Records from 2018 to 2026. Most recent: inspection, 27 May 2026.
Inspection history · 55
27 May 2026
Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 8381626
26 May 2026
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8380592
8 May 2026
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8369284
26 April 2026
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8356526
23 April 2026
COC-CVE Annual · PSC A
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8354729
11 October 2025
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8256392
24 September 2025
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8240263
10 August 2025
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8206426
8 August 2025
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8205392
4 August 2025
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8201816
31 July 2025
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8199615
30 July 2025
Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 8198168
23 July 2025
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8192647
16 July 2025
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8187000
16 July 2025
Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 8187115
13 July 2025
Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8185343
1 July 2025
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8172417
25 June 2025
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8167012
17 June 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8161475
16 June 2025
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8162157
3 June 2025
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8150782
19 May 2025
PSC B
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8138984
15 May 2025
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8136625
14 May 2025
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8135954
13 May 2025
Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 8134769
9 May 2025
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8131726
9 May 2025
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8136101
6 May 2025
COC-CVE Annual · PSC A · Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8127527
1 April 2024
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7888011
18 October 2023
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7810642
18 October 2023
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7810647
31 May 2023
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7701451
22 May 2023
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7694087
27 April 2023
Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7675836
22 March 2023
PSC A · COC-CVE Annual
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7654832
28 February 2023
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7646849
2 February 2023
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7631467
26 October 2022
Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7583695
24 October 2022
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7605829
23 October 2022
PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7582373
22 October 2022
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7582997
27 September 2022
COC-CVE Quarterly
Type not classified · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7563423
25 May 2022
In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7458947
19 May 2022
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7454348
14 April 2022
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7430756
6 April 2022
COC-CVE Annual · PSC A
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7425801
8 October 2020
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7073305
12 December 2019
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6874504
5 June 2019
COC-CVE Annual
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6699383
16 May 2019
ISPS III Exam · PII Safety Exam · Ballast Water Examination · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6669681
29 October 2018
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6570031
17 September 2018
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6542494
4 September 2018
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6531563
24 August 2018
Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6521748
21 June 2018
COC-CVE Initial · COC-CVE Initial Prep
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6451652
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 April 2026
Resolved
For determining the appropriate fire integrity standards to be applied to boundaries between adjacent spaces, such spaces are classified according to their fire risk as shown in categories (1) to (14) below. Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, it shall be treated as a space within the relevant category having the most stringent boundary requirements. The title of each category is intended to be typical rather than restrictive. The number in parentheses preceding each category refers to the applicable column or row in the tables. PSCO discovered combustible material stowed in HVAC #6 and HVAC #3, category 10 spaces.
Cite: 74 SOLAS 01 II-2/26.2.2
Code: 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2026
Resolved 23 April 2026
Resolution: Combustible materials were removed from the spaces.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 April 2026
Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures shall satisfy the following requirements: The doors shall be self-closing and be capable of closing against an angle of inclination of up to 35 degrees opposing closure. PSCO observed fire screen #237 did not latch fully closed.
Cite: 74 SOLAS 01 II-2/30.4.1
Code: 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2026
Resolved 23 April 2026
Resolution: Doors were adjusted to latch fully closed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 April 2026
Resolved
Ships shall be provided with the fire-extinguishing appliances that are readily available. PSCO discovered two fire stations missing spanner wrenches located on pport side, deck 5 IWO life boat #2, and deck 4 IWO HVAC #3.
Cite: 74 SOLAS 01 II-2/10.1
Code: 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2026
Resolved 23 April 2026
Resolution: Spanner wrenches were replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 May 2025
Resolved
Under all sailing conditions, including maneuvering ,the speed, direction of thrust and, if applicable, the pitch of the propeller shall be fully controllable from the navigational bridge.
Vessel reported starboard azipod malfunctioned, was unresponsive to helm commands and operated independently of helm commands, while transiting the Detroit River. Starboard main engine was secured as the malfunctioning azipod was affecting safe navigation of the vessel. Vessel anchored at Belle Isle Anchorage for troubleshooting. Captain of the Port is requiring vessel, prior to movement, to submit causal report from Classification Society (1) identifying the contributing factors that led to the issue, (2) certifying that any necessary repairs have been satisfactorily completed, and (3) the vessel is fit for its intended route and service.
SOLAS 24 II-1/49.1 Code 60ac.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 9 May 2025
Resolved 9 May 2025
Resolution: Rcv'd technician and class report testiing repair and fully operation azipods and vsl manueverability.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 6 May 2025
Resolved
Fire Doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, double-leaf doors equipped with a latch necessaryto their fire integrity shall have a latch that is automatically activiated by the operation of the doors when released by the system. Double-leaf fire door FD 237 will not latch when closed. 74 SOLAS 01 II-2/30.4.12 (10C)
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 6 May 2025
Resolved 6 May 2025
Resolution: Deficiency rectified prior to departing.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 May 2025
Resolved
Every Passenger ship shall carry lifejackets for not less than 5% of the total number of persons onboard. These lifejackets shall be stowed in conspicious places on deck or at muster stations. Lifejacket stowage locker deck 4 starboard missing one adult life jacket.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 6 May 2025
Resolved 6 May 2025
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 6 May 2025
Resolved
Every ship of 12M or more in length overall and fixed or floating platfomrs shall display placards which notify the crew and passengers of the discharge requirements of regulation 3,4,5 and 6 of this annex. Where the ship carries passengers, placards also should be placed in prominent places where passengers are accomodated and congregate. These include cabins, all deck areas for recreational purposes. MARPOL placards were not diplayed in these areas.
cite MARPOL 2017 Annex V 10.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 6 May 2025
Resolved 6 May 2025
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 May 2025
Resolved
The activiation of any detector or manually operated call point shall initiate a visual ans audible fire signal at the control panel and indicating units. if the signals have not received attention within 2 minutes an audible alarm shall be automatically sounded throughout the crew accomodation and service spaces, control stations and machinery spaces of category A. Manual call points in aft lounge deck 2 are not operable.
Condition: Improper/Lack of Maintenance
Due 6 May 2025
Resolved 6 May 2025
Resolution: Vessel fixed this prior to the team departing.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Compliance (COC)
Issued 18 October 2023
Resolved
Vessel must complete a satisfactory Certificate of Compliance Exam by the United State Coast Guard prior to carrying US citizens as passengers or embarking passengers in U.S. ports.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 October 2023
Resolved 6 May 2025
Resolution: Satisfactory exam conducted. COC issued.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 22 March 2023
Resolved
Each operation described in paragraph 2 of this regulation shall be fully recorded without delay in the Oil Record Book Part 1, so that all entries in the book appropriate to that operation are completed. ORB entry on 29 Jan 2023 was improperly denoted as a code "E" according to ORB instruction. MARPOL 2017 Annex I/17.4.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2023
Resolved 27 April 2023
Resolution: Chief engineer provided training to all engineering staff. Saw documentation of training.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 22 March 2023
Resolved
All life-saving appliances and arrangments shall comply with the applicable requirements of the Code. Except as otherwise stated, the normal equipment of every rescue boat shall consist of a searchlight with a horizontal and vertical sector of at least 6 degrees and a measured liminous intensity of 2,500 cd which can work continuously for not less than 3 hours. PSCO observed that the fuse was missing for Rescue Boat #2 search light causing the light to be inoperational. 74 SOLAS 20 III/34, LSA Code 5.1.2.2.11.
Action required: 10 - Deficiency Rectified
Resolved 28 March 2023
Resolution: Installed new fuse and completed operational check of searthlight.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 22 March 2023
Resolved
Where "A" class divisions are penetrated for the passage of electric cables, pipes, trunks, ducts, etc., or for girders, beams or other structural members, arrangments shall be made to ensure that the fire resistance is not impaired. Electrical penetration through class "A" penetration in HVAC Room #3 has improper installation of electrical cables through the marine cable transit. 74 SOLAS 01 II-2/18.1.1.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2023
Resolved 27 April 2023
Resolution: Proper installation of electrical cables was verified in HVAC Room #3.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 22 March 2023
Resolved
Two means of escape shall be provided from each machinery space. STBD side exit from machinery space to the bunker station improperly locked with use of a key lock from the interior preventing escape from the engine room. Emergency hatch from bunker station to galley was locked from interior, restricitng access to lifeboats or liferafts from the bunker station. 74 SOLAS 01 II-2/28.3.1.1.
Action required: 10 - Deficiency Rectified
Resolved 28 March 2023
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 23 October 2022
Resolved
All life-saving appliances and arrangements shall comply with the provisions of the code. The normal equipment of every lifeboat shall consist of a food ration as described in paragraph 4.1.5.1.18 totalling not less that 10,000 kj for each person the life boat is permitted to accomodate. PSCO found 184 food rations expired in August 2022; crew requested new rations (in accordance with SMS) in July 2022, but have not recieved the rations on board from the company.
SOLAS (20) III/34 LSA CH. 4.4.4.8.12
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 23 October 2022
Resolved 26 October 2022
Resolution: SNNE Personnel attended vessel and verified that unexpired food rations had been delivered.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 October 2022
Resolved
The means provided in paragraph 2.2.3.5.2 (oil level gauge in place of sounding pipes) which are acceptable to the Administration shall be maintained in the proper condition to ensure their continued accurate functionin in service. PSCO found the port diesel day tank (8,357 gal) lower sight glass push-button stop valve to be held open in place with a wooden dowel, rendering the closing mechanism inoperable.
SOLAS (04) II-2/4.2.2.3.5.3
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 23 October 2022
Resolved 23 October 2022
Resolution: Corrected by engineering crew prior to departure.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 27 September 2022
Resolved
Means shall be provided for bringing the davit-launched survival craft against the ship's side and holding them alongside so that persons can be safely embarked. PSCOs observed the 2 outboard (port) boats were not positioned adjacent to the ship with the forward end out substantially creating a large gap making it unsafe for passenger embarkation. When the crew tried to adjust the lifeboats the lifeboats turned inward making the dangerous situation even more severe. A crew member boarded the lifeboat anyway, and the lifeboat slipped 2 feet creating a hazardous situation for the crew member. The crew also stated the 2 inboard (Stbd) lifeboats are installed the same way. 74 SOLAS 01 III/11.8
Condition: Improper Installation
Action required: 30 - Ship detained
Due 27 September 2022
Resolved 27 September 2022
Resolution: New, shorter tricing pendants were installed to the davits, correcting the deficiency. Deficiency and detention removed.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 6 April 2022
Resolved
Fire protection systems and firefighting systems and appliances shall be maintained ready for use. PSCO observed that ampule in the sprinkler head was not in the condition it was designed, it contained half the fluid required.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2022
Resolution: Fixed while inspectors onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 April 2022
Resolved
Illustration and instruction in appropriate language shall be posted at muster stations to inform passengers the method of donning lifejackets. PSCO observed no instructions for donning of lifejackets in muster stations A nor B.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 6 April 2022
Resolved
Posters or signs shall be provided on or in the vicinity of survival craft and their launching controls and shall be easily seen under emergency lighting condition. PSCO observed missing emergency lights in vicinity of lifeboat launching instructions.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2022
Resolved 9 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 6 April 2022
Resolved
All lifesaving appliances and arrangements shall comply with the applicable requirements of the Code. The enclosure shall be so arranged that hand rails provide a secure handhold for persons moving about the exterior of the lifeboat, and aid embarkation and disembarkation. PSCO observed a broken bracket on the handrail on lifeboats 1 and 2.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2022
Resolved 9 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 6 April 2022
Resolved
Containers, brackets, racks, and other similar stowage locations for life-saving equipment shall be marked in acordance with the recommendations of the organization. PSCO observed lighted buoy with incorrect marking.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 April 2022
Resolution: Fixed while inspectors onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 6 April 2022
Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. Every life boat shall consist of an operational compass which is luminous or provided with suitable means of illumination. PSCO observed that the light used to read the compass was not operating in life boats 2 and 4.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2022
Resolved 9 April 2022
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 6 April 2022
Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photo luminescent strip indicators placed not more than 300mm above the deck at all points of the escape route, including angles and intersections. Additionally, all escape route signs and fire equipment location markings shall be of photo luminescent material or marked by lighting. Throughout the decks accessible to passengers, there were multiple sections of photo lumonescent material not marked to identify direction of escape, fire stations, and muster stations.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 6 April 2022
Resolution: Fixed while inspectors onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 6 April 2022
Resolved
An International Oil Pollution Prevention Certificate shall be issued, after an initial or renewal survey to any ships of 400 GT and above which are engaged in voyages to ports or offshore terminals under the jurisdiction of other Parties to the present Convention. PSCO observed the IOPP supplement did not have the correct throughput of the OWS.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 April 2022
Resolution: Fixed while inspector onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 October 2020
Resolved
All of vessel's statutory documentation is expired due to layup and under survey status per Bureau Veritas. This conflicts with Bahamas lay up status approval and CVC work instruction -018(1)
Site: Resolution A.1052(27)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 April 2022
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 October 2018
Resolved
Below the bulkhead deck there shall be two means of escape, at least one of which shall be independent of watertight doors and shall be provided from each watertight compartment, or similarly restricted space or group of spaces. The workshop and HVAC room#2 does not meet this requirement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 December 2018
Resolution: Received class report stating space is no longer a workshop.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 October 2018
Resolved
Life Saving Appliances and arrangements required by this chapter shall be approved by the administration. The vessels LSA plan has not been approved by the vessels administration.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 December 2018
Resolution: Plan approved by Flag, awaiting approval from MSC. Updated to rectify within 30 days.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 29 October 2018
Resolved
In ships carrying more than 36 passengers, plans and booklets required by this regulation shall provided information regarding fire protection, fire detection and fire extinction based on guidelines developed by the organization. The vessels fire control plan has not been reviewed and approved by the organization.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 December 2018
Resolution: Plan approved by the organization, awaiting approval from MSC. Updated to rectify within 30 days.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 October 2018
Resolved
Life Saving Appliances and arrangements required by this chapter shall be approved by the administration. The vessels LSA plan has not been approved by the vessels administration. Plan shall be approved prior to the carriage of passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2019
Resolved 16 January 2019
Resolution: MSC approved (see docs)
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 29 October 2018
Resolved
In ships carrying more than 36 passengers, plans and booklets required by this regulation shall provided information regarding fire protection, fire detection and fire extinction based on guidelines developed by the organization. The vessels fire control plan has not been reviewed and approved by the organization. Plan shall be approved prior to the carriage of passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2019
Resolved 16 January 2019
Resolution: MSC approved (see docs)
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 August 2018
Resolved
Below the bulkhead deck there shall be two means of escape, at least one of which shall be independent of watertight doors and shall be provided from each watertight compartment, or similarly restricted space or group of spaces. - The workshop and HVAC room #2 does not meet this requirement.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2018
Resolved 16 May 2019
Resolution: Cleared by MSC
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 4 August 2018
Resolved
Life Saving Appliances and arrangements required by this chapter shall be approved by the administration. The vessels LSA plan has not been approved by the vessels administration.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2018
Resolved 16 May 2019
Resolution: Approved by Administration and MSC.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 4 August 2018
Resolved
In ships carrying more than 36 passengers, plans and booklets required by this regulation shall provided information regarding fire protection, fire detection and fire extinction based on guidelines developed by the organization. The vessels fire control plan has not been reviewed and approved by the organization.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2018
Resolved 16 May 2019
Resolution: Observed presence of approved fire control plan.