Records from 2019 to 2023. Most recent: inspection, 22 August 2023.
Inspection history · 26
22 August 2023
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7774269
8 August 2023
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7760434
2 August 2023
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7758773
31 July 2023
Deficiency Check · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7753454
30 January 2023
PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7626077
23 August 2022
Bulk Liquid Transfer Monitor
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7542196
27 July 2022
PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7517507
24 May 2022
Bulk Liquid Transfer Monitor
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7458214
9 February 2022
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7393248
27 January 2022
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7385954
28 July 2021
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7269177
15 March 2021
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7156560
27 January 2021
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7130320
26 October 2020
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7084180
20 August 2020
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7044547
3 August 2020
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7042742
29 July 2020
PSC A · Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7019601
19 July 2020
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7010032
7 July 2020
PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6994998
13 April 2020
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6938600
22 March 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6947257
13 January 2020
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6887991
6 January 2020
Deficiency Check · ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6882612
19 July 2019
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6754365
12 July 2019
In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6746925
3 July 2019
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6721294
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 August 2023
Resolved
Fire detection and fire alarm systems shall be capable of immediate operation at all times and no action by the crew shall be necessary to set it in operation. 01 smoke detector in zone 11 garage and 01 smoke detector in zone 8 hold indicated at fault at the panel. Smoke detectors rendered inoperable.
74 SOLAS (1997)
II-2 / 12.1.1
16AC
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2023
Resolved 22 August 2023
Resolution: Class surveyors noted that there are no current issues with their fire detectors to be found. Report attached.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 31 July 2023
Resolved
07105 - The fire resistance of doors shall, as far as practicable be equivalent to that of the division in which they are fitted. Door fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gas tight & self closing. Engine room door & door leading from cargo hold on main deck do not self close or latch properly. Latching devices on both doors are completely wasted, door will not latch closed.
74 SOLAS (1997) II-2/47.1
17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 August 2023
Resolved 1 August 2023
Resolution: Vessel's crew replaced the main engine room door latching device, adjusted the self-closing mechanism, and cut off the hold back hook from bulkhead.
Vessel's crew repaired the main cargo hold entry door latching device, adjusted the self-closing mechani
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 31 July 2023
Resolved
07105 - Doors shall not be fitted w/hold back hooks. Both door were fitted w/hold back hooks.
74 SOLAS (1997) II-2/47.2
17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 August 2023
Resolved 1 August 2023
Resolution: Main engine room door hold-back device was cut off bulkhead. Main cargo hold entry door hold-back device was removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 July 2022
Resolved
In cargo ships, ventilation fans shall normally be run continuously whenever vehicles are on board. Ventilation fans on cargo decks were not running during cargo operations.
SOLAS 04 II-2 REG 20.3.1.2.2
Action required: 10 - Deficiency Rectified
Due 27 July 2022
Resolved 27 July 2022
Resolution: Crew was trained on the importance of cargo space ventilation and PSCOs verified all ventilation fans were in operating condition.
14 - Pollution Prevention › 148 - Ballast Water › Ballast water report
Issued 27 January 2022
Resolved
The vessel did not file a Ballast Water Management Report with the NBIC within 6 hours allowed after entering port. Additionally, the vessel has frequently visited ports in the United States without filing the report for approximately the last 2 years.
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Due 27 January 2022
Resolved 30 January 2022
Resolution: Vessel Submitted ballast water report.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 27 January 2022
Resolved
Main emergency switch board shall where necessary, nonconducting mats or grating shall be provided at the front and rear of switch board. Vessel did not have nonconductive matting in the engine control room in from of the main electrical switch board.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 January 2022
Resolved 27 January 2022
Resolution: Vessel enginers had the matting in storage and placed it before the Coast Guard departed the vesel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 March 2021
Resolved
The arrangements for the storage, distribution and utilization of oil used in pressure lubrication systems shall be such as to ensure the safety of the ship and persons on board. Vessel has leak on main engine lube oil piping. Resulted in engine plant shutdown and temporary repair of pipe prior to arriving in port of San Juan.
74SOLAS(97) II-2/15.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2021
Resolution: Recieved and reviewed satisfactory class repair report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 August 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship remains fit to proceed to sea without danger to the ship or persons on board. Vessel experienced issues with cylinder #2 and its bearing, rendering the main engine inoperable.
74SOLAS(14)I/reg 11
Action required: 17 - Rectify deficiencies prior to departure
Due 28 August 2020
Resolved 26 October 2020
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 31 July 2020
Resolved
Every inflatable liferaft shall be serviced at intervals not exceeding 12 months. 74SOLAS(14)III/20.8.1.1
Vessel's inflatable liferafts were serviced in May of 2019, due to be serviced again in May of 2020. Flag state, Cyprus, issued letter on 04MAY20 postponing servicing not to exceed 31AUG20. Letter also stated "equipment should be serviced if the vessel calls at a convenient port with available authorized service stations." Vessel has called multiple times in port where liferafts can be serviced over past months. Vessel was also advised to get liferafts serviced as soon as possible by USCG inspectors during exam on 07JUL20.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2020
Resolution: Vessel scheduled servicing in the port of San Juan as per the flag state dispensation letter on August 5, 2020.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 July 2020
Resolved
Cylinders must always be secured and when not in use, must be stowed in a rack in an upright position and have a valve protection cap in place. 46CFR147.60
Several oxygen and acetylene cylinders were found without the protection cap and on side.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2020
Resolved 28 August 2020
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 29 July 2020
Resolved
After any survey of the ship under regulations 7,8,9 or 10 has been conducted, no change shall be made in the structural arrangements of machinery, equipment and other items covered by the survey without the sanction of the administration. 74SOLAS(14)I/11
Received call from command center reporting that subject vessel was taking water into the bilge space/engine room. Upon visiting the vessel, the PSCOs noticed a rupture on the main engine raw water cooling discharge piping (by way of flange). there were also areas of the raw water cooling piping that had visible wasted areas.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2020
Resolution: Vessel replaced piping and presented class report from RINA attesting to proper repair
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 7 July 2020
Resolved
For the protection of the crew, guard rails or bulwarks shall be fitted around all exposed decks. Starboard side handrail on weather deck had 02 broken welds. ICLL/Reg. 25
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 19 July 2020
Resolution: Vessel repaired 02 broken welds on starboard side weather deck hand rail.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 7 July 2020
Resolved
Each transfer pipe used for oil bunkering must be annually tested to 1.5 times the maximum allowable working pressure. Vessel could not provide pressure test records to the bunker lines. Prior to conducting bunkering in U.S. waters, vessel must provide USCG with bunker line test records.
33 CFR 155.820
33 CFR 156.170
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 10 July 2020
Resolution: Bunker lines tested prior to bunkering in a U.S. Port.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 March 2020
Resolved
A main source of electrical power of sufficient capacity to supply all those services mentioned in Regulation 40.1.1 shall be provided. This main source of electrical power shall consist of at least two generating sets. While entering port the vessel lost power.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2020
Resolution: vessel submitted class report.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 January 2020
Resolved
The fire detection and fire alarm systems shall be kept in good order so as to ensure their required performance if a fire occurs. The fire alarms in the engine space were inoperable. 74 SOLAS (2014) II-2/ 14.2.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 6 January 2020
Resolved 11 January 2020
Resolution: all fire detection in the engine room was tested sat.
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 6 January 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present convention to ensure that the ship in all respects will remain fit to proceed to sea. The oil content meter was inoperable and presenting an error message. MARPOL ANNEX I/6.4.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2020
Resolved 11 January 2020
Resolution: oil content meter was replaced and tested sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 January 2020
Resolved
The ring, lines, and letters shall be painted in the black on a light background. The deck line was painted yellow on the yellow hull. ILLC CH1 Reg 8
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 January 2020
Resolved 11 January 2020
Resolution: deck line was repainted black.
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 6 January 2020
Resolved
The maintenance checklists provided by the safety management system is inadequate and do not clearly state what fire detection systems should be tested. fire detection in the engine room was not operational. there is no system of records to identify which fire detection zones have been tested previously and there is no history of fire detection tests in the engine room. the vessel’s safety management system does not specify which fire alarms are being tested and at what instances’ they are to be tested.
74 SOLAS (2014) IX/ 3.1 ISM CODE 10.3
Condition: Invalid
Action required: 30 - Ship detained
Due 7 January 2020
Resolved 11 January 2020
Resolution: the maintenance checklist for the fire detectors was updated to include which fire detectors were tested annually.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 July 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Auxiliary engine #1(generator) shut down due to governor malfunction. All power was transferred to auxiliary engine #3(generator)causing a over speed and shutdown resulting in a ship blackout. Provide flag attestation to proper repair of Auxiliary engine #1 - 74 SOLAS (2014) I/11(a) - 17bc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 July 2019
Resolution: MSD STT has received RINA survey endorsement stating the repair to diesel generator #1 and been completed to the satisfaction of the recognized organization on behalf of the administration. Deficiency has been cleared and operational control is removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 July 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. The primary lube oil pipe for the main diesel engine has a 2” hole which is leaking lube oil into the bilge. 74SOLAS(14) I/11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 July 2019
Resolution: Pipe replaced. Class report provided.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 3 July 2019
Resolved
Nautical charts necessary for the intended voyage shall be adequate and up to date. Vessel does not have paper charts for intended voyages for ports in Caribbean region (San Juan, St. Thomas and St. Croix). 74SOLAS(14) V/27
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 July 2019
Resolution: Reciept for purchase of paper charts provided for applicable areas.
01 - Certificates & Documentation › 011 - Ships Certificates › Documents for carriage of dangerous goods
Issued 3 July 2019
Resolved
United States requires HAZMAT training every 3 years for HAZMAT employees. No one handling HAZMAT onboard has current HAZMAT training. HAZMAT training will be required prior to handling hazardous cargo in U.S. Waters. 49 CFR 172.704 (c)(2)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 July 2019
Resolution: HAZMAT course completion certificates provided for 06 crewmembers.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 3 July 2019
Resolved
For equipment presenting hazards to personnel, protective fencing or shielding for the moving parts must be provided. Main service generators have unshielded moving parts. ILO 147/PWSA 33 USC 1223(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2019
Resolved 19 July 2019
Resolution: Vessel installed guards for moving parts on generators
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 July 2019
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in a normal manner. The amperage meter gauge for the generator battery charger control panel is missing, exposing inner components of control panel. 74SOLAS(97) II-1/ 45.1.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2019
Resolved 19 July 2019
Resolution: Vessel sent images of replaced amperage meter gauge.