MAURY USCG vessel records
← All vessels

ENCORE I

ENCORE I is a 2019 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2018, most recently in April 2026, along with 4 deficiencies and 1 casualty investigation in 2019.

Records from 2018 to 2026. Most recent: inspection, 28 April 2026.

Built
2019
Last inspected
28 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 April 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2018–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK6983
1546547
Flag
UNITED STATES
Maury page id
psix-1546547

Documentation record

Registered dimensions (L × B × D)40.0 ft × 12.0 ft × 6.5 ft
Registered tonnagegross 20 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBOSTON BOAT WORKS · CHARLESTOWN, MA, UNITED STATES · built 2019
Hull materialFRP (Fiberglass)
PropulsionDiesel Electric
Hull shapeShip
Hull configurationMonohull
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

16 inspections, each with its date, unit and type; 4 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

28 April 2026 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8357701
24 April 2025 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8099781
4 February 2025 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8051822
25 April 2024 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7882779
16 May 2023 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7672872
22 February 2023 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7637140
31 October 2022 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7587278
10 May 2022 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7428939
6 May 2022 Construction Oversight
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7428984
23 June 2021 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7233707
23 March 2021 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7161304
18 August 2020 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7036179
13 November 2019 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6854755
1 November 2019 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6847450
1 November 2019 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6890503
11 October 2018 COI Inspection · Construction Oversight · Hull Examination · Simplified Stability Test · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6691501

Deficiency record · 4

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 April 2025 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by table 1 to § 181.500(b) and other provisions of this section. The required 40-B:C fire extinguishers for the machinery space exits were not present. Replaced current portable extinguishers installed at machinery space exits with 40-B:C extinguishers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2025
Resolved 2 May 2025
Resolution: New portable fire extinguishers purchased and placed on board.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 November 2019 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Vessel's reverse cycle heating system was overheating, producing smoke at the heat pump. Rectify prior to operating reverse cycle heating system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2019
Resolved 30 June 2020
Resolution: Installed new system with correct overcurrent protection. Reviwed new approved drawing, inspected installation, tested sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2019 Resolved
Each circuit must meet UL489. Circuit breakers are not UL489 approved.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2019
Resolved 6 September 2019
Resolution: Operator installed UL 489 approved circuit breakers for all circuits.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 13 June 2019 Resolved
A space containing diesel machinery must be fitted with at least two ducts to furnish natural or powered supply and exhaust ventilation. The total inlet area and total outlet area may not be less than one square inch for each foot of beam of the vessel. There is only one ventilation opening into the space that serves as supply. Provide a separate duct for exhaust ventilation. Operator must ensure space is adequately ventilated prior to starting generator.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2019
Resolved 6 September 2019
Resolution: Operator installed a second ventilation duct in the engine room space for exhaust ventilation

Casualty record · 1

1 November 2019Routine · role: Involved in a Marine Casualty · activity 6890503
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.