13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 December 2025
Resolved
S and L vessels shall be provided with bilge pumps in accordance with table 182.25-10(a). Fire pump is being used as secondary bilge pump and does not have adequate suction (50GPM).46CFR182.25-10
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 December 2025
Resolution: Crew conducted training and secondary bilge pump now functions
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 December 2025
Resolved
Mechanically propelled "S" vessels with over 49 passengers shall comply with sub-chapter f of this chapter. Multiple non-metallic hoses have been installed in main fire system. Renew to metallic material.46CFR182.40-5(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 December 2025
Resolution: All non-metallic hoses removed and replaced with galvanized steel
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 December 2025
Resolved
Rigid non-metallic materials are acceptable for use in bilge system. Bilge system is constructed of metallic material with soft patches throughout. Renew system to original design.46CFR182.40-5(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 December 2025
Resolution: All non-metallic piping removed and replaced with galvanized steel
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 December 2025
Resolved
Through hull fittings and shutoff valves shall be metal.
-Soft patch in bilge system on hull fitting on discharge side of non-return valve.
-shutoff valve is seized and can not be secured
46CFR182.40-1(a)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 December 2025
Resolution: Valve replaced and softpatch removed and replaced with steel
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 December 2025
Resolved
All electrical installations shall be to the satisfaction of the OCMI. The generator would not start, repair generator.
46CFR183.01-15(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 December 2025
Resolution: Generator repaired and now functions
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 December 2025
Resolved
The owner/master shall instruct the crew member at least every 3 months on duties they are expected to perform in an emergency. Crew did not know how to use secondary bilge pump. Complete crew training. 46CFR185.420(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 December 2025
Resolution: Captain conducted training with all crew on bilge pump function
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 December 2025
Resolved
Electrical equipment on a vessel must be installed to protect crew and passengers. Multiple extension chords on vessel "daisy chained" and exposed to elements on top deck and in galley. Remove extension chords. 46CFR183.200(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 December 2025
Resolution: all extension chords removed from vessel
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 December 2025
Resolved
A vessel is inspected for compliance with the standards required by this sub chapter. Machinery, equipment, materials, and arrangements not covered by standards in this sub chapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice.
-MDG not in use has fuel in filters/piping. Remove fuel from system.
-Port and stbd MDE have sediment in fuel filters, clean or replace filters.
-Sea strainers for MDE have sediment. Clean or replace filters.
46CFR176.800(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 January 2026
Resolution: Vessel cleaned or replaced filters
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 8 December 2025
Resolved
Vessels bilge alarm indicators were faded and it was not clear which one indicated which space. Replace labels.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 January 2026
Resolution: Vessel re-labeled bilge high level alarms
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 December 2025
Resolved
Power driven vessels 20 meters or longer must have a bridge to bridge certificate documenting the bridge to bridge radiotelephone station is inspected in accordance with the Bridge to Bridge act. 47CFR 80.1001
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 January 2026
Resolution: Vessel received bridge to bridge
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 December 2025
Resolved
U.S. passenger vessels carrying more than six passengers is required to be inspected and hold a FCC safety certificate and a FCC Station license. Vessel only holds a station license. 47 CFR 80.903
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 January 2026
Resolution: Vessel received a safety certificate and station license
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 December 2025
Resolved
Vessels subject to the radiotelephone act must have one designated radio operator with a valid FCC Marine Radio Operator Permit (MROP). Vessel's operator did not have a FCC MROP. 47CFR 80.155.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 January 2026
Resolution: Vessels master provided MROP
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 8 December 2025
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 December 2025
Resolution: Captain received medical certificate
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 December 2025
Resolved
Vessels life jackets must be marked in accordance with 46CFR164.018. Retro reflective tape was worn and no longer serviceable. Approx 80 adult life jackets and 4 children remain in good condition, vessel is restricted to 80 adult passengers. 46CFR185.604
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 December 2025
Resolution: Retroflective tape applied to all lifejackets
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 December 2025
Resolved
Vessel is required to have a first aid kit with the contents listed in 46 CFR 160.045-4. Vessels first aid kit was spent and missing ammonia inhalants, asprin, tourniquet, eye dressing packet. Replace and provide picture / receipt to the OCMI. 46CFR 184.710.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 January 2026
Resolution: Vessel restocked first aid kit
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 December 2025
No resolution recorded
Marine employers must ensure crew in safety sensitive positions must ensure crew are enrolled in a USCG accepted Drug and Alcohol Testing program in accordance with 46 CFR 16.230 for pre employment testing, probable cause, random testing and post marine casualty testing. Vessels program appeared to be an enrollment letter hand written with the majority of the crew labeled exempt. Random tests were not identified and the enrollment letter stated it was for the holders of CDL's and listed DOT requirements and not USCG requirements.Submit to a DAPI audit with the local USCG office within 30 days. 46 CFR 16.230.
Action required: 50 - Rectify deficiencies w/in 30 days
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 December 2025
Resolved
The marine employer is required to be able to test all crew members for alcohol within 2 hours. Vessel did not have alcohol swabs or a means to test crew members for alcohol within the alloted time frame. 46 CFR 16.240.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 January 2026
Resolution: Vessel has an alcohal testing device
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 December 2025
Resolved
Vessels aft port quarter was found with areas weakened due to rot, and an area of rot was found on railing. Submit repair plan/proposal for approval
Vessels overhead on the main deck over the stairway was found falling and held by duct tape, submit repair plan / proposal for approval
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 January 2026
Resolution: Vessel conducted satisfactory repairs
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 24 March 2025
Resolved
Clear excess equipment from firestation #2. To be rectified by 29 April 2025.
Cite: 46 CFR 181.15-5(c) (Old-T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2025
Resolved 16 April 2025
Resolution: Gear was removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 March 2025
Resolved
Relocate the spare battery and engine oil that are being
stored in the walk in reefer. To be rectified by 29 April 2025.
Cite: 46 CFR 182.818
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2025
Resolved 16 April 2025
Resolution: Gear was removed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 March 2025
Resolved
Repair or replace the pressure gauge on the fire pump. To be rectified by 15 May 2025.
Cite: 46 CFR 181.10-1(c) (Old-T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2025
Resolved 24 April 2025
Resolution: New gauge was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 March 2025
Resolved
Provide evidence of the internal volume of the galley pressure vessel for the potable water system. To be rectified by 15 May 2025.
Cite: 46 CFR 182.330
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2025
Resolved 16 April 2025
Resolution: Pressure vessel is 36 gallons (approximately 4.8 cuft).
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 March 2025
Resolved
Vessel is past due for its annual inspection.
Cite: 46 CFR 176.502.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 April 2025
Resolution: Completed Annual Inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 March 2024
Resolved
STBD propulsion engine did not clutch in. Vessel is to provide a technician report and repair plan prior to repairs. Upon completion of repair USCG Marine Inspector is to verify operations while underway.
46CFR182.05-5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2024
Resolution: Completed operational tests in San Diego harbor. All SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 March 2024
Resolved
Port side propulsion engine's rubber coupling appears to be failing. Vessel is to provide a technician report or remove coupling for USCG Marine Inspector to observe. Upon completion of repair USCG Marine Inspector is to verify operations while underway.
46CFR182.05-5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2024
Resolution: Observed rubber coupling after vessel's mechanic review and saw no issues; however, vessel is planning to replace coupling. All SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 March 2024
Resolved
Observed an unauthorized temporary repair on the port side forward of the engine room for the fuel oil return. Vessel is to make permanent repairs.
46CFR182.20-40
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2024
Resolution: Observed permanent repairs
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 March 2024
Resolved
Observed an unauthorized temporary repair on the STBD Side at the fuel oil (FO) cut-out valve to the FO tank . Vessel is to make permanent repairs.
46CFR182.20-40
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2024
Resolution: Observed permanent repairs to STBD FO COV
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 March 2024
Resolved
Boarding ladder for passenger's is not safe for use. Vessel is replace the boarding ladder or provide a repair proposal prior to making any repairs.
46CFR177.100
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2024
Resolution: Observed repairs to boarding ladder hand rails, all SAT
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 March 2024
Resolved
Water tight door (WTD) does not seal in the engine room. Vessel is to adjust or make repairs for the door to seal properly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2024
Resolution: Observed WTD for proper sealing, all SAT
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 March 2024
Resolved
First aid kit has expired solutions and is not fully stocked. Vessel is to replace first aid kit, IAW 46CFR160.041.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2024
Resolution: Obsevered first aid kit. All SAT
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 March 2024
Resolved
Galley does not have a fire extinguishing system for the galley hood. Vessel is to install a fixed firefighting system or condemn the use of the galley in regards to cooking. A letter of intent not to use the galley shall be provided.
Action required: 705 - Other - as specified
Resolved 26 February 2026
Resolution: Vessel does not use galley.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 25 March 2024
Resolved
Vessel does not have GPS installed into VHF radio. Vessel is to provide a means to have GPS incorporated into the VHF radio.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2024
Resolved 9 May 2024
Resolution: Observed new VHF radio, function test (GPS and MMSI). All SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 March 2024
Resolved
Observed an unauthorized hose to the STBD propulsion engine's cooling system. Vessel is to replace the hose, as per manufactures specifications.
46CFR182.05-5
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 May 2024
Resolution: Observed new hose and tested for leaks. All SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 March 2024
Resolved
Observed both propulsion engine OVBD exhaust breathers (1" hose) to the stern discharge are loose. Vessel is to make hoses sea worthy.
46CFR182.05-5
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 May 2024
Resolution: Observed double hose clamp OVBD exahaust breathers. All SAT
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 25 March 2024
Resolved
Observed both rudder indicators are not operational at the operation station and locally. Vessel make repairs prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2024
Resolved 9 May 2024
Resolution: Observed operation tests of rudder indicators. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2024
Resolved
Junction box on upper deck is weather tight. Vessel is to make junction box weather tight.
46CFR183.10-20
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2024
Resolution: Observed juction box is weather sealed. All SAT
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 16 March 2023
Resolved
Engine room water tight door closing mechanism does not properly secure upper and lower latch to secure door. Repair door closing mechanism to the satisfaction of the CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2023
Resolved 11 April 2023
Resolution: Verified; [name withheld].
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 March 2023
Resolved
STBD side main deck fire hose station supply valve stem
retaining nut seized in the open position allowing water to leak pass valve stem. Repair supply valve to the
to the satisfaction of the CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2023
Resolved 3 April 2023
Resolution: Verified STBD Hose station supply valve and its nozzle; ALL SAT.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 16 March 2023
Resolved
Interior Communication Public Address system not
operable from second deck. Repair Public address system
to the satisfaction of the CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2023
Resolved 3 April 2023
Resolution: Verified PA system operational; ALL SAT
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2023
Resolved
Engine room start air compressor controller not properly
sealed from bottom of enclosure. Install approved knock-
out seals to the satisfaction of the CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2023
Resolved 16 March 2023
Resolution: Received picture of corrected item.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 March 2023
Resolved
Engine room SWBD panel Hertz meter reading 57.5 HZ;
while on No. 1 Generator. Confirm calibration of hertz
meter to the satisfaction of the CG Marine Inspector.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2023
Resolved 3 April 2023
Resolution: verified HZ Meter operational while on ship's generator power; ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 March 2023
Resolved
Engine room SWBD panel green power available light indicator for generator and shore power inoperable. Repair to the satisfaction of the CG Marine
Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2023
Resolved 11 April 2023
Resolution: Installed & operational; [name withheld]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 March 2023
Resolved
Engine room Switchboard panel: circuit breaker nameplate label on No.1 generator breaker (225A) not properly
Indicating actual breaker ampacity (125A). Provide proper label.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2023
Resolved 28 March 2023
Resolution: Received picture of corrected item.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 March 2023
Resolved
STBD main engine exhaust system flex piping missing double hose clamp. Install approved clamps to the satisfaction of the CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2023
Resolved 16 March 2023
Resolution: Received picture of corrected item.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2023
Resolved
Upper deck electrical outlet junction boxes not permanently mounted. Permanently mount to the satisfaction of the CG Marine Inspector.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2023
Resolved 25 March 2024
Resolution: Junction box is permanently installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 March 2023
Resolved
STBD upper deck ring buoy weathered. Replace in kind to
the satisfaction of the CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2023
Resolved 28 March 2023
Resolution: Received picture of life ring buoy replacement.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 16 March 2023
Resolved
First aid kit pain medication not in inventory. Provide
pain medication replacement to inventory.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2023
Resolved 16 March 2023
Resolution: Received picture of corrected item.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 January 2023
Resolved
Vessels dry dock was due as of 31DEC2022. Vessel is prohibited from taking passengers until credit dry dock is given.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2023
Resolution: Credit DDX/ISE given this date.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 January 2023
Resolved
Vessels railing must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction and 50 pounds per foot applied to the top rail in any direction. Multiple sections of the railing were found with extensive termite damage and wood rot.
Vessel must remove all; panels on railing, benches along railing and to expose existing structures and make available for inspection for USCG marine inspectors.
Vessel must submit plans for review and approval of replacing known areas of termite damage and wood rot prior to repairs being initiated.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 February 2023
Resolution: Only the cap pieces were found to had significant damage. A new worklist item will replace this one.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 20 January 2023
Resolved
Deck flooring was significantly warped due to water damage to the point of causing a slip, trip and fall hazard to passengers. Remove flooring and if allowed make top aluminum of deck available for inspection.
Submit repair proposals to make floor less hazardous.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2023
Resolution: Laminate deck covering removed. Owner plans to remove glue and paint deck without installing new laminate deck covering.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2022
Resolved
Electrical cable run between fire pump and motor controller not protected from chaffing and sharp edges.
Repair to satisfaction of CG.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2022
Resolved 3 May 2022
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2022
Resolved
Identified 2 inch hole in bottom of Main Engine room SWBD panel not properly sealed; Repair to satisfaction of CG
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2022
Resolved 3 May 2022
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2022
Resolved
Electrical power cable enter fire pump electrical J-box missing cable connector; Repair to satisfaction of CG.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2022
Resolved 3 May 2022
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2022
Resolved
Engine room battery banks not properly secured from movement. Must provide proper securing from movement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2022
Resolved 3 May 2022
Resolution: Corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2022
Resolved
On Main Engine wet exhaust system; identified PVC pipe installation on stbd main engine. Must replace with approved flex hose to satisfaction of CG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2022
Resolved 28 June 2022
Resolution: Pictures sent as proof rectifying deficiency...[name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2022
Resolved
Portside forward compartment light fixture diffuser missing. Must make repair to satisfaction of CG.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2022
Resolved 3 May 2022
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 30 March 2022
Resolved
ADEQUATE EMERGENCY LIGHTING AUTOMACTICALLY ACTUATED UPON FAILURE OF THE MAIN LIGHTING SYSTEM SHALL BE FITTED ALONG THE LINE OF ESCAPE. VESSELS NOT EQUIPPED WITH A SINGLE SOURCE E LIGHTING SYSTEM SHALL HAVE INDIVIDUAL BATTERY POWERED AUTO OPERATED LIGHTS IN STRATEGIC LOCATIONS AND SHALL HAVE CAPACITY FOR 6 HOURS OF CONTINUOUS OPERATION.
E LIGHING THROUGHOUT THE VESSEL WAS INOPERABLE AT TIME OF INSPECTION.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2022
Resolution: Verified by [name withheld]
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 March 2022
Resolved
ALL PORTABLE EXTINGUISHERS AND SEMI PORTABLE SYSTEMS SHALL BE CHECKED ANNUALLY AS REQUIRED.
ALL OF THE VESSELS PORTABLE FIRE EXTIGUISHERS ARE OVERDUE FOR ANNUAL SERVICING.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2022
Resolution: Verified by [name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2022
Resolved
ELECTRICAL INSTALLATIONS AND EQUIPMENT SHALL BE SAFE FROM FIRE CAUSED BY AND/OR ORIGINATING IN ELECTRICAL EQUIPMENT AND SAFE FROM ELECTRICAL SHOCK OF PERSONNEL.
ELECTRICAL JUNCTION BOXES FOR INSTALLED FIRE PUMP POWER SUPPLY ARE SEVERLY CORRODED WITH OPENINGS ALLOWING WATER TO ENTER BOX.
REPLACE BROKEN LIGHT COVER OVER STARBOARD MAIN ENGINE TO PREVENT FIRE CAUSED BY ELECTRICAL EQUIPMENT.
PROPERLY MOUNT ELECTRICAL JUNCTION BOX FLOATING IN OVERHEAD NEAR ENGINE ROOM WATERTIGHT DOOR.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2022
Resolution: Verfied by [name withheld]
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2022
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 30 March 2022
Resolved
Self propelled vessel of >65' in commercial service must have operational Coast Guard type-approved AIS Class A device.
--Vessel does not have operational AIS device onboard. Install and coordinate USCG attendance to clear.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2022
Resolved 2 December 2022
Resolution: VSL INSTALLED AIS
05 - Radio Communications › N/A - No Subsystem › SART/AIS-SART
Issued 30 March 2022
Resolved
Self propelled vessels of over 65ft in commercial service mus have an operational CG approved AIS type A device.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2022
Resolved 2 December 2022
Resolution: VSL INSTALLED AIS
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 March 2021
Resolved
Make the following wiring changes or revisions to the A/C 1-line drawing:
1. List all spare breakers in 1-line drawing;
2. Disconnect and terminate 220V heater outlet on starboard panel;
3. Provide Amp draw (or horsepower) for fire pump installed on port panel.
Due no later than 18 May 2021.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2021
Resolved 17 June 2021
Resolution: Verified deficiencies recitified to the satisfaction of the attending MI.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 January 2021
Resolved
Install UL 1104 approved stern light. Due 25Feb2021
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 February 2021
Resolved 16 March 2021
Resolution: Replaced.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 23 December 2020
Resolved
Service discharged fire extinguisher (bar location) prior to operating commercially.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 December 2020
Resolution: Serviced.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 December 2020
Resolved
Repair fuel shutoff valve pull handle prior to operating commercially.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 December 2020
Resolution: Fuel shutoff valve repaired.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 23 December 2020
Resolved
Replace expired distress signals prior to operating at night and no later than 23Jan2021.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 January 2021
Resolved 28 December 2020
Resolution: Replaced distress signals.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 23 December 2020
Resolved
Program VHF radio with vessel details (MMSI and other info) for DSC communications, due 23Jan2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 January 2021
Resolved 21 January 2021
Resolution: Programmed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 December 2020
Resolved
Remove temporary wiring (extension cords and outlet extensions) from upper deck, starboard side. Due 23Jan2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 January 2021
Resolved 21 January 2021
Resolution: Removed.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 23 December 2020
Resolved
Properly brace refrigerator in galley form shifting while underway. Due 23Jan2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 January 2021
Resolved 21 January 2021
Resolution: Braced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 December 2020
Resolved
Install panel cover on generator hours counter junction box, due 23Jan2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 January 2021
Resolved 21 January 2021
Resolution: Installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 December 2020
Resolved
Install pipe hangars on fire main piping in way of fire pump, due 23Jan2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 January 2021
Resolved 21 January 2021
Resolution: Installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 December 2020
Resolved
Remove excess foam and debris from machinery space, due 23Jan2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 January 2021
Resolved 21 January 2021
Resolution: Installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 23 December 2020
Resolved
Prove operation of generator remote start/stop. Due 23Jan2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 February 2021
Resolution: Video provided of engine start/stop.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 December 2020
Resolved
Provide product information and receipt for replacement stern light. Due 23Jan2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 January 2021
Resolution: Provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 December 2020
Resolved
Replace generator circuit breaker, not to exceed 140 amps (115% of generator full load rating), due 21Jan2021.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2021
Resolution: 125A CB installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 December 2020
Resolved
Lock/Tag out galley range and walk-in freezer pending electrical power/distribution system review. Due 23Jan2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 February 2021
Resolution: Equipment disconnected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 December 2020
Resolved
Provide electrical system load analysis and A/C 1-line diagram for all permanently installed equipment. Due 23Jan2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 January 2021
Resolved 4 May 2021
Resolution: 1-line provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 November 2020
Resolved
A dry-dock and internal structural examination must be completed by the due date of the Certificate of Inspection. Complete required inspections prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2020
Resolved 18 December 2020
Resolution: Completed DDX/ISE.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 4 February 2020
Resolved
Conduct underway drills and sea trial with licensed captain and crew.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 February 2020
Resolution: Witnessed underway drills and verified licensed master.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 February 2020
Resolved
Prove operation of fire pump.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 February 2020
Resolution: Tested fire pump, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 February 2020
Resolved
Prove operation of remote fuel cut-off valves.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 February 2020
Resolution: Operated remote fuel shut-offs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 February 2020
Resolved
Fasten lose propulsion shaft coupling bolts and torque to manufactures specification.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 February 2020
Resolution: Bolts were all torqued to specification.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 February 2020
Resolved
Provide vessel with valid FCC Safety and Station licenses.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 7 February 2020
Resolution: Vessel rep provided valid certificates.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 February 2020
Resolved
Label bilge alarms to corresponding compartments.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 7 February 2020
Resolution: Bilge alarms were labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 February 2020
Resolved
Remove power strip providing power to galley island refrigerator and provide permanent outlet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 7 February 2020
Resolution: Power strip was removed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 February 2020
Resolved
Provide vessel with UL 1104 approved stern light, as per Nav rule #23.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2020
Resolved 23 December 2020
Resolution: Stern light installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 4 February 2020
Resolved
Replace leaking salt water cooling pipe for port shaft v-drive.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2020
Resolved 3 March 2020
Resolution: Received photo of new replacement piping installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 January 2020
Resolved
All inspected small passenger vessels must undergo an annual inspection within the three months before or after each anniversary date on their Certificate of Inspection (COI). As of October 25, 2019, your vessel is past due on their COI annual inspection. Vessel is restricted from operating until a COI annual inspection has been completed by CG Marine Inspectors.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2020
Resolved 4 February 2020
Resolution: Commenced annual inspection, 04 no-sail defs issued.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 August 2018
Resolved
Install proper E/R ventilation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2018
Resolved 4 February 2020
Resolution: Metal flexible ducting was installed and plywood was removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2018
Resolved
Provide all DAPI paperwork for audit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 30 August 2018
Resolution: DAPI audit completed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 July 2018
Resolved
Post all pages of stability letter.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 14 August 2018
Resolution: Pages posted
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 July 2018
Resolved
Provide new FCC safety radio certificate
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 30 August 2018
Resolution: New FCC certificate provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2018
Resolved
Provide training and letter for senior deckhand.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 14 August 2018
Resolution: Letter provided.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 25 July 2018
Resolved
Provide updated light list for area of operations.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 14 August 2018
Resolution: Light list provided
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2018
Resolved
Provide proof of current first aid/CPR for 02 crew.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 14 August 2018
Resolution: Proof provided
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2018
Resolved
Post ship specific emergency instructions for crew.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 14 August 2018
Resolution: Instructions posted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2018
Resolved
Provide records of fire/MOB drills, and complete drills to USCG Marine Inspector
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 July 2018
Resolved 14 August 2018
Resolution: Records provided. Drills completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 July 2018
Resolved
Replace 01 life rings
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 30 August 2018
Resolution: New lifering provided and marked.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 25 July 2018
Resolved
Remove or fix additional non-functioning VHF radio
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 14 August 2018
Resolution: Old radio removed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 July 2018
Resolved
Remove or fix extra non-functioning fire detector in fwd accom below deck
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 14 August 2018
Resolution: Removed from vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2018
Resolved
Replace expired items in first aid kit
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 14 August 2018
Resolution: Items replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2018
Resolved
Remove paint cans and gasoline can found in fwd accom and in galley.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 14 August 2018
Resolution: All removed from vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2018
Resolved
Fix main deck light cover on stbd side.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 14 August 2018
Resolution: Cover fixed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 July 2018
Resolved
Fix retro on 07 lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 14 August 2018
Resolution: Retro fixed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2018
Resolved
Label emergency exits to main deck and clear clutter. Add ladder to exit from galley.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 14 August 2018
Resolution: Label and ladder added.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 25 July 2018
Resolved
Move extra fire extinguisher to fwd accom.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 25 July 2018
Resolution: Corrected on the spot.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 July 2018
Resolved
Prove proper integrity of watertight door.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 30 August 2018
Resolution: Watertight door chalk tested satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 July 2018
Resolved
Install open/closed indicator on operating stationg for WTD.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 30 August 2018
Resolution: Watertight door indicator installed properly.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 25 July 2018
Resolved
Fix dead end wires at plugged in wiring (galley lights). Hard wire lighting properly (UL listed)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 14 August 2018
Resolution: New permanent lighting installed.
Operations/Management › Drills/Instruction › Fire
Issued 15 May 2017
Resolved
Perform drills in CG presence
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2017
Fire Fighting › Fire Pumps › Power Source
Issued 15 May 2017
Resolved
Provide fire pump pressure gauge
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 30 August 2018
Resolution: Item not cleared from previous activity. Verified during recent COI inspection.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 May 2017
Resolved
Remove wire nuts from under bridge and provide proper connections
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 19 May 2017
Lifesaving › Lifebuoys › Immediately Available
Issued 15 May 2017
Resolved
Prove ring buoys are stowed in a readily accessible area
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2017
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 15 May 2017
Resolved
Provide distress signals
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2017
Fire Fighting › Means of Escape › Escape Route Signs
Issued 15 May 2017
Resolved
Label emergency exit near bridge
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 19 May 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 May 2017
Resolved
Remove unauthorized wiring from forward cabin
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 19 May 2017
Navigation › Piloting/Steering › Marine Charts
Issued 15 May 2017
Resolved
Provide current charts and publications
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 19 May 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 May 2017
Resolved
Provide aspirin and burn gel
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 19 May 2017
Engineering › Generator (propulsion/auxiliary-electric) › Measurement Circuitry
Issued 15 May 2017
Resolved
Provide Hertz meter for #1 generator
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 30 August 2018
Resolution: Item not cleared from previous activity. Verified during recent COI inspection.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 15 May 2017
Resolved
Remove flammable liquids from galley
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 19 May 2017
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 15 May 2017
Resolved
Remove excess battery from E/R
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 19 May 2017
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 15 May 2017
Resolved
Provide all drug and substance abuse program documentation (MIS Reports, supervisor training certificate, current crew list, etc)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2017
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 21 October 2016
Resolved
Submit modification plans for changing E/R overhead to aluminum
Action required: 705 - Other - as specified
Resolved 30 August 2018
Resolution: Item not cleared from previous activity. Verified during recent COI inspection.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 October 2016
Resolved
Properly lavel lifering
Action required: 705 - Other - as specified
Due 6 November 2016
Resolved 17 October 2016
Resolution: Lifering labeled
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 October 2016
Resolved
Prove proper operation of self igniting light
Action required: 705 - Other - as specified
Due 6 November 2016
Resolved 17 October 2016
Resolution: New battery installed. Operation sat.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 6 October 2016
Resolved
Service all portable fire extinguishers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2016
Resolution: All portable fire extinguishers serviced.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 October 2016
Resolved
Post COI in position viewable to passengers
Action required: 705 - Other - as specified
Due 6 November 2016
Resolved 17 October 2016
Resolution: COI posted in viewable postion.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 6 October 2016
Resolved
Make modifications to E/R overhead/reduce fire load in E/R
Action required: 705 - Other - as specified
Due 21 November 2016
Resolved 30 August 2018
Resolution: Item not cleared from previous activity. Verified during recent COI inspection.