04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 11 April 2019
Resolved
Each fire drill shall include:
-Reporting to stations and preparing for the duties described in the muster list.
-Checking the firemans outfit.
-Checking of relevant communication equipment.
PSCOs observed that during first fire drill crew did not conduct a muster in accordance with muster list and shipboard fire drill checklist. During drill no communications were conducted between bridge, on-scene coordinator, or fire team.
During second drill crew attempted to fight oil-based fire with water hose. Crew could not demonstrate knowledge on use of foam applicators to fight oil-based fire.
74 SOLAS (14) III/19.3.5.2
17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2019
Resolution: Observed satisfactory manifold fire drill. Crew demonstrated effective use of shipboard emergency procedures and checklist. Demonstrated effective communication throughout drill and proper knowledge of fire fighting procedures and equipment.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 April 2019
Resolved
The number of foam applicators provided shall be not less than four.
PSCOs observed that the vessel only had three foam applicators to fight a fire on the cargo deck.
74 SOLAS (04) II-2/10.8.1.1
17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2019
Resolution: Visually confirmed that 04 foam applicators were provided on board the vessel for use on the cargo deck. Confirmed that the newly delivered applicator was compatible with the vessel's fire hoses.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 11 April 2019
Resolved
The company should establish programmes for drills and exercises to prepare for emergency action.
PSCOs observed that crew failed to conduct drills in accordance with emergency procedures from New Shipping Limited's safety management system.
Company should determine root cause of failure and provide corrective action.
74 SOLAS (14) IX/3.1
ISM (18) Part A/8.2
50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2019
Resolved 22 April 2019
Resolution: Provided Corrective Action Report. See attached.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 11 April 2019
Resolved
General arrangement plans shall be permanently exhibited for the guidance of ship's officers showing clearly for each deck the fire extinguishing appliances.
Fire control plan did not indicate presence and location of deck foam applicators.
74 SOLAS (04) II-2/15.2.4.1
50ac
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2019
Resolved 22 July 2019
Resolution: Submitted Updated plan
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 11 April 2019
Resolved
Each abandon ship drill shall include reporting to stations and preparing for the duties described in the muster list.
PSCOs observed 02 SARTs were not provided at muster location as required by shipboard station bill.
74 SOLAS (14) III/19.3.4.1
10c
Action required: 10 - Deficiency Rectified
Resolved 11 April 2019
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 11 April 2019
Resolved
Personal equipment shall consist of protective clothing of material to protect skin from heat radiating from fire. The outer surface shall be water resistant.
PSCOs observed fire team member donning and fighting fire in drill with fire hood not in serviceable condition. Outer protective layer was peeling on hood.
74 SOLAS (04) II-2/10.10.1
FSS (07) 3.2.1.1
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 11 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 April 2019
Resolved
On cargo ships each lifejacket shall be fitted with a lifejacket light complying with the requirements of paragraph 2.2.3 of the Code.
Lifejacket light was observed to be expired and inoperable.
74 SOLAS (14) III/32.2.2
10c
Action required: 10 - Deficiency Rectified
Resolved 11 April 2019