ASTERAS is a 2013 freight ship. The Coast Guard has recorded 14 inspections since 2019, most recently in February 2026, along with 10 deficiencies — 2 with no resolution recorded — and 3 operational controls.
Records from 2019 to 2026. Most recent: operational control imposed, 25 February 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it33456 - Convention (Subpart B), Gross Ton 19326 - Convention (Subpart B), Net Ton 56605 - Dead Weight, Metric Ton 67932 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 14
25 February 2026Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8316583
25 February 2026Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8316609
24 February 2026Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8315233
2 February 2026Administrative Inspection · Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8305078
31 January 2026PSC A
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8303521
28 January 2026Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8308548
29 April 2024Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7903156
26 April 2024PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7897415
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 4 February 2026No resolution recorded
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Due to a fire on the stern launch lifeboat, class issued an interim cert. allowing the vessel a single voyage from Portland, ME to New Orleans, LA for a new free fall lifeboat to be installed by 13 FEB 2026.
74SOLAS24 III/20.2
17ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2026 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 4 February 2026No resolution recorded
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Due to a fire on the stern launch lifeboat and launching appliance, class issued an interim cert. allowing the vessel a single voyage from Portland, ME to New Orleans, LA for repairs/replacement of launching appliance by 13 FEB 2026.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2026 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 February 2026Resolved
Firefighting systems and applicances shall be kept in good working order and ready for immediate use. While conducting a deficiency check, PSCO observed leaks in Fire Main. Captain stated it was due to freezing of pipes.
74SOLAS20, II-2, 14.2.1.2
17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2026
Resolution: Received class report attesting to repairs to fire main.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 31 January 2026Resolved
Fire-fighting systems and appliacnes shall be kept in good working order and readily available for immediate use. PSCO observed lack of fire-fighting water forward of the house.
74SOLAS24 II-2/14.2.1.2
17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2026
Resolution: Received class report attesting to operation of fire main.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 31 January 2026Resolved
Each lifeboat shall be provided with an appliance which is capable of launching and recovering the lifeboat. Due to fire, PSCO was unable to verify proper operation of the launching arrangements for freefall lifeboat.
74SOLAS24 III/16.2
17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2026
Resolution: Received class interim cert allowing vessel to transit to NOLA for repairs. Will reissue def requiring repairs in 14 days.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 April 2024Resolved
Eletrical installations shall be such that the safety of passengers, crew and ship from eletrical hazards will be ensured. PSCO observed live wire on deck in the eletrical workshop.
74 SOLAS 20 II-1/40.1.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 April 2024
Resolved 26 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 2 August 2021Resolved
Before the ship leaves port and at all times during the voyage, all life-saving applicances shall be in working order and ready for immediate use. Took 45 minutes for crew to start rescue boat engine. 74 SOLAS (2014) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 August 2021
Resolution: Crew was eventually able to start rescue boat engine during exam.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 2 August 2021Resolved
Fire extinguishing appliances shall be readily available. Took 20 minutes for crew to start emergency fire pump. 74 SOLAS (2014) II-2/10.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 August 2021
Resolution: Crew eventually were able to start emergency fire pump with two efficient water streams.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 August 2021Resolved
The purpose of this regulation is to provide means of escape so that persons onboard can safely and swiftly escape to the lifeboat and liferaft embarkation deck. Two wing nuts on the escape leading out from the forecastle deck were painted over. Crew could not escape. 74 SOLAS (2014) II-2/13.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 2 August 2021
Resolution: Crew got wing nuts unstuck so crew able to open and escape.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 March 2019Resolved
The fire resistance of doors shall be equivalent to that of the division in which they are fitted, this being determined IAW the fire test procedures code. Doors fitted in boundary bulkheads of machinery spaces of category 'A' shall be reasonably gas tight and self-closing. 'A-60' door to Engine Room from upper deck is not capable of closing via self-closing device nor does the door latch properly. Captain notified the company of the issue in December. Technicians were on board to repair the door, but were unsuccessful. They recommended the door be replaced, but a new door has not been ordered by company. Cite: 74 SOLAS 2014 Consolidated 11-2/9.4.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2019
Resolution: Vessel submitted a satisfactory class report attesting to the temporary repair of the current door and ordering of a new door.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.