MAURY USCG vessel records
← All vessels

PENSACOLA PADDLE PUB

PENSACOLA PADDLE PUB is a passenger vessel (inspected). The Coast Guard has recorded 12 inspections since 2019, most recently in October 2025, along with 14 deficiencies and 1 operational control.

Records from 2019 to 2025. Most recent: inspection, 20 October 2025.

Built
Not recorded
Last inspected
20 October 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 October 2025
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2019–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1548900
Flag
UNITED STATES
Maury page id
psix-1548900

Documentation record

Tonnage as PSIX records it3 - Simplified, Gross Ton
3 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

20 October 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8255836
26 September 2024 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8009845
13 September 2024 Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8002110
7 November 2023 Deficiency Check · Annual Inspection · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7821368
23 May 2023 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7694613
11 May 2022 Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7448600
15 December 2021 Drydock Exam · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7332862
1 March 2021 Annual Inspection · Special Consideration
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7146511
15 April 2020 Administrative Inspection · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6939609
27 February 2020 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6916701
23 December 2019 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6878359
29 January 2019 Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6658305

Deficiency record · 14

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 October 2024 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Alcohol test swabs on board were found to be expired. Replace with valid testing device.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2024
Resolved 21 October 2024
Resolution: Vessel provided proof via photographs
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 October 2024 Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”. Flares were found not protected by watertight case.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2024
Resolved 21 October 2024
Resolution: Vessel provided proof via photographs
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 September 2024 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Fire buckets did not have labeling.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2024
Resolved 21 October 2024
Resolution: Vessel provided proof via photographs.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 September 2024 Resolved
Rails on passenger decks of a ferry or a vessel engaged in excursion trips, including but not limited to sightseeing trips, dinner and party cruises, and overnight cruises, must be at least 1,000 millimeters (39.5 inches) high and must be spaced at intervals of not more than 100 millimeters (4 inches).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2024
Resolved 21 October 2024
Resolution: Vessel provided proof via photographs.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 May 2024 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel owner/operator failed to complete pressure test of pontoons and complete drydock exam. Schedule and complete drydock exam.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2025
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 December 2023 Resolved
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. Marine Inspector found battery in the vessel's ring buoy attached light to be expired. Replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2023
Resolved 4 November 2025
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 14 December 2023 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crew members on inspected vessel's. Marine Inspector found drug program enrollment not current on vessel. Provide current documentation to the satisfaction of the Coast Guard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2023
Resolved 4 November 2025
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 23 May 2023 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crew members on inspected vessels who: (1) Occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection; (2) Perform the duties and functions of patrolmen or watchmen required by this chapter; or, (3) Are specifically assigned the duties of warning, mustering, assembling, assisting, or controlling the movement of passengers during emergencies. Marine employers may form or otherwise use sponsoring organizations, or may use contractors, to conduct the random chemical testing programs required by this part. Neither the captain nor the deckhand were enrolled in a drug testing program meeting the requirements of this part.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2023
Resolution: Vessel rep provided company consortium enrollment, including all crew members, EAP info, and supervisor training. See def documents.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 23 May 2023 Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. Vessel is limited to daylight operations only until an illuminated compass is provided.
Action required: 705 - Other - as specified
Resolved 10 July 2023
Resolution: Received photo of illuminated compass.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 23 May 2023 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with §80.59 once every five years. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. Vessel is limited to operations within 1000 feet of shore until it can provide a Safety Radiotelephony Certificate.
Action required: 705 - Other - as specified
Resolved 4 November 2025
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 23 May 2023 Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements: (1) Where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license. (2) Where the station power exceeds 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a general radiotelephone operator license or higher class license. Vessel is limited to operation within 1000' from shore until the captain or crew can provide a valid radio operator permit.
Action required: 705 - Other - as specified
Resolved 4 November 2025
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 May 2023 Resolved
All cable and wire must: Be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support, except that on vessels of not more than 19.8 meters (65 feet) in length, installations in accordance with paragraph 14.h of ABYC E–8 and paragraph 15.h of ABYC E–9 (both incorporated by reference; see 46 CFR 175.600) are acceptable as meeting the requirements of this section. Cables run under console were not supported.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2023
Resolved 7 June 2023
Resolution: Received picture of cables with supports.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 December 2021 Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.050 in Subchapter Q. Vessel's ring life buoy in non working condition.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 December 2021
Resolved 17 December 2021
Resolution: Satisfactory photo provided.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 15 December 2021 Resolved
Each vessel must be equipped with at least two operable portable battery lights. Vessel missing one portable light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2022
Resolved 20 December 2021
Resolution: Provided video evidence of operable portable lights.