ECO MARINA DEL REY
ECO MARINA DEL REY is a 2015 tank ship. The Coast Guard has recorded 10 inspections since 2019, most recently in May 2026, along with 2 deficiencies.
Records from 2019 to 2026. Most recent: inspection, 30 May 2026.
- Built
- 2015
- Last inspected
- 30 May 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 2 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9798349 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7A2018
1546884
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1546884
Inspections, by type
The 10 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it29994 - Convention (Subpart B), Gross Ton
13850 - Convention (Subpart B), Net Ton
50267 - Dead Weight, Metric Ton
60774 - Displacement, Metric Ton
13850 - Convention (Subpart B), Net Ton
50267 - Dead Weight, Metric Ton
60774 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 10
30 May 2026
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8384295
1 May 2026
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8358129
30 July 2024
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7970633
21 July 2024
COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7963173
15 November 2023
PSC B · MARPOL Annex I Examination · Ballast Water Examination · ISPS Exam · COC-CHEM Renew
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7819899
19 August 2022
PSC B · COC-CHEM & TVE Annual
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7528164
29 July 2021
COC-CHEM Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7271570
30 July 2020
COC-CHEM & TVE Annual · ISPS Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7014133
14 December 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6873891
26 May 2019
COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6685521
Deficiency record · 2
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 August 2022
Resolved
01-07199-The fixed gas sampling shall be designed to sample and analyze from each sampling line of each protected space, sequentially at intervals not exceeding 30 min. All WBT and FPT were observed being skipped and not sampling. SOLAS 20 CONS Chp II-2 FSS Chp. 16.2.2.3.1 - 10C
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 19 August 2022
Resolved
02-07102-The inert gas system shall be designed to be capable of rendering and maintaining the atmosphere of the relevant cargo tanks non-flammable. The port and starboard slop tanks and #6 starboard cargo tank had a O2 content of 9.7%. SOLAS 20 Cons Chp. II-2 FSS Chp.14.2.2.1.2.1 - 10C
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.