Records from 1995 to 2026. Most recent: inspection, 5 June 2026.
Inspection history · 25
5 June 2026
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8395909
22 May 2025
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8141349
21 March 2025
Administrative Inspection · Drydock Exam · Examination of Repairs · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8097710
9 September 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7999892
30 November 2023
Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7855494
6 July 2023
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7734524
10 June 2022
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7473751
6 December 2021
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7363866
6 April 2020
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6940424
30 November 2015
Industry Initiated Exam
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5773141
9 April 2015
Marine Casualty Follow Up · Damage Survey
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5102671
9 April 2015
Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5102682
28 March 2013
DAPI Audit
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4557984
30 August 2012
Administration
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4426373
1 December 2011
Industry Initiated Exam · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4210965
12 April 2010
Industry Initiated Exam
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3715888
28 December 2009
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3669326
22 July 2002
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1673092
19 November 1999
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 435223
15 November 1999
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 435209
9 November 1998
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 422464
10 August 1997
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 409372
28 July 1997
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 408058
16 June 1995
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 753623
15 June 1995
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 205286
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2026
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. During shut down of port engine, engine would not respond to ignition switch and could only be secured by remote fuel shut off. 46 CFR 143.205(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2026
Resolved 24 June 2026
Resolution: Replaced solenoid.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 June 2026
Resolved
Stations in the maritime service must be licensed by the FCC either individually or by fleet. FCC Station license on board expired in March 2026. 47 CFR 80.13(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2026
Resolved 24 June 2026
Resolution: Obtained new FCC SSL
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 5 June 2026
Resolved
Each exhaust pipe from an internal combustion engine which is within reach of personnel must be insulated or otherwise guarded to prevent burns. Port generator exhaust has unguarded elbow missing lagging. 46 CFR 144.830
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2026
Resolved 24 June 2026
Resolution: Replaced lagging
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 June 2026
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. 24v battery charger chassis are not grounded IAW manufacturers installation requirements. 46 CFR 143.205(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2026
Resolved 27 July 2026
Resolution: battery charging box is properly ground to the box and to proper grounding block.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2025
Resolved
Each life jacket must have a life jacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the life jacket.
Several attached life jacket lights beyond the expiration date. Renew expired life jacket lights.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 16 June 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 June 2025
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Galley breaker panel missing blank cover, install cover in way of breaker opening to minimize shock hazards.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 16 June 2025
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 10 June 2025
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. Vessels COD had been renewed but current version not yet placed on board. Place current version on COD on board vessel.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 11 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 September 2024
Resolved
VESSEL MUST CARRY HAND-HELD RED DISTRESS SIGNALS, DISTRESS SIGNALS WERE EXPIRED
Action required: 705 - Other - as specified
Due 2 October 2024
Resolved 18 September 2024
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 September 2024
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Fire extinguisers were not marked with monthly inspections. No record was provied that the inspections had been completed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2024
Resolved 18 September 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 September 2024
Resolved
Vessel must have operational navigation lights. Vessels starboard navigation light was not operational.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 October 2024
Resolved 18 September 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 July 2023
Resolved
Each lifejacket must be marked; With Type I retro-reflective material approved under approval series 164.018. The arrangement of the retro-reflective material must meet IMO Resolution A.658(16) (incorporated by reference, see 136.112 of this subchapter). 04 lifejackets on second deck missing retro-reflective material.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2023
Resolved 14 July 2023
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 July 2023
Resolved
Inspection and testing. All portable fire extinguishers, semi-portable fire-extinguishing systems, fire-detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months; All smoke- and fire-detection systems, including detectors and alarms, must be tested. Provide
report of inspection/ testing for installed fire-detection system to include engine room alarms and detectors.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2023
Resolved 14 July 2023
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 6 July 2023
Resolved
Each towing vessel must perform the applicable tests in
Table 143.245(b) of this section. Alarm set points
Twice every 5 years, with no more than 3 years elapsing. Vessel had not completed nor had the means on board to test the required machinery alarm set points. Provide proof of testing and proper operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2023
Resolved 17 July 2023
Resolution: Attended vessel, witnessed alarm setpoints intermediate testing, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2023
Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with one or more spring-loaded relief valves. Relief valves must be tested in accordance with 143.245; Twice every 5 years, with no more than 3 years elapsing since last test. Provide proof of testing or replacement of on-board pressure vessel, pressure relief valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2023
Resolved 13 July 2023
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 10 June 2022
Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway to include items listed in 46CFR140.635. This list includes noting prevailing visibility, weather conditions, and anticipated changes along the intended route. Vessel does not adequately capture those required items in navigation assessment / TVR.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2022
Resolved 17 June 2022
Resolution: Navigation assessment updated.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 19 June 2020
Resolved
Replace watertight door gaskets on port & stbd engine room doors and stbd galley door.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2020
Resolved 26 June 2020
Resolution: Vessel rep sent sufficient photos of all gaskets replaced and properly installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 June 2020
Resolved
Install a B:II/ 40-B:C portable fire extinguisher for flammable storage locker.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2020
Resolved 26 June 2020
Resolution: Vessel rep sent sufficient photos of a BII/40:BC properly installed.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 19 June 2020
Resolved
Label both sides of watertight doors with 1 inch letters "WATERTIGHT DOOR- KEEP CLOSED"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2020
Resolved 26 June 2020
Resolution: Vessel rep sent sufficient photos of proper watertight door labels on doors.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 19 June 2020
Resolved
Label each emergency exit and escape hatch on both side with 2 inch letters "EMERCENY EXIT- KEEP CLEAR"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2020
Resolved 26 June 2020
Resolution: Vessel rep sent sufficient photos of proper emergency exit labels on doors.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 June 2020
Resolved
Repair or replace emergency lighting fixture in engine room at top of ladder.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2020
Resolved 19 June 2020
Resolution: Vessel provided objective evidence of repaired emergency light; picture of Master testing fixture.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 June 2020
Resolved
Secure and route exposed wires in fwd hold to junction box or remove.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2020
Resolved 19 June 2020
Resolution: Vessel rep provided pictures of exposed wires routed to electrical box.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 June 2020
Resolved
Label location of breaker for stove shut off at stove and in breaker box.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2020
Resolved 19 June 2020
Resolution: Vessel rep provided picture of adequate label.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 16 June 2020
Resolved
Reinstall insulation on hot piping on stbd MDE exhaust.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2020
Resolved 26 June 2020
Resolution: Vessel rep sent sufficient photos of lagging replaced and properly installed.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 6 April 2020
Resolved
Install fall protection on aft 02 deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2020
Resolved 26 June 2020
Resolution: Vessel rep sent sufficient photos of two rows of chains for fall protection.
Fire Fighting
Issued 15 November 1999
Resolved
Fire extinguishers must be properly mounted.
Condition: Unknown
Due 15 December 1999
Resolved 29 November 1999
Engineering
Issued 15 November 1999
Resolved
Flame screen on the stbd side must be replaced.
Condition: Unknown
Due 15 December 1999
Resolved 29 November 1999
Fire Fighting
Issued 28 July 1997
Resolved
VESSEL'S FIRE EXTINGUISHERS NEED TO BE SERVICED.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Navigation
Issued 28 July 1997
Resolved
VESSEL DIDN'T HAVE LOCAL NOTICE TO MARINERS, NAV RULES.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Navigation
Issued 28 July 1997
Resolved
VESSEL WAS MISSING STERN LIGHT.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Navigation
Issued 28 July 1997
Resolved
VESSEL WAS MISSING MAGNETIC COMPASS OR SWING METER.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Navigation
Issued 28 July 1997
Resolved
VESSEL WAS MISSING BELL.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997