MAURY USCG vessel records Sign in
← All vessels

HELL BOUND

HELL BOUND is a 2019 passenger vessel (inspected). The Coast Guard has recorded 8 inspections since 2019, most recently in March 2026, along with 3 deficiencies.

Records from 2019 to 2026. Most recent: inspection, 5 March 2026.

Built
2019
Last inspected
5 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

1547369
Flag
UNITED STATES
—
Maury page id
psix-1547369

Inspections, by type

Years with a record 8 calendar years (2019–2026)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)39.9 ft × 12.3 ft × 4.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderKARLS WELDING · ASOTIN, WA, UNITED STATES · built 2019
Hull materialAluminum
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portLEWISTON, ID
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 8

5 March 2026 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8320652
27 March 2025 DAPI Audit · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8102808
20 March 2024 COI Inspection · Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7885363
27 April 2023 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7695925
15 March 2022 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7624279
24 February 2021 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7149561
19 February 2020 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6915967
1 January 2019 Construction Oversight · Simplified Stability Test · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6664624

Deficiency record · 3

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 February 2020 Resolved
Vessel is required to carry five child size life jackets as per COI. Only four could be produced. Vessel limited to the carriage of four children until a fifth child size lifejacket is placed into permanent service.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 March 2020
Resolved 17 March 2020
Resolution: Marine Inspector Witnessed 05 Child size lifejackets onboard the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 February 2020 Resolved
One of the child size lifejackets onboard the vessel was not marked IAW regulations. Vessel directed mark lifejackets IAW regulations.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 March 2020
Resolved 17 March 2020
Resolution: Attending Marine Inspector witnessed proper marking on all child size life jackets.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 February 2020 Resolved
Vessel could not produce 03 Fire Buckets as required by the regulations. Vessel directed to place into service 03 fire buckets.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 March 2020
Resolved 17 March 2020
Resolution: Marine Inspector witnessed 03 fire buckets placed into service.

Ownership record