MAURY USCG vessel records
← All vessels

SKY PRINCESS

SKY PRINCESS is a 2019 passenger vessel (inspected). The Coast Guard has recorded 12 inspections since 2019, most recently in June 2026, along with 10 deficiencies and 1 operational control.

Records from 2019 to 2026. Most recent: inspection, 18 June 2026.

Built
2019
Last inspected
18 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9802396
1549792
Flag
BERMUDA
Maury page id
psix-1549792

Inspections, by type

Years with a record 8 calendar years (2019–2026)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it145000 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 12

18 June 2026 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8407577
29 November 2025 COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8275079
2 October 2024 PSC A · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8009421
30 September 2023 Ballast Water Examination · PSC A · COC-CVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7797783
25 February 2023 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7641819
1 February 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7630427
4 October 2022 PSC A · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7571537
2 December 2021 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7361270
18 November 2021 COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7351986
5 April 2020 In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6935680
1 December 2019 COC-CVE Initial · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6863162
8 April 2019 COC-CVE Initial · COC-CVE Initial Prep
Administrative · Activities Europe · Activity 6663813

Deficiency record · 10

07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 30 November 2025 Resolved
07123 - Fire protection systems and fire-fighting systems and applicnaces shall be maintained ready for use. PSCO observed electrical power ventilation control panel missing door latching for proper access to shutdown controls. 74SOLAS20 II-2/14.1.1 - 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 November 2025
Resolved 30 November 2025
Resolution: Arrangements were made for the dooer to properly open as intended.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 November 2025 Resolved
07105 - Fire doors in main vertival zone bulkheads, galley boundaries and staiways enclosure, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10 s from the beginning of their movement. PSCO observed FSD 04.4.30 not close during testing and FSD 05.1.03 close under 3 seconds. 74SOLAS20 II-2/9.4.1.1.5.2 -10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 November 2025
Resolved 6 January 2026
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 30 November 2025 Resolved
07101 - Doors and doorframes in A class divisions with the mean of securing them when closed shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkhead in which the doors are situated. PSCO observed storage in way roller shutter which prevented closure. 74SOLAS20 II-2/9.4.1.1.5.2 - 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 November 2025
Resolved 6 January 2026
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 30 November 2025 Resolved
07101 - Spaces are classified according to their fire risk as shown in categories 1 to 14. A/C station 8.6 is category space 10, storage of combustibles is prohibited. PSCO observed storage of rags, plastic bags, and cleaning supplies stored. Cleaning supplies were also found in fire fighting locker 15.02.02. 74SOLAS20 II-2/9.2.2.3.2.2 -10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 November 2025
Resolved 6 January 2026
01 - Certificates & Documentation › 011 - Ships Certificates › Passenger Ship Safety (including exemption)
Issued 4 October 2022 Resolved
Whenever a defect is discovered, either of which affects the safety of the ship... the master or owner of the ship shall report at the earliest opportunity to the Administration, responsible for issuing the relevant certificate, who shall cause investigations to be initiated to determine whether a survey, as required by regulations 7,8,9, or 10, is necessary. PSCO observed incomplete risk mitigations measures concerning items 2, 3, and 4 as required by the vessel’s Administration Statement (BOSS-STMT-16798-22). 74 SOLAS (20) I/11(c)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2022
Resolution: PSCO observed vessel's implementation of additional mitigation measures concerning 2, 3, and 4 as required by the vessel’s Administration Statement (BOSS-STMT-16798-22). See additional documentation uploaded.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 October 2022 Resolved
Escape doors from public spaces that are normally latched shall be fitted with means of quick release that releases the latch upon the application of a force in the direction of escape flow and... shall not be equipped with any locking device or other arrangement that prevents the release of the latch when pressure is applied to the releasing device. Designated escape routes throughout kid and toddler lounge and aft lounge on Deck 7 had door latch mechanisms that would not release upon application of force in the direction of escape flow. 74 SOLAS (20) II-2/13.3.2.6.2
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 November 2022
Resolution: [name withheld] examined the escape doors provided from the class report. All is satisfactory
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 November 2021 Resolved
Within the perimeter of such stairway enclosures, only public toilets, lockers of non-combustible material providing storage of non hazardous safety equipment and open information counters are permitted. Found numerous stairways with portable hand sanitizing stations in way of landings. 20SOLAS II-2/13.2.3
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 December 2021
Resolution: Received notification and pictures from vessel; fixed sanitation stations to the deck to prevent potential obstructions of escape routes.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 November 2021 Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. Found B-15 double leaf door marked with emergency escape, do not have quick release mechanism. These doors are not part of the emergency escape plan. 20SOLAS II-2/13.3.2.6.2
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 December 2021
Resolution: Attended vessel and verified emergency exit sign removed and in compliance with vessel emergency escape plan.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 December 2019 Resolved
Escape routes shall be maintained in a safe conditiona and clear of obstacles. The Chapel and Conceirge lounge on deck 14 aft share a means of escape into a lobby. The means of escape is obstructed from the lobby into the corridor by a power operated sliding door, which could only be opened manually from the external space. 74 SOLAS (14 Cons.) II-2/13.1.2; 50(a)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 December 2019
Resolved 7 December 2019
Resolution: Class submitted report on 07DEC19 that the door has been kept open, electrical power switched off, and notices displayed on the control panel to prevent operation of the door
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 1 December 2019 Resolved
The company should identify potential emergency shipboard situations and establish procedures to respond to them. The egress route to Lifeboat #5 goes through a retail space. There is no procedure to ensure an unobstructed route is implemented through the space during an emergency. 74 SOLAS (14Cons) IX/3.1; ISM Code Part A/8.1; 40(a)(c)
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 December 2019
Resolved 7 December 2019
Resolution: Class submitted report on 07Dec19 that the procedure to keep evacuation route for LB 5 unobstructed has been implemented onboard.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.