MAURY USCG vessel records
← All vessels

UNIVERSAL LEADER

UNIVERSAL LEADER is a tank ship. The Coast Guard has recorded 1 inspection in 2026, along with 1 deficiency.

Records in 2026. Most recent: inspection, 10 May 2026.

Built
Not recorded
Last inspected
10 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 May 2026
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9837597
1545182
Flag
PANAMA
Maury page id
psix-1545182

Documentation record

Tonnage as PSIX records it156331 - Convention (Subpart B), Gross Ton
299981 - Dead Weight, Metric Ton
343726 - Displacement, Metric Ton
106852 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 1

10 May 2026 PSC A · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8355417

Deficiency record · 1

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 10 May 2026 Resolved
The gas detection equipment shall be so designed that it may readily be tested. PSCO observed equipment was unable to be tested for LEL. Master provided tisk mitigation plan. SOLAS (22) II-2/4.5.7.3.1 FSS Code 15.2.2.3.4
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2026
Resolved 19 June 2026
Resolution: Received a class report/proper documentation satisfying the requirement

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.