← All vessels
SKY PRINCESS
SKY PRINCESS is a 2019 passenger vessel (inspected). The Coast Guard has recorded 12 inspections since 2019, most recently in June 2026, along with 10 deficiencies and 1 operational control.
Records from 2019 to 2026. Most recent: inspection, 18 June 2026.
- Built
- 2019
- Last inspected
- 18 June 2026
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 10 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9802396
ZCEV9
1549792
Flag
BERMUDA
Maury page id
psix-1549792
Inspections, by type
The 12 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it145000 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 12
18 June 2026
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8407577
29 November 2025
COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8275079
2 October 2024
PSC A · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8009421
30 September 2023
Ballast Water Examination · PSC A · COC-CVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7797783
25 February 2023
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7641819
1 February 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7630427
4 October 2022
PSC A · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7571537
2 December 2021
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7361270
18 November 2021
COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7351986
5 April 2020
In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6935680
1 December 2019
COC-CVE Initial · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6863162
8 April 2019
COC-CVE Initial · COC-CVE Initial Prep
Administrative · Activities Europe · Activity 6663813
Deficiency record · 10
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 30 November 2025
Resolved
07123 - Fire protection systems and fire-fighting systems and applicnaces shall be maintained ready for use. PSCO observed electrical power ventilation control panel missing door latching for proper access to shutdown controls.
74SOLAS20 II-2/14.1.1 - 10c
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 November 2025
Resolved
07105 - Fire doors in main vertival zone bulkheads, galley boundaries and staiways enclosure, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10 s from the beginning of their movement. PSCO observed FSD 04.4.30 not close during testing and FSD 05.1.03 close under 3 seconds.
74SOLAS20 II-2/9.4.1.1.5.2 -10c
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 30 November 2025
Resolved
07101 - Doors and doorframes in A class divisions with the mean of securing them when closed shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkhead in which the doors are situated. PSCO observed storage in way roller shutter which prevented closure.
74SOLAS20 II-2/9.4.1.1.5.2 - 10c
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 30 November 2025
Resolved
07101 - Spaces are classified according to their fire risk as shown in categories 1 to 14. A/C station 8.6 is category space 10, storage of combustibles is prohibited. PSCO observed storage of rags, plastic bags, and cleaning supplies stored. Cleaning supplies were also found in fire fighting locker 15.02.02.
74SOLAS20 II-2/9.2.2.3.2.2 -10c
01 - Certificates & Documentation › 011 - Ships Certificates › Passenger Ship Safety (including exemption)
Issued 4 October 2022
Resolved
Whenever a defect is discovered, either of which affects the safety of the ship... the master or owner of the ship shall report at the earliest opportunity to the Administration, responsible for issuing the relevant certificate, who shall cause investigations to be initiated to determine whether a survey, as required by regulations 7,8,9, or 10, is necessary.
PSCO observed incomplete risk mitigations measures concerning items 2, 3, and 4 as required by the vessel’s Administration Statement (BOSS-STMT-16798-22).
74 SOLAS (20) I/11(c)
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 October 2022
Resolved
Escape doors from public spaces that are normally latched shall be fitted with means of quick release that releases the latch upon the application of a force in the direction of escape flow and... shall not be equipped with any locking device or other arrangement that prevents the release of the latch when pressure is applied to the releasing device.
Designated escape routes throughout kid and toddler lounge and aft lounge on Deck 7 had door latch mechanisms that would not release upon application of force in the direction of escape flow.
74 SOLAS (20) II-2/13.3.2.6.2
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 November 2021
Resolved
Within the perimeter of such stairway enclosures, only public toilets, lockers of non-combustible material providing storage of non hazardous safety equipment and open information counters are permitted. Found numerous stairways with portable hand sanitizing stations in way of landings.
20SOLAS II-2/13.2.3
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 November 2021
Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. Found B-15 double leaf door marked with emergency escape, do not have quick release mechanism. These doors are not part of the emergency escape plan.
20SOLAS II-2/13.3.2.6.2
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 December 2019
Resolved
Escape routes shall be maintained in a safe conditiona and clear of obstacles. The Chapel and Conceirge lounge on deck 14 aft share a means of escape into a lobby. The means of escape is obstructed from the lobby into the corridor by a power operated sliding door, which could only be opened manually from the external space.
74 SOLAS (14 Cons.) II-2/13.1.2; 50(a)
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 1 December 2019
Resolved
The company should identify potential emergency shipboard situations and establish procedures to respond to them. The egress route to Lifeboat #5 goes through a retail space. There is no procedure to ensure an unobstructed route is implemented through the space during an emergency.
74 SOLAS (14Cons) IX/3.1; ISM Code Part A/8.1; 40(a)(c)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.