Records from 2019 to 2025. Most recent: inspection, 8 December 2025.
Inspection history · 9
8 December 2025
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8278253
10 December 2024
COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8034601
11 January 2024
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7886845
10 January 2023
Annual Inspection · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7623331
11 March 2022
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7410321
4 January 2022
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7375587
5 January 2021
Internal Structural Exam · Drydock Exam · Annual Inspection · DAPI Audit · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7120260
7 January 2020
DAPI Audit · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6884914
23 April 2019
Simplified Stability Test · Initial Certification · DAPI Audit · Plan Review "T" Boat · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6669215
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 December 2025
Resolved
Fuel tank must meet standards of approval.
Tank top was deteriorated.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2025
Resolved 11 December 2025
Resolution: Tank was replaced with new one. Pictures provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 December 2025
Resolved
Each life jacket must be marked with Type I retroreflective material.
04 life jackets had worn retroreflective material requiring replacement. Restricted to 13 passengers until rectified.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2025
Resolved 11 December 2025
Resolution: 04 Life jackets were replaced with new ones. Pictures provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 December 2025
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material.
Ring Life buoy had damaged/missing retroreflective material.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2025
Resolved 11 December 2025
Resolution: Ring life buoy was renewed with vessel name and retroreflective material. Pictures provided.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 January 2022
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). Vessel's VHF radio installation was removed. Vessel restricted to operations within 1000 ft from shore.
47 CFR 80.905(a)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2022
Resolved 11 March 2022
Resolution: Vessel's COI ammended to reflect operations no greater than 1000ft from shore.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 January 2022
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Vessel missing portable bilge pump.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2022
Resolved 18 January 2022
Resolution: Portable bilge pump purchased a placed on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 January 2022
Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Vessel's waterlight battery expired per manufacturer's instructions.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2022
Resolved 18 January 2022
Resolution: New waterlight battery installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 January 2022
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. Vessel's waterlight mounted separate from life ring, preventing connection via lanyard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2022
Resolved 24 January 2022
Resolution: Life buoy and waterlight remounted to allow for connection via lanyard.