Records from 1987 to 2010. Most recent: inspection, 1 March 2010.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 48
1 March 2010
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3689235
11 February 2009
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3411541
6 March 2008
Hull Examination · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3162243
18 April 2007
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2908609
22 February 2007
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2876272
15 March 2006
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2602274
3 October 2005
COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2506416
9 December 2004
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2265590
4 November 2004
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2234580
15 June 2004
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2099452
24 March 2004
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2029872
6 November 2003
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1942984
4 March 2003
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1751821
16 January 2003
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1726604
3 June 2002
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1625569
10 April 2002
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1604147
22 January 2002
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1475250
26 December 2001
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1473874
4 October 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1429631
3 October 2000
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1466168
17 February 2000
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1466167
20 January 1999
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1378589
23 April 1998
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1461892
14 January 1998
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 773625
10 December 1997
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1446570
5 February 1997
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1396653
1 April 1996
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1452138
20 December 1995
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1078843
20 January 1995
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1191801
19 December 1994
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 858945
3 March 1994
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1164641
27 January 1994
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 851683
19 January 1994
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1161757
25 October 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 664534
31 July 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 155770
18 May 1993
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1145585
25 February 1993
Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1145477
24 January 1992
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1268512
22 November 1991
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 956981
24 October 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1226520
26 September 1990
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 899350
11 July 1990
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1222958
27 September 1989
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 995928
23 February 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1347083
11 January 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1198634
1 November 1988
Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 894696
22 April 1988
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1312821
16 June 1987
Initial Certification · Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1312312
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 6 June 2007
Resolved
Provide service report for fix firefighting system
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2007
Navigation › Piloting/Steering › Marine Charts
Issued 18 April 2007
Resolved
Provide chart
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2007
Operations/Management › Casualty Reporting/Post-Casualty Actions › Determination of Alcohol/Drug Use
Issued 18 April 2007
Resolved
Provide test kit for SMI testing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 April 2007
Resolved
Provide clips for deck rails.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2007
Documentation › Markings/Placards › Lifejacket Placard
Issued 18 April 2007
Resolved
Post lifejacket donning placard , emergency inst and COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 18 April 2007
Resolved
Provide one BII fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2007
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 18 April 2007
Resolved
Provide two portable lights.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2007
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 22 February 2007
Resolved
Vessel restricted from the carriage of passengers until satisfactory Annual examination is conducted.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2007
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 15 March 2006
Resolved
Restrap / remount both port and starboard muffler pipes.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2006
Resolved 5 April 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 15 March 2006
Resolved
Make permanent repairs to the STBD rubrail amidships.
Action required: 705 - Other - as specified
Due 29 March 2006
Resolved 5 April 2006
Construction/Loadline › Hull › Side Shell
Issued 15 March 2006
Resolved
Treat surface rot throughout the vessel.
Action required: 705 - Other - as specified
Due 29 March 2006
Resolved 5 April 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 3 October 2005
Resolved
Prior to operation, conduct emergency drills in the presence of a Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 November 2005
Resolved 23 November 2005
Documentation › Logs/Records › Drug Test Records
Issued 3 October 2005
Resolved
Provide all drug and alcohol program information I.A.W. provided DAPI checksheet.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 November 2005
Resolved 23 November 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 3 October 2005
Resolved
Provide service report for the fixed firefighting system. (expired Nov 2004)
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 November 2005
Resolved 23 November 2005
Construction/Loadline › Hull › Side Shell
Issued 3 October 2005
Resolved
At next drydock (MAR 2006) make permanent repairs to the rubrails in way of rotted areas.
Action required: 705 - Other - as specified
Due 4 March 2006
Resolved 20 March 2006
Resolution: Vessel currently in drydock undergoing said repairs
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 3 October 2005
Resolved
Remove all excess oil from the bilges in the engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 November 2005
Resolved 23 November 2005
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 3 October 2005
Resolved
Provide lanyard and non-corrosive clip for ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 November 2005
Resolved 23 November 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 3 October 2005
Resolved
Mount both portable fire extinguishers with proper bracket.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 November 2005
Resolved 23 November 2005
Fire Fighting › Fire Bucket › Lanyard
Issued 3 October 2005
Resolved
Properly mark and place lanyard on (1) fire bucket.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 November 2005
Resolved 23 November 2005
Engineering › Bilge Water Management System › Not Operational
Issued 3 October 2005
Resolved
Make permanent repairs to both the bilge pump and the bilge high level alarms in the engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 November 2005
Resolved 23 November 2005
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 3 October 2005
Resolved
Make forward modular smoke detector operational.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 November 2005
Resolved 23 November 2005
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 4 November 2004
Resolved
Provide evidence that vessel's crewmembers are enrolled in a random drugtesting program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2004
Resolved 15 November 2004
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 4 November 2004
Resolved
Provide log entries proving that safety drills are being conducted.
Action required: 705 - Other - as specified
Due 18 November 2004
Resolved 9 December 2004
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 4 November 2004
Resolved
Provide proof of user fee payment.
Action required: 705 - Other - as specified
Due 18 November 2004
Resolved 15 November 2004
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 4 November 2004
Resolved
Provide buoyant lifeline for ring lifebuoy.
Action required: 705 - Other - as specified
Due 18 November 2004
Resolved 15 November 2004
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 4 November 2004
Resolved
Provide valid state registration.
Action required: 705 - Other - as specified
Due 18 November 2004
Resolved 15 November 2004
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 4 November 2004
Resolved
Provide two emergency lights.
Action required: 705 - Other - as specified
Due 18 November 2004
Resolved 15 November 2004
Construction/Loadline › Hull
Issued 24 March 2004
Resolved
REMOVE MINOR ANGEL HAIR ROT THROUGHOUT BILGES AND INTERNAL SIDESHELL OF VESSEL AND TREAT WITH PERSERVATIVE SOLUTION.
Due 24 June 2004
Resolved 15 June 2004
Resolution: Angel hair rot removed. Areas in question were treated with a salt water brine solution.
Operations/Management › Drills/Instruction
Issued 6 November 2003
Resolved
Conduct Fire, Abandon ship, and Man overboard drills monthly, log same and send copy to MSD Ft. Myers with Masters name and license number.
Due 6 December 2003
Resolved 24 March 2004
Fire Fighting › Miscellaneous Items
Issued 6 November 2003
Resolved
Provide two additional fire buckets onboard vessel.
Due 6 December 2003
Resolved 7 November 2003
Engineering › Bilge Water Management System › Pump
Issued 6 November 2003
Resolved
Provide a portable bilge pump onboard vessel.
Due 6 December 2003
Resolved 7 November 2003
Construction/Loadline › Structures
Issued 16 January 2003
Resolved
REPAIR MAIN DECK AT PORT STERN WHERE SOFT. LEGACY COMPONENT DESC: Deck Plating
Due 16 February 2003
Resolved 4 March 2003
Communications › Audible Communications
Issued 16 January 2003
Resolved
REPAIR VESSELS HORN. LEGACY COMPONENT DESC: Horn/Whistle
Due 16 February 2003
Resolved 4 March 2003
Communications › Alarms/Indicators
Issued 16 January 2003
Resolved
INSTALL BILGE ALARM IN FORWARD BILGE. LEGACY COMPONENT DESC: Bilge Alarm
Due 16 February 2003
Resolved 4 March 2003
Engineering › Steering Gear System
Issued 16 January 2003
Resolved
INSTALL COTTER PIN IN RAM/QUADRANT CONNECTION . LEGACY COMPONENT DESC: Fastener
Due 16 February 2003
Resolved 4 March 2003
Operations/Management › Drills/Instruction
Issued 16 January 2003
Resolved
PRIOR TO OPERATION; CONDUCT FIRE AND MAN OVERBOARD DRILLS UNDERWAY, LOG AND FAX SAME TO MSD FT. MYERS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 February 2003
Resolved 4 March 2003
Fire Fighting › Miscellaneous Items
Issued 16 January 2003
Resolved
PROVIDE TWO ADDITIONAL FIRE BUCKETS ONBOARD.
Due 16 February 2003
Resolved 4 March 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 10 April 2002
Resolved
INSTALL BULWARKS OR RAIL COURSES SO NO SPACE IS GREATER THAN 4 INCHES. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper Installation
Due 10 May 2002
Resolved 3 June 2002
Communications › Alarms/Indicators
Issued 10 April 2002
Resolved
REPAIR/REPLACE HIGH BILGE ALARM IN MACHINERY SPACE. VESSEL MASTER IS TO CONDUCT VISUAL INSPECTIONS UNTIL CORRECTED. LEGACY COMPONENT DESC: High Water Alarm
Condition: Improper/Lack of Maintenance
Due 10 May 2002
Resolved 3 June 2002
Lifesaving
Issued 4 October 2001
Resolved
Label PFD deck boxes with amount and type of PFD's stowed inside.
Condition: Unknown
Due 4 November 2001
Resolved 10 April 2002
Fire Fighting
Issued 4 October 2001
Resolved
Provide three (3) 2.5gl fire buckets.
Condition: Unknown
Due 4 November 2001
Resolved 10 April 2002
Lifesaving
Issued 4 October 2001
Resolved
Provide proof of conducting emergency drills.
Condition: Unknown
Due 4 November 2001
Resolved 10 April 2002
Navigation
Issued 4 October 2001
Resolved
Provide Coast Pilot [name withheld], Navigation Rules.
Condition: Unknown
Due 4 November 2001
Resolved 10 April 2002
Construction/Loadline
Issued 4 October 2001
Resolved
Repair "soft spot" approx. 10"x12" area on main deck.
Condition: Unknown
Due 4 November 2001
Resolved 10 April 2002
Accommodation/Occupational Safety
Issued 4 October 2001
Resolved
Mark forward escape hatch "Emergency Exit Keep Clear" in 2" high letters.
Condition: Unknown
Due 4 November 2001
Resolved 10 April 2002
Construction/Loadline
Issued 4 October 2001
Resolved
Provide visual indicator of bilge pump operation for accommodation space.
Condition: Unknown
Due 4 November 2001
Resolved 10 April 2002
Construction/Loadline
Issued 4 October 2001
Resolved
Repair/replace float switch in accommodation space.
Condition: Unknown
Due 4 November 2001
Resolved 10 April 2002
Electrical
Issued 4 October 2001
Resolved
Provide two (2) flashlights.
Condition: Unknown
Due 4 November 2001
Resolved 10 April 2002
Documentation
Issued 4 October 2001
Resolved
Provide Captain's license for route and tonnage.
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Navigation
Issued 3 October 2000
Resolved
PROVIDE AND POST EMERGENCY BROADCAST PLACARD
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Documentation
Issued 3 October 2000
Resolved
PROVIDE FIRST AID/CPR TRAINING FOR 50 PERCENT OF CREW, PROVIDE DOCUMENTATION UPON COMPLETION
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Lifesaving
Issued 3 October 2000
Resolved
PROVIDE UPDATED FIRST AID KIT
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Fire Fighting
Issued 3 October 2000
Resolved
PROVIDE APPROVED PLANS FOR FIXED FIREFIGHTING SYSTEM.
Condition: Unknown
Due 7 April 2001
Resolved 10 April 2002
Fire Fighting
Issued 3 October 2000
Resolved
PROVIDE AND MOUNT B-I PORTABLE FIRE EXTINGUISHER
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Lifesaving
Issued 10 December 1997
Resolved
PROVIDE/POST PFD DONNING INSTRUCTIONS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 January 1998
Resolved 15 January 1998
Engineering
Issued 10 December 1997
Resolved
RELABEL EMERGENCY FUEL SHUT OFF'S._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 January 1998
Resolved 15 January 1998
Engineering
Issued 10 December 1997
Resolved
REINSTALL CLAMP ON STARBOARD EXHAUST._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 January 1998
Resolved 15 January 1998
Accommodation/Occupational Safety
Issued 10 December 1997
Resolved
RENEW CRACKED WINDSHIELD GLASS.
Condition: Unknown
Due 15 January 1998
Resolved 15 January 1998
Lifesaving
Issued 10 December 1997
Resolved
PROVIDE SUITABLE RESCUE LADDER.
Condition: Unknown
Due 15 January 1998
Resolved 15 January 1998
Lifesaving
Issued 10 December 1997
Resolved
RELABEL PFD STOWAGE-ADULT AND CHILD.
Condition: Unknown
Due 15 January 1998
Resolved 15 January 1998
Engineering
Issued 5 February 1997
Resolved
LABEL EMERGENCY FUEL SHUT-OFF._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 February 1997
Resolved 17 March 1997
Lifesaving
Issued 5 February 1997
Resolved
LABEL FLARE CONTAINER DISTRESS SIGNALS, PAINT CONTAINER BRIGHT COLOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 February 1997
Resolved 17 March 1997
Fire Fighting
Issued 5 February 1997
Resolved
PROVIDE 3 2 1/2 GL FIRE BUCKETS, LABEL AS SUCH, ATTACH LANYARDS TO EACH._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 February 1997
Resolved 17 March 1997
Construction/Loadline
Issued 5 February 1997
Resolved
PROVE OPERATION OF AND PERMANENTLY MOUNT FWD BILGE PUMP._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 February 1997
Resolved 17 March 1997
Electrical
Issued 20 December 1995
Resolved
HARDWIRE VHF RADIO AND CABIN COURTESY LIGHTS.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Engineering
Issued 20 December 1995
Resolved
REPAIR WATER LEAKS ON BOTH EXHAUST LINES.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Lifesaving
Issued 20 December 1995
Resolved
LABEL CHILD PFD STOWAGE AND NUMBER OF PFDS.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Engineering
Issued 19 December 1994
Resolved
Double clamp all raw water hoses to main engine and at exhaust outfalls.
Condition: Unknown
Due 19 December 1994
Resolved 19 December 1994
Fire Fighting
Issued 19 December 1994
Resolved
Recharge 1 B-II fire extinguisher prior to carrying passengers.
Condition: Unknown
Due 19 December 1994
Resolved 19 December 1994
Unknown
Issued 19 December 1994
Resolved
Provide proof of drug testing.
Condition: Unknown
Due 19 December 1994
Resolved 19 December 1994
Lifesaving
Issued 19 December 1994
Resolved
Repair ring buoy water light.
Condition: Unknown
Due 19 December 1994
Resolved 19 December 1994
Fire Fighting
Issued 25 February 1993
Resolved
Provide one additional B-II fire ext.
Condition: Unknown
Due 8 March 1993
Resolved 8 March 1993
Documentation
Issued 25 February 1993
Resolved
Provide renewal stickers for documentation.
Condition: Unknown
Due 8 March 1993
Resolved 8 March 1993
Lifesaving
Issued 25 February 1993
Resolved
Provide 4 additional adult pfd's.
Condition: Unknown
Due 8 March 1993
Resolved 8 March 1993
Lifesaving
Issued 25 February 1993
Resolved
Renew 6 orange and 3 red flares and provide watertight container.
Condition: Unknown
Due 8 March 1993
Resolved 8 March 1993
Engineering
Issued 25 February 1993
Resolved
Demonstrate proper operation of propulsion engine, bilge pumps, and nav lights.
Condition: Unknown
Due 8 March 1993
Resolved 8 March 1993
Electrical
Issued 25 February 1993
Resolved
Properly wire VHF radio. Wiper motors and deck lights.
Condition: Unknown
Due 8 March 1993
Resolved 8 March 1993
Engineering
Issued 22 November 1991
Resolved
RENEW HOSE CLAMPS FOR DIESEL ENG SEA SUCTION (INBOARD OF SEA VALVE)
Condition: Unknown
Due 29 November 1991
Resolved 12 February 1992
Engineering
Issued 22 November 1991
Resolved
REVIEW HOSE CLAMPS ON DIESEL ENGINE EXHAUST PIPING.
Condition: Unknown
Due 29 November 1991
Resolved 12 February 1992
Lifesaving
Issued 26 September 1990
Resolved
PROVIDE WATERLIGHT FOR RINGBUOY.
Condition: Unknown
Due 26 September 1990
Resolved 26 September 1990
Documentation
Issued 26 September 1990
Resolved
PROVIDE GARBAGE PLACARD AND GARBAGE MAINTENANCE PLAN.
Condition: Unknown
Due 26 September 1990
Resolved 26 September 1990
Engineering
Issued 27 September 1989
Resolved
REPAIR REMOTE FUEL SHUTOFFS.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Fire Fighting
Issued 27 September 1989
Resolved
PROVIDE USCG APPROVED TYPE BRACKET FOR B-I FIRE EXTINGUISHER.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Documentation
Issued 27 September 1989
Resolved
PROVIDE EMERGENCY CHECKOFF.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Documentation
Issued 27 September 1989
Resolved
PROVIDE FCC STATION LICENSE.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Lifesaving
Issued 27 September 1989
Resolved
PROVIDE 3 ORANGE FLARES.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Lifesaving
Issued 27 September 1989
Resolved
PROVIDE RINGBUOY WATERLIGHT BRACKET.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Documentation
Issued 27 September 1989
Resolved
PAINT HOMEPORT ON STERN.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Documentation
Issued 27 September 1989
Resolved
PAINT VSL NAME ON P&S BOWS.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Engineering
Issued 1 November 1988
Resolved
ADJUST PORT & STBD EMERGENCY FUEL CUT-OFF VALVES TO INSURE 100% CLOSING. MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Lifesaving
Issued 1 November 1988
Resolved
RELABLE PFD STORAGE COMPARTMENT INSIDE CABIN PORT & STBD SIDE. MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Construction/Loadline
Issued 1 November 1988
Resolved
RENEW STBD WINDSHIELD GLASS IWO BROKEN GLASS. MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Fire Fighting
Issued 1 November 1988
Resolved
PROVIDE PORTABLE HAND BILGES/FIRE PUMP WITH ENOUGH HOSE TO REACH FROM BILGETO OVERBOARD. MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Accommodation/Occupational Safety
Issued 1 November 1988
Resolved
REFASTEN ALL LIFE RAILS WHERE LOOSE. MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Engineering
Issued 1 November 1988
Resolved
RENEW PORT & STBD FUEL VENT FLAME SCREENS WITH 30X30 WIRE MESH. MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Documentation
Issued 1 November 1988
Resolved
PROVIDE COPY OF NAVIGATION RULE BOOK. MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Fire Fighting
Issued 1 November 1988
Resolved
SERVICE (1) TYPE II DRY CHEM FIRE EXTINGUISHER (WITH JUN87 SERVICE LABEL) LOCATED STBD SIDE. MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Electrical
Issued 1 November 1988
Resolved
PROVIDE TEST OF MAIN ENGINE & STEERING SYSTEM. MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Navigation
Issued 1 November 1988
Resolved
PROVIDE EMERGENCY LIGHTING (FLASHLIGHT). MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Lifesaving
Issued 16 June 1987
Resolved
PROVIDE SEVEN (7) ADDITIONAL APPROVED ADULT LIFE PRESERVERS FOR A TOTAL OF 53 ON BOARD. THE TOTAL PERSONS ALLOWED IS REDUCED TO 46 UNTIL THE ABOVEIS COMPLETED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR BUT NOT LATER THAN 30JUN87.
Condition: Unknown
Due 16 June 1987
Resolved 16 June 1987
Lifesaving
Issued 16 June 1987
Resolved
STENCILE THE VESSEL'S NAME ON ALL LIFE PRESERVERS AND LIFE RING.
Condition: Unknown
Due 16 June 1987
Resolved 16 June 1987