← All vessels
ATHERINA
ATHERINA is a tank ship. The Coast Guard has recorded 5 inspections since 2019, most recently in June 2025, along with 1 deficiency.
Records from 2019 to 2025. Most recent: inspection, 27 June 2025.
- Built
- Not recorded
- Last inspected
- 27 June 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 1 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9445473 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5SA5
1552598
Flag
LIBERIA
—
Maury page id
psix-1552598
Inspections, by type
The 5 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it169919 - Convention (Subpart B), Gross Ton
169919 - Regulatory (Subpart C or D), Gross Ton
319470 - Dead Weight, Ton
370236 - Displacement, Ton
102202 - Convention (Subpart B), Net Ton
102202 - Regulatory (Subpart C or D), Net Ton
169919 - Regulatory (Subpart C or D), Gross Ton
319470 - Dead Weight, Ton
370236 - Displacement, Ton
102202 - Convention (Subpart B), Net Ton
102202 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 5
27 June 2025
Deficiency Check · COC-TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8167122
3 January 2021
PSC B · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7116053
10 March 2020
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6923896
15 October 2019
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6834705
19 July 2019
COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6750645
Deficiency record · 1
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 27 June 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed inoperable inert gas pressure sensor in 5 center COT.
74 SOLAS (2020) I/11
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.