NAVIGATOR VEGA is a 2019 tank ship. The Coast Guard has recorded 7 inspections since 2020, most recently in October 2025, along with 4 deficiencies and 1 operational control.
Records from 2020 to 2025. Most recent: operational control imposed, 6 October 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it19205 - Convention (Subpart B), Gross Ton 19205 - Regulatory (Subpart C or D), Gross Ton 24553 - Dead Weight, Ton 34242 - Displacement, Ton 5762 - Convention (Subpart B), Net Ton 5762 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 7
6 October 2025Deficiency Check · COC-GAS Renew · PSC A
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8245479
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 6 October 2025Resolved
In meeting these requirements, the Company should ensure that:
.1 inspections are held at appropriate intervals
.2 any non-conformity is reported, with its possible cause, if known
.3 appropriate corrective action is taken
The technical and operational nature of the deficiencies noted below (#2-4) provide objective evidence of a serious failure of the implementation of the ISM Code. An external audit report satisfactory to OCMI must be submitted prior to clearance of this deficiency.
74 SOLAS (20) IX/3.1
ISM Code 10.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 9 October 2025
Resolved 9 October 2025
Resolution: ISM deficiency corrected via DNV shipboard audit report.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 October 2025Resolved
A permanently installed system of gas detection and audible and visual alarms should be provided for:
.1 Cargo Pump room;
.2 cargo compressor rooms;
.3 motor rooms for cargo handling machinery;
.4 cargo control rooms unless designated gas safe;
.5 other enclosed spaces in the cargo area where vapor may accumulate including hold and inter barrier spaces for independent tanks other than type C tanks.
PSCO observed inoperable fixed gas detection system. When supplied with 50% LEL propane gas, system failed to read above 0% LEL. PSCO observed repeated flow fault alarms due to analyzing pump failures. Analyzing pump cooling fan was inoperable and pump was extremely hot to the touch. Additionally when running pump vibrates excessively.
74 SOLAS (20) VIII/13.1
IGC (93) 13.6.7
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 9 October 2025
Resolved 9 October 2025
Resolution: Resolved via uploaded tech report and local tests of system.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 October 2025Resolved
Electrical equipment, cables, and wiring should not be installed in hazardous locations unless it conforms with the standards not inferior to those acceptable to the organization.
PSCO observed both exhaust fans for the cargo compressor room ventilation with exposed wiring and improperly installed wire packing glands. Additionally, 03 light installations near the manifolds were found with exposed wiring and improper wire splices covered with electrical tape.
74 SOLAS (20) VIII/13.1
IGC (93) 10.1.4
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 9 October 2025
Resolved 9 October 2025
Resolution: Resolved via certificate of conformity and ensuring proper installation.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 October 2025Resolved
On ships carrying flammable or toxic products or both, a water spray system for cooling, fire prevention, and crew protection should be installed on:
.1 cargo tank domes and exposed parts of cargo tanks
PSCO observed insufficient pressure to cover tank domes 1 port and starboard, and 3 port.
74 SOLAS (20) VIII/13.1
IGC 11.3.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 9 October 2025
Resolved 9 October 2025
Resolution: Resolved via test of deck water spray. Ensured conforamance with standard.