Other - as specified
Due 15 January 2006
Resolved 16 December 2005
Resolution: Wiring mounted.
Engineering › Bilge Water Management System › Pump
Issued 15 December 2005 Resolved
Repair or replace bilge pump in lazarette.
Action required: 705 - Other - as specified
Due 15 January 2006
Resolved 16 December 2005
Resolution: Bilge pump replaced
Engineering › Bilge Water Management System › Hose
Issued 15 December 2005 Resolved
Replace bilge pump hose near discharge of lazarette.
Action required: 705 - Other - as specified
Due 15 January 2006
Resolved 16 December 2005
Resolution: Hose replaced.

Ownership record