MAURY USCG vessel records Sign in
← All vessels

HIBERNIAN TIDE

HIBERNIAN TIDE is a tank ship. The Coast Guard has recorded 7 inspections since 2019, most recently in May 2024, along with 1 deficiency and 1 operational control.

Records from 2019 to 2024. Most recent: inspection, 21 May 2024.

Built
Not recorded
Last inspected
21 May 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9800568 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1547342
Flag
LIBERIA
—
Maury page id
psix-1547342

Inspections, by type

…with no type recorded1
Years with a record 4 calendar years (2019–2024)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it33578 - Regulatory (Subpart C or D), Net Ton
109900 - Dead Weight, Ton
62508 - Convention (Subpart B), Gross Ton
62508 - Regulatory (Subpart C or D), Gross Ton
62508 - Displacement, Ton
33578 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 7

21 May 2024 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7916431
25 August 2023 PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7771601
24 August 2023 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7775787
24 August 2023 COE-Offshore
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7775789
10 June 2021 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7221438
26 January 2021 COC-TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7125196
13 May 2019 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6681211

Deficiency record · 1

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 25 August 2023 Resolved
Gas detection equipment in gastight cabinet is to be monitored by its own sampling point. At a gs concentration above 30% of the lower flammable limit inside the steel enclosure the entire gas analysing unit is to be automatically shut down. While conducting test of the fixed gas detection unit, PSCO observed internal sampling point unable to measure 30% of the lower flammable limit and did not shut down. SOLAS (20) II - 2 Reg 4.5.7.3.1 FSS Code CH 16.2.2.2.1.4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 May 2024
Resolution: Class survey received, fixed gas sampling system functioning within normal working parameters.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.