MAURY USCG vessel records Sign in
← All vessels

MM-126

MM-126 is a 2019 tank barge. The Coast Guard has recorded 8 inspections since 2019, most recently in December 2025, along with 4 deficiencies.

Records from 2019 to 2025. Most recent: inspection, 11 December 2025.

Built
2019
Last inspected
11 December 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

1551560
Flag
UNITED STATES
—
Maury page id
psix-1551560

Inspections, by type

Years with a record 7 calendar years (2019–2025)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCONRAD SHIPYARD LLC · MORGAN CITY, LA, UNITED STATES · built 2019
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 October 2025 · expires 30 November 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 8

11 December 2025 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8277287
13 November 2024 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 8034351
27 September 2024 Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8008254
29 December 2023 MTSA Verification · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7843110
15 December 2022 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7606106
13 December 2021 Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7366021
27 October 2020 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7087303
14 August 2019 Construction Oversight · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6785209

Deficiency record · 4

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 December 2023 Resolved
The owner, master, or person-in-charge of a tank vessel must ensure that portable and semi-portable extinguishers are inspected and maintained in accordance with NFPA 10. No evidence on board vessel found to indicate that monthly inspections have been completed. Provide evidence that monthly inspections have been completed or have fire extinguishers re-certified by a qualified NFPA technician and inspect monthly as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 January 2024
Resolved 5 January 2024
Resolution: Received objective evidence that fire extinguishers were re-inspected by a certified technician. Also discussed issue with company compliance officer who stated that they are implementing a new procedure to ensure monthly inspections are being completed.
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 13 December 2021 Resolved
All valves, flanges, fittings, and accessory equipment shall have a pressure rating at operating temperatures not less than the maximum allowable pressure to which they may be subject. The cargo loading/discharge valves on the #1 and #3 Port cargo tanks were leaking past the packing gland. Make repairs to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 December 2021
Resolved 13 December 2021
Resolution: Valves were tightened and the leaking stopped.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 13 December 2021 Resolved
Hose used to transfer oil or hazardous material must meet the requirements of 154.500 of this chapter... Each hose also must be marked with the following... Maximum allowable working pressure (MAWP). The cargo piping was not marked with the MAWP. Mark the cargo piping with the MAWP to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 December 2021
Resolved 13 December 2021
Resolution: The cargo piping was marked with the MAWP.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 27 October 2020 Resolved
Emergency shutodwn for ME was not closing properly and shutting down engine.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 October 2020
Resolved 27 October 2020
Resolution: took the slack out of the shutdown down pull wire which created better tension which alloed the flap to completely close off air to the engine and allowed for the shutdown.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.