MAURY USCG vessel records
← All vessels

ST. PETRI

ST. PETRI is a 2018 tank ship. The Coast Guard has recorded 12 inspections since 2019, most recently in September 2025, along with 6 deficiencies and 1 operational control.

Records from 2019 to 2025. Most recent: inspection, 29 September 2025.

Built
2018
Last inspected
29 September 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 September 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2019–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9788497
9V3777
1553936
Flag
SINGAPORE
Maury page id
psix-1553936

Documentation record

Tonnage as PSIX records it13762 - Convention (Subpart B), Net Ton
29513 - Convention (Subpart B), Gross Ton
50105 - Dead Weight, Ton
61126 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

29 September 2025 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8239535
25 September 2024 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8009063
24 September 2024 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8008732
21 September 2024 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8006646
21 July 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7748588
4 March 2023 COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7643224
3 May 2022 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7443120
2 December 2021 PSC B · COC-CHEM & TVE Annual · MARPOL Annex VI Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7358145
6 November 2020 COC-CHEM & TVE Renew · Ballast Water Examination · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7088606
8 August 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6776487
11 June 2019 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6717060
3 June 2019 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6695680

Deficiency record · 6

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 6 November 2020 Resolved
The company should establish procedures, plans, and instructions, including checklists as appropriate for key shipboard operations concerning the safety of the personnel, ship, and protection of the environment. The various tasks should be defined and assigned to qualified personnel. The following operations were found to lack procedures to maintain safety of the vessel: 1. Gas detection calibration 2. Gas detection testing for fixed gas detection system 3. ODME Testing 4. Cargo operations and monitoring of tank conditions; oxygen levels
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2020
Resolved 9 November 2020
Resolution: Verified additional ISM procedures for the required equipment.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 6 November 2020 Resolved
Tankers shall be equipped with at least one portable instrument for measuring flammable vapor concentrations, together with a sufficient set of spares. Suitable means shall be provided for the calibration of such instruments for measuring oxygen and flammable vapors concentration. Crew was unable to demonstrate proper calibration of equipment.
Action required: 10 - Deficiency Rectified
Resolved 6 November 2020
Resolution: Deficiency cleared prior to PSCO departure.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 6 November 2020 Resolved
Vessels installed with oil monitoring and control systems (ODME) shall ensure the ship staff training must include familiarization in the operation and maintenance of the equipment.
Action required: 10 - Deficiency Rectified
Resolved 6 November 2020
Resolution: Deficiency cleared prior to PSCO departure.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 6 November 2020 Resolved
Vessel shall be able to maintain the atmosphere in any part of any cargo tank with an oxygen content not exceeding 8% by volume and at a positive pressure at all times in port and at sea except when it is necessary for such a tank to be gas free. Multiple cargo tanks were found to have oxygen levels above 8% upon intry into the Port of Homer.
Action required: 10 - Deficiency Rectified
Resolved 6 November 2020
Resolution: Deficiency cleared prior to PSCO departure.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 November 2020 Resolved
Flares must be clearly marked with approval information, including the administration which approved it. The 12 parachute flares located on the bridge do not show approval by administration or appropriate governing body (IMO, USCG, MARAD).
Action required: 15 - Rectify deficiencies by next port
Resolved 9 November 2020
Resolution: Verified Rocket Parachute Flare approval meets SOLAS.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 6 November 2020 Resolved
The company should establish procedures, plans, and instructions including checklists as appropriate for key shipboard operations concerning the safety of the personnel and ship. Vessel was unable to provide proedures for testing of the fixed gas detection system. Vessel was also unable to successfully conduct a proper test of the system. Due to objective evidence from previous deficiencies and potential failure of SMS, recommend an external audit of cargo operation and related systems.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2020
Resolution: Received paperwork for the ISM audit with no additional remarks.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.